Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1005106.1 : Sun StorEdge[TM] A1000 array: Battery Replacement
PreviouslyPublishedAs 207173 Description This procedure describes how to check the age of a battery in a Sun StorEdge[TM] A1000 Array, and how to replace it. Steps to Follow 1. Run the following Sun StorEdge RAID Manager 6(RM6) CLI command: Determine the device name: #/usr/lib/osa/bin/lad c1t0d0 1T93803809 LUNS: 0 1 Determine the battery age, use the device name listed in lad command: /usr/lib/osa/bin/raidutil -c <device> -B For example: #/usr/lib/osa/bin/raidutil -c c1t0d0 -B LUNs found on c1t0d0. LUN 0 RAID 0 10 MB LUN 1 RAID 5 1000 MB Battery age is between 720 days and 810 days. raidutil succeeded! battery age between 630 and 720 days - near expiration battery age greater than 720 days - expired Battery should be replaced for all the above cases. NOTE: A1000 battery is not hotswappable. The RM6 GUI can be started by issuing the command #/usr/lib/osa/bin/rm6 & If you want disable the Write Caching option, follow the steps below by using the RM6's GUI or command line commands. But in case, where the battery has already expired, cache function for write operations has been switched off automatically. 2. Using RM6 GUI, open the Maintenance and Tuning application. 3. Select the RAID module for the Sun StorEdge A1000 array. 4. Click the Cache Parameters button, or select Option -> Cache 5. Disable the Write Caching option. OR by using the RM6 command line commands: #/usr/lib/osa/bin/lad c1t0d0 1T93803809 LUNS: 0 1 Write cache disabling: #/usr/lib/osa/bin/raidutil -c <device> -w off <lun numbers> #/usr/lib/osa/bin/raidutil -c c1t0d0 -w off 0,1 LUNs found on c5t5d0. LUN 0 RAID 5 8100 MB LUN 1 RAID 5 8108 MB 6. Stop the host machine that is connected to the Sun StorEdge A1000 array. # init 0 7. Before turning off the StorEdge A1000 array, wait approximately two minutes 8. Boot the host machine, without the -r option. 9. After the battery replacement, run the following RM6 command to reset For example: #/usr/lib/osa/bin/raidutil -c c1t0d0 -R LUNs found on c1t0d0. LUN 0 RAID 0 10 MB LUN 1 RAID 5 1000 MB raidutil succeeded! 10. Check the new battery age: For example: #/usr/lib/osa/bin/raidutil -c c1t0d0 -B LUNs found on c1t0d0. LUN 0 RAID 0 10 MB LUN 1 RAID 5 1000 MB Battery age is between 0 days and 90 days. raidutil succeeded! 11. Re-enable the Write Caching option by using the RM6 GUI or by using Write cache enabling: #/usr/lib/osa/bin/raidutil -c c1t0d0 -w on 0,1 LUNs found on c5t5d0. LUN 0 RAID 5 8100 MB LUN 1 RAID 5 8108 MB 12. After 12 hours, check to see if the battery is working, for example running Product Sun StorEdge A1000 Array RAID Manager 6.22.1 battery, A1000, detecting battery age, replacing battery, how to replace Previously Published As 73379 Change History Date: 2006-01-06 User Name: 95826 Action: Approved Comment: According to previous comments, many people think that this document is not useful as its subject has already been covered by Relases Notes, FIN, ... But this document gathers a decent amount of hits, externally and internally : http://krep.emea.sun.com/stats/dochistory.cgi?docid=73379 As it is used, I let it stay on Sunsolve. Date: 2009-12-01 User: DeCotis Comment: Document is current, as is. Attachments This solution has no attachment |
||||||||||||
|