Solution Type Technical Instruction Sure Solution 1005429.1 : Sun Enterprise[TM] 10000: Decoding Component Numbering
PreviouslyPublishedAs 207551 Description This document shows how to decode the physical path of sbus cards, pci cards, and processors to their physical location in the Sun Enterprise[TM] 10000 platform. Steps to Follow Steps to Follow For example: /sbus@41,0/qec@1,20000/qe@3,0 /sbus@41 decodes to system board 0, sysio 1 Bus Freq Brd Type MHz Slot Name Model --- ---- ---- ---- -------------------------------- ---------------------- 3 SBus 25 0 fcaw/sd (block) FCW 3 SBus 25 0 SUNW,qfe SUNW,sbus-qfe 3 SBus 25 0 SUNW,qfe SUNW,sbus-qfe 3 SBus 25 0 SUNW,qfe SUNW,sbus-qfe 3 SBus 25 0 SUNW,qfe SUNW,sbus-qfe 3 SBus 25 1 QLGC,isp/sd (block) QLGC,ISP1000U 3 SBus 25 1 fcr/sd (block) FCE-1473-N 4 SBus 25 0 fcaw/sd (block) FCW 4 SBus 25 0 network SUNW,sbus-gem 4 SBus 25 1 QLGC,isp/sd (block) QLGC,ISP1000U 4 SBus 25 1 SUNW,qfe SUNW,sbus-qfe 4 SBus 25 1 SUNW,qfe SUNW,sbus-qfe 4 SBus 25 1 SUNW,qfe SUNW,sbus-qfe 4 SBus 25 1 SUNW,qfe SUNW,sbus-qfe 7 SBus 25 0 network SUNW,sbus-gem 8 SBus 25 0 fcaw/sd (block) FCW 8 SBus 25 0 SUNW,qfe SUNW,sbus-qfe 8 SBus 25 0 SUNW,qfe SUNW,sbus-qfe 8 SBus 25 0 SUNW,qfe SUNW,sbus-qfe 8 SBus 25 0 SUNW,qfe SUNW,sbus-qfe 8 SBus 25 1 QLGC,isp/sd (block) QLGC,ISP1000U As we can see under the column SLOT it reports always 0 or 1. This value is exactly the slot where the io card is install and not the IO Controller. To determine the IO Controller in which the driver is installed, it is necessary to match prtdiag info with /etc/path_to_inst info. If we search for qfe inside /etc/path_to_inst file, we obtain the output below:
Using the table below we can decode sbus@61 as: System This means that our qfe is on IO Controller 1 and qfe card is installed inside SLOT 0 of this IO Controller 8 SBus 25 0 SUNW,qfe ------------------------------------ Breaking down the the device id's can show you exactly where a IO device is located within the machine. For example: /sbus@41,0/qec@1,20000/qe@3,0 /sbus@41 decodes to system board 0, sysio 1 First, the value shown is a hex value containing 8 bits. This is how to inteprete those bits: 4 1 ------------ ---------- 0 1 00 00 01 - ---------- - A B C A => 1 = IO or 0 = PROC /qec@1 = sbus slot 1 Second, the info with the driver type also indicates which slot it's in: sbus slot number 0-1 Below is a cheat sheet to help you with IO and Processors id's. I/O Cards (PCI) Component Solaris POST Front Panel Cable Label System Board 0 sysbd 0 SB0 SB0 I/O Port 0 /pci@40,0 scard 0.0.0 PCI 0.0 PCI 0.0.0 I/O Port 2 /pci@41,0 scard 0.1.0 PCI 1.0 PCI 0.1.0 System Board 1 sysbd 1 SB1 SB1 I/O Port 0 /pci@44,0 scard 1.0.0 PCI 0.0 PCI 1.0.0 I/O Port 2 /pci@45,0 scard 1.1.0 PCI 1.0 PCI 1.1.0 System Board 2 sysbd 2 SB2 SB2 I/O Port 0 /pci@48,0 scard 2.0.0 PCI 0.0 PCI 2.0.0 I/O Port 2 /pci@49,0 scard 2.1.0 PCI 1.0 PCI 2.1.0 System Board 3 sysbd 3 SB3 SB3 I/O Port 0 /pci@4c,0 scard 3.0.0 PCI 0.0 PCI 3.0.0 I/O Port 2 /pci@4d,0 scard 3.1.0 PCI 1.0 PCI 3.1.0 System Board 4 sysbd 4 SB4 SB4 I/O Port 0 /pci@50,0 scard 4.0.0 PCI 0.0 PCI 4.0.0 I/O Port 2 /pci@51,0 scard 4.1.0 PCI 1.0 PCI 4.1.0 System Board 5 sysbd 5 SB5 SB5 I/O Port 0 /pci@54,0 scard 5.0.0 PCI 0.0 PCI 5.0.0 I/O Port 2 /pci@55,0 scard 5.1.0 PCI 1.0 PCI 5.1.0 System Board 6 sysbd 6 SB6 SB6 I/O Port 0 /pci@58,0 scard 6.0.0 PCI 0.0 PCI 6.0.0 I/O Port 2 /pci@59,0 scard 6.1.0 PCI 1.0 PCI 6.1.0 System Board 7 sysbd 7 SB7 SB7 I/O Port 0 /pci@5c,0 scard 7.0.0 PCI 0.0 PCI 7.0.0 I/O Port 2 /pci@5d,0 scard 7.1.0 PCI 1.0 PCI 7.1.0 System Board 8 sysbd 8 SB8 SB8 I/O Port 0 /pci@60,0 scard 8.0.0 PCI 0.0 PCI 8.0.0 I/O Port 2 /pci@61,0 scard 8.1.0 PCI 1.0 PCI 8.1.0 System Board 9 sysbd 9 SB9 SB9 I/O Port 0 /pci@64,0 scard 9.0.0 PCI 0.0 PCI 9.0.0 I/O Port 2 /pci@65,0 scard 9.1.0 PCI 1.0 PCI 9.1.0 System Board 10 sysbd 10 SB10 SB10 I/O Port 0 /pci@68,0 scard 10.0.0 PCI 0.0 PCI 10.0.0 I/O Port 2 /pci@69,0 scard 10.1.0 PCI 1.0 PCI 10.1.0 System Board 11 sysbd 11 SB11 SB11 I/O Port 0 /pci@6c,0 scard 11.0.0 PCI 0.0 PCI 11.0.0 I/O Port 2 /pci@6d,0 scard 11.1.0 PCI 1.0 PCI 11.1.0 System Board 12 sysbd 12 SB12 SB12 I/O Port 0 /pci@70,0 scard 12.0.0 PCI 0.0 PCI 12.0.0 I/O Port 2 /pci@71,0 scard 12.1.0 PCI 1.0 PCI 12.1.0 System Board 13 sysbd 13 SB13 SB13 I/O Port 0 /pci@74,0 scard 13.0.0 PCI 0.0 PCI 13.0.0 I/O Port 2 /pci@75,0 scard 13.1.0 PCI 1.0 PCI 13.1.0 System Board 14 sysbd 14 SB14 SB14 I/O Port 0 /pci@78,0 scard 14.0.0 PCI 0.0 PCI 14.0.0 I/O Port 2 /pci@79,0 scard 14.1.0 PCI 1.0 PCI 14.1.0 System Board 15 sysbd 15 SB15 SB15 I/O Port 0 /pci@7c,0 scard 15.0.0 PCI 0.0 PCI 15.0.0 I/O Port 2 /pci@7d,0 scard 15.1.0 PCI 1.0 PCI 15.1.0 I/O Cards (Sbus) Component Solaris POST Front Panel Cable Label System Board 0 sysbd 0 SB0 SB0 I/O Port 0 /sbus@40,0 scard 0.0.0 SBUS 0 SLOT 0 SB 0.0.0 I/O Port 1 /sbus@40,0 scard 0.0.1 SBUS 0 SLOT 1 SB 0.0.1 I/O Port 2 /sbus@41,0 scard 0.1.0 SBUS 1 SLOT 0 SB 0.1.0 I/O Port 3 /sbus@41,0 scard 0.1.1 SBUS 1 SLOT 1 SB 0.1.1 System Board 1 sysbd 1 SB1 SB1 I/O Port 0 /sbus@44,0 scard 1.0.0 SBUS 0 SLOT 0 SB 1.0.0 I/O Port 1 /sbus@44,0 scard 1.0.1 SBUS 0 SLOT 1 SB 1.0.1 I/O Port 2 /sbus@45,0 scard 1.1.0 SBUS 1 SLOT 0 SB 1.1.0 I/O Port 3 /sbus@45,0 scard 1.1.1 SBUS 1 SLOT 1 SB 1.1.1 System Board 2 sysbd 2 SB2 SB2 I/O Port 0 /sbus@48,0 scard 2.0.0 SBUS 0 SLOT 0 SB 2.0.0 I/O Port 1 /sbus@48,0 scard 2.0.1 SBUS 0 SLOT 1 SB 2.0.1 I/O Port 2 /sbus@49,0 scard 2.1.0 SBUS 1 SLOT 0 SB 2.1.0 I/O Port 3 /sbus@49,0 scard 2.1.1 SBUS 1 SLOT 1 SB 2.1.1 System Board 3 sysbd 3 SB3 SB3 I/O Port 0 /sbus@4c,0 scard 3.0.0 SBUS 0 SLOT 0 SB 3.0.0 I/O Port 1 /sbus@4c,0 scard 3.0.1 SBUS 0 SLOT 1 SB 3.0.1 I/O Port 2 /sbus@4d,0 scard 3.1.0 SBUS 1 SLOT 0 SB 3.1.0 I/O Port 3 /sbus@4d,0 scard 3.1.1 SBUS 1 SLOT 1 SB 3.1.1 System Board 4 sysbd 4 SB4 SB4 I/O Port 0 /sbus@50,0 scard 4.0.0 SBUS 0 SLOT 0 SB 4.0.0 I/O Port 1 /sbus@50,0 scard 4.0.1 SBUS 0 SLOT 1 SB 4.0.1 I/O Port 2 /sbus@51,0 scard 4.1.0 SBUS 1 SLOT 0 SB 4.1.0 I/O Port 3 /sbus@51,0 scard 4.1.1 SBUS 1 SLOT 1 SB 4.1.1 System Board 5 sysbd 5 SB5 SB5 I/O Port 0 /sbus@54,0 scard 5.0.0 SBUS 0 SLOT 0 SB 5.0.0 I/O Port 1 /sbus@54,0 scard 5.0.1 SBUS 0 SLOT 1 SB 5.0.1 I/O Port 2 /sbus@55,0 scard 5.1.0 SBUS 1 SLOT 0 SB 5.1.0 I/O Port 3 /sbus@55,0 scard 5.1.1 SBUS 1 SLOT 1 SB 5.1.1 System Board 6 sysbd 6 SB6 SB6 I/O Port 0 /sbus@58,0 scard 6.0.0 SBUS 0 SLOT 0 SB 6.0.0 I/O Port 1 /sbus@58,0 scard 6.0.1 SBUS 0 SLOT 1 SB 6.0.1 I/O Port 2 /sbus@59,0 scard 6.1.0 SBUS 1 SLOT 0 SB 6.1.0 I/O Port 3 /sbus@59,0 scard 6.1.1 SBUS 1 SLOT 1 SB 6.1.1 System Board 7 sysbd 7 SB7 SB7 I/O Port 0 /sbus@5c,0 scard 7.0.0 SBUS 0 SLOT 0 SB 7.0.0 I/O Port 1 /sbus@5c,0 scard 7.0.1 SBUS 0 SLOT 1 SB 7.0.1 I/O Port 2 /sbus@5d,0 scard 7.1.0 SBUS 1 SLOT 0 SB 7.1.0 I/O Port 3 /sbus@5d,0 scard 7.1.1 SBUS 1 SLOT 1 SB 7.1.1 System Board 8 sysbd 8 SB8 SB8 I/O Port 0 /sbus@60,0 scard 8.0.0 SBUS 0 SLOT 0 SB 8.0.0 I/O Port 1 /sbus@60,0 scard 8.0.1 SBUS 0 SLOT 1 SB 8.0.1 I/O Port 2 /sbus@61,0 scard 8.1.0 SBUS 1 SLOT 0 SB 8.1.0 I/O Port 3 /sbus@61,0 scard 8.1.1 SBUS 1 SLOT 1 SB 8.1.1 System Board 9 sysbd 9 SB9 SB9 I/O Port 0 /sbus@64,0 scard 9.0.0 SBUS 0 SLOT 0 SB 9.0.0 I/O Port 1 /sbus@64,0 scard 9.0.1 SBUS 0 SLOT 1 SB 9.0.1 I/O Port 2 /sbus@65,0 scard 9.1.0 SBUS 1 SLOT 0 SB 9.1.0 I/O Port 3 /sbus@65,0 scard 9.1.1 SBUS 1 SLOT 1 SB 9.1.1 System Board 10 sysbd 10 SB10 SB10 I/O Port 0 /sbus@68,0 scard 10.0.0 SBUS 0 SLOT 0 SB 10.0.0 I/O Port 1 /sbus@68,0 scard 10.0.1 SBUS 0 SLOT 1 SB 10.0.1 I/O Port 2 /sbus@69,0 scard 10.1.0 SBUS 1 SLOT 0 SB 10.1.0 I/O Port 3 /sbus@69,0 scard 10.1.1 SBUS 1 SLOT 1 SB 10.1.1 System Board 11 sysbd 11 SB11 SB11 I/O Port 0 /sbus@6c,0 scard 11.0.0 SBUS 0 SLOT 0 SB 11.0.0 I/O Port 1 /sbus@6c,0 scard 11.0.1 SBUS 0 SLOT 1 SB 11.0.1 I/O Port 2 /sbus@6d,0 scard 11.1.0 SBUS 1 SLOT 0 SB 11.1.0 I/O Port 3 /sbus@6d,0 scard 11.1.1 SBUS 1 SLOT 1 SB 11.1.1 System Board 12 sysbd 12 SB12 SB12 I/O Port 0 /sbus@70,0 scard 12.0.0 SBUS 0 SLOT 0 SB 12.0.0 I/O Port 1 /sbus@70,0 scard 12.0.1 SBUS 0 SLOT 1 SB 12.0.1 I/O Port 2 /sbus@71,0 scard 12.1.0 SBUS 1 SLOT 0 SB 12.1.0 I/O Port 3 /sbus@71,0 scard 12.1.1 SBUS 1 SLOT 1 SB 12.1.1 System Board 13 sysbd 13 SB13 SB13 I/O Port 0 /sbus@74,0 scard 13.0.0 SBUS 0 SLOT 0 SB 13.0.0 I/O Port 1 /sbus@74,0 scard 13.0.1 SBUS 0 SLOT 1 SB 13.0.1 I/O Port 2 /sbus@75,0 scard 13.1.0 SBUS 1 SLOT 0 SB 13.1.0 I/O Port 3 /sbus@75,0 scard 13.1.1 SBUS 1 SLOT 1 SB 13.1.1 System Board 14 sysbd 14 SB14 SB14 I/O Port 0 /sbus@78,0 scard 14.0.0 SBUS 0 SLOT 0 SB 14.0.0 I/O Port 1 /sbus@78,0 scard 14.0.1 SBUS 0 SLOT 1 SB 14.0.1 I/O Port 2 /sbus@79,0 scard 14.1.0 SBUS 1 SLOT 0 SB 14.1.0 I/O Port 3 /sbus@79,0 scard 14.1.1 SBUS 1 SLOT 1 SB 14.1.1 System Board 15 sysbd 15 SB15 SB15 I/O Port 0 /sbus@7c,0 scard 15.0.0 SBUS 0 SLOT 0 SB 15.0.0 I/O Port 1 /sbus@7c,0 scard 15.0.1 SBUS 0 SLOT 1 SB 15.0.1 I/O Port 2 /sbus@7d,0 scard 15.1.0 SBUS 1 SLOT 0 SB 15.1.0 I/O Port 3 /sbus@7d,0 scard 15.1.1 SBUS 1 SLOT 1 SB 15.1.1 Processors Component Solaris Hostview POST upaid System Board 0 SB0 sysbd 0 Proc Module 0 /SUNW,UltraSPARC@0,0 00 proc 0.0 0x0 Proc Module 1 /SUNW,UltraSPARC@1,0 01 proc 0.1 0x1 Proc Module 2 /SUNW,UltraSPARC@2,0 02 proc 0.2 0x2 Proc Module 3 /SUNW,UltraSPARC@3,0 03 proc 0.3 0x3 System Board 1 SB1 sysbd 1 Proc Module 0 /SUNW,UltraSPARC@4,0 04 proc 1.0 0x8 Proc Module 1 /SUNW,UltraSPARC@5,0 05 proc 1.1 0x9 Proc Module 2 /SUNW,UltraSPARC@6,0 06 proc 1.2 0xa Proc Module 3 /SUNW,UltraSPARC@7,0 07 proc 1.3 0xb System Board 2 SB2 sysbd 2 Proc Module 0 /SUNW,UltraSPARC@8,0 08 proc 2.0 0x10 Proc Module 1 /SUNW,UltraSPARC@9,0 09 proc 2.1 0x11 Proc Module 2 /SUNW,UltraSPARC@a,0 10 proc 2.2 0x12 Proc Module 3 /SUNW,UltraSPARC@b,0 11 proc 2.3 0x13 System Board 3 SB3 sysbd 3 Proc Module 0 /SUNW,UltraSPARC@c,0 12 proc 3.0 0x18 Proc Module 1 /SUNW,UltraSPARC@d,0 13 proc 3.1 0x19 Proc Module 2 /SUNW,UltraSPARC@e,0 14 proc 3.2 0x1a Proc Module 3 /SUNW,UltraSPARC@f,0 15 proc 3.3 0x1b System Board 4 SB4 sysbd 4 Proc Module 0 /SUNW,UltraSPARC@10,0 16 proc 4.0 0x20 Proc Module 1 /SUNW,UltraSPARC@11,0 17 proc 4.1 0x21 Proc Module 2 /SUNW,UltraSPARC@12,0 18 proc 4.2 0x22 Proc Module 3 /SUNW,UltraSPARC@13,0 19 proc 4.3 0x23 System Board 5 SB5 sysbd 5 Proc Module 0 /SUNW,UltraSPARC@14,0 20 proc 5.0 0x28 Proc Module 1 /SUNW,UltraSPARC@15,0 21 proc 5.1 0x29 Proc Module 2 /SUNW,UltraSPARC@16,0 22 proc 5.2 0x2a Proc Module 3 /SUNW,UltraSPARC@17,0 23 proc 5.3 0x2b System Board 6 SB6 sysbd 6 Proc Module 0 /SUNW,UltraSPARC@18,0 24 proc 6.0 0x30 Proc Module 1 /SUNW,UltraSPARC@19,0 25 proc 6.1 0x31 Proc Module 2 /SUNW,UltraSPARC@1a,0 26 proc 6.2 0x32 Proc Module 3 /SUNW,UltraSPARC@1b,0 27 proc 6.3 0x33 System Board 7 SB7 sysbd 7 Proc Module 0 /SUNW,UltraSPARC@1c,0 28 proc 7.0 0x38 Proc Module 1 /SUNW,UltraSPARC@1d,0 29 proc 7.1 0x39 Proc Module 2 /SUNW,UltraSPARC@1e,0 30 proc 7.2 0x3a Proc Module 3 /SUNW,UltraSPARC@1f,0 31 proc 7.3 0x3b System Board 8 SB8 sysbd 8 Proc Module 0 /SUNW,UltraSPARC@20,0 32 proc 8.0 0x40 Proc Module 1 /SUNW,UltraSPARC@21,0 33 proc 8.1 0x41 Proc Module 2 /SUNW,UltraSPARC@22,0 34 proc 8.2 0x42 Proc Module 3 /SUNW,UltraSPARC@23,0 35 proc 8.3 0x43 System Board 9 SB9 sysbd 9 Proc Module 0 /SUNW,UltraSPARC@24,0 36 proc 9.0 0x48 Proc Module 1 /SUNW,UltraSPARC@25,0 37 proc 9.1 0x49 Proc Module 2 /SUNW,UltraSPARC@26,0 38 proc 9.2 0x4a Proc Module 3 /SUNW,UltraSPARC@27,0 39 proc 9.3 0x4b System Board 10 SB10 sysbd 10 Proc Module 0 /SUNW,UltraSPARC@28,0 40 proc 10.0 0x50 Proc Module 1 /SUNW,UltraSPARC@29,0 41 proc 10.1 0x51 Proc Module 2 /SUNW,UltraSPARC@2a,0 42 proc 10.2 0x52 Proc Module 3 /SUNW,UltraSPARC@2b,0 43 proc 10.3 0x53 System Board 11 SB11 sysbd 11 Proc Module 0 /SUNW,UltraSPARC@2c,0 44 proc 11.0 0x58 Proc Module 1 /SUNW,UltraSPARC@2d,0 45 proc 11.1 0x59 Proc Module 2 /SUNW,UltraSPARC@2e,0 46 proc 11.2 0x5a Proc Module 3 /SUNW,UltraSPARC@2f,0 47 proc 11.3 0x5b System Board 12 SB12 sysbd 12 Proc Module 0 /SUNW,UltraSPARC@30,0 48 proc 12.0 0x60 Proc Module 1 /SUNW,UltraSPARC@31,0 49 proc 12.1 0x61 Proc Module 2 /SUNW,UltraSPARC@32,0 50 proc 12.2 0x62 Proc Module 3 /SUNW,UltraSPARC@33,0 51 proc 12.3 0x63 System Board 13 SB13 sysbd 13 Proc Module 0 /SUNW,UltraSPARC@34,0 52 proc 13.0 0x68 Proc Module 1 /SUNW,UltraSPARC@35,0 53 proc 13.1 0x69 Proc Module 2 /SUNW,UltraSPARC@36,0 54 proc 13.2 0x6a Proc Module 3 /SUNW,UltraSPARC@37,0 55 proc 13.3 0x6b System Board 14 SB14 sysbd 14 Proc Module 0 /SUNW,UltraSPARC@38,0 56 proc 14.0 0x70 Proc Module 1 /SUNW,UltraSPARC@39,0 57 proc 14.1 0x71 Proc Module 2 /SUNW,UltraSPARC@3a,0 58 proc 14.2 0x72 Proc Module 3 /SUNW,UltraSPARC@3b,0 59 proc 14.3 0x73 System Board 15 SB15 sysbd 15 Proc Module 0 /SUNW,UltraSPARC@3c,0 60 proc 15.0 0x78 Proc Module 1 /SUNW,UltraSPARC@3d,0 61 proc 15.1 0x79 Proc Module 2 /SUNW,UltraSPARC@3e,0 62 proc 15.2 0x7a Proc Module 3 /SUNW,UltraSPARC@3f,0 63 proc 15.3 0x7b Product Sun Enterprise 10000 Server Internal Comments For Internal Use Only http://systems-tsc/twiki/bin/view/Products/ProdTechTipsStarfireHardwareComponentNumbering#pci Will archive: Document ID: 81330, 15050, and 74984 after release 10k, E10k, starfire, sbus, pci, I/O, io, device, path, slot, numbers Previously Published As 87631 Change History Updated by the ESG Knowledge Content Team 4/2010 Product_uuid 29ddef46-0a18-11d6-92de-ae47474f0f6c|Sun Enterprise 10000 Server Attachments This solution has no attachment |
||||||||||||
|