Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1005365.1
Update Date:2011-05-23
Keywords:

Solution Type  Technical Instruction Sure

Solution  1005365.1 :   Sun StorageTek[TM] 2530 (SAS) Firmware Matrix  


Related Items
  • Sun Storage 2530 Array
  •  
  • Sun Storage Common Array Manager (CAM)
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 2xxx Arrays
  •  

PreviouslyPublishedAs
207479
This article documents Sun StorageTek 2530 (SAS) Array's components firmware baseline bundled in each corresponding CAM release and patched versions.

In this Document
  Goal
  Solution


Applies to:

Sun Storage Common Array Manager (CAM) - Version: 5.1 and later   [Release: 5.0 and later ]
Sun Storage 2530 Array - Version: Not Applicable and later    [Release: N/A and later]
All Platforms

Goal


To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community, Storage Disk 6000 and 2000 Series RAID Arrays Community.


This article documents Sun StorageTek 2530 (SAS) Array's components firmware baseline bundled in each corresponding CAM release and patched versions.

This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware and management software compatibility.

For instructions to download CAM, please refer to <Document 1296274.1> How to Download Common Array Manager (CAM) Software and Patches.

Solution

Baseline / CAM Release 2500 Series Release Sun StorageTek 2530 (SAS) Firmware
Patch Controller Expansion
Firmware NVSRAM NVSRAM-S ST2501
1.x no support
2.x
5.0.x.x
5.1.0.x
5.1.2.2 R1.0a 124157-03 no support
5.1.3.2 R1.1 124157-03 06.17.52.10 N133X-617843-003 N133X-617843-904 0166
5.1.3.2 R1.2 127486-01b
127487-02 
127488-01 
06.70.00.11 N133X-670843-001 N133X-670843-901 0183
6.0.0.10     06.17.52.10 N133X-617843-003 N133X-617843-904 0166
6.0.0.10 R1.2 128269-01c
128270-01 
128271-01 
06.70.00.11 N133X-670843-001 N133X-670843-901 0183
6.0.0.10   128269-02
128270-02
128271-02
06.70.00.11 N133X-670843-001 N133X-670843-901 0183
6.0.0.10   128269-03
128270-03
128271-03
06.70.00.11 N133X-670843-001 N133X-670843-901 0183
6.0.0.10   128269-04
128270-04
128271-04
06.70.00.14 N133X-670843-001 N133X-670843-901 0183
6.0.0.10   128269-05
128270-05
128271-05
06.70.00.14 N133X-670843-001 N133X-670843-901 0183
6.0.1.11 R1.3   06.70.42.10 N133X-670843-001 N133X-670843-901 0186
6.0.1.11   137294-01
137295-01
137296-01
06.70.54.10d  
6.1.0.16     06.70.54.10 N133X-670843-001 N133X-670843-901 0186
6.1.0.16   137934-01e
137935-01 
137936-01 
06.70.54.11  
6.1.0.16   137934-02f
137935-02 
137936-02 
06.70.54.11  
6.1.1.10     06.70.54.10 N133X-670843-001 N133X-670843-901 0186
6.1.1.10   139034-01g
139035-01 
139036-01 
06.70.54.11  
6.1.2.8     06.70.54.11 N133X-670843-001 N133X-670843-901 0186
6.2.0.13 R1.4   06.70.54.11 N133X-670843-001 N133X-670843-901 0195
07.35.10.10h N133X-735843-002h N133X-735843-902h
6.2.0.14   140064-01i
140066-01 
140065-01 
(Required by 14006[012]-01, up-rev'd CAM to 6.2.0.14.)
6.2.0.14   140060-01i
140061-01 
140062-01 
 
(2530_exmoor.properties updated)  
6.2.0.14   controlled 07.35.10.13j  
6.3.0     (CAM 6.3 was never released.)
6.4.0.10     06.70.54.11 N133X-670843-001 N133X-670843-901 0195
07.35.10.10 N133X-735843-002 N133X-735843-902
6.4.0.10   controlled 07.35.10.13j  
6.4.1.5     06.70.54.11 N133X-670843-001 N133X-670843-901 0195
07.35.44.10k N133X-735843-002 N133X-735843-902
6.5.0.10     06.70.54.11 N133X-670843-001 N133X-670843-901 0195
07.35.44.10 N133X-735843-002 N133X-735843-902
6.5.0.x   142798-01 
142799-01 
142800-01 
  0196
07.35.50.10  
6.5.0.13   142798-02 
142799-02 
142800-02 
  0196
07.35.50.10  
6.6.0.11l     06.70.54.11 N133X-670843-001 N133X-670843-901 0196
07.35.50.10 N133X-735843-002 N133X-735843-902
6.6.0.12l   141474-01l
141475-01 
141476-01 
(CR6935284 CAM BUI host types do not match array hostregion.)
6.6.0.12   143759-01
143760-01
143761-01
   
07.35.55.10  
6.7.0.12     06.70.54.11 N133X-670843-001 N133X-670843-901 0196
07.35.55.10 N133X-735843-002 N133X-735843-902
6.7.0.13 (Windows Only)   144861-01 (CAM core patch for Windows only. Fixes CR6968739 J4410 reporting incorrect chassis serial number; and CR6972298 Win2008 undefined constant.)
6.7.0.x   145965-02
145966-02
145967-02
   
07.35.55.11 (Seagate drives firmware fixes for 6000/2500/J4000; 6000/2500 controller firmware fixes. Includes all previous fixes in 14596[567]-*.)
Baseline / CAM Release 2500 Series Release Patch Firmware NVSRAM NVSRAM-S ST2501
Controller Expansion
Sun StorageTek 2530 (SAS) Firmware
NOTE: Firmware shown as "controlled" are not publicly available and is only provided on a case-by-case basis as deemed necessary by support services.

a Release 1.0 was for 2540 GA, although firmware of 2530 was included, 2530 itself was not yet released and therefore, is not supported with R1.0.
b Patches 12748[678]-xx are for CAM 5.1.x only and was released independent of CAM 6.0. Take note that CAM 6.0 has LOWER rev of firmware, and these patches cannot be applied directly on CAM 6.0 due to packaging differences (dir structure changed).
c Patches 1282{69|70|71}-01 are for CAM 6.0 only and contains the same firmware as that of CAM 5.1.x patches 12748[678]-xx.
d Patches 13729[456]-01, new controller firmware for 48 drives support.
e Patches 13793[456]-01, controller network issue bug fix, for CAM 6.1.0.
f Patches 13793[456]-02, controller network issue bug fix to include 6140, firmware for 2500 same as -01.
g Patches 13903[456]-01, controller network issue bug fix for 2500 and 6140 for CAM 6.1.1.
h CAM 6.2.0 supports and bundles 7.35 firmware for 2500 series arrays, however upgrade utility is a separate download. This firmware upgrade can be done by customer. [Upgrade Guide / Utility ]
i Patches 14006[012]-01, 2530_exmoor.properties fix for CR6762669 Unable to upgrade NVSRAM firmware on a simplex 2530 array; requires CAM core patch 14006[456]-01.
j 7.35.10.13 contains the fix for SA256288 but was not bundled in CAM 6.4.0.
k 7.35.44.10 fixes SA256288 and supersedes 7.35.10.13.
l CAM 6.6.0.11 host types do not match array's host region (CR6935284), affecting 2500, 6140, 6180, 6540, 6580/6780. This may result in either new mappings selecting the wrong host region, or user confused by the display and change existing mappings which was correct, to become wrong. CAM 6.6.0.12 through patch 14147[456]-01 was specifically released to resolve this bug.

Internal website for CAM supported array firmware matrix.
http://tsc-storage.us/products/CAM/matrix.html
This site is typically updated first before being edited for public consumption.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback