Solution Type Technical Instruction Sure Solution 1005088.1 : How to cleanly remove a Sun StorEdge[TM] A5x00 array from a system without downtime
PreviouslyPublishedAs 207150 Description The procedure for removing an A5x00 array from a system is actually very simple, and can be performed without interrupting system operation. However, it's not clearly explained in the product documentation. Steps to Follow How to cleanly remove a Sun StorEdge[TM] A5x00 array from a system without downtime 1. Stop all I/O to the array: 2. Remove the device paths for the disk array: 3. Power off the array. 4. Go back to the terminal window where the luxadm command is waiting (from step 2) and press return. 5. Disconnect the cables from the array to the host. 6. Verify you know longer see the array: Product Sun StorageTek A5200 Array Sun StorageTek A5100 Array Sun StorageTek A5000 Array photon, a5100, a5200, a5000, detach, move, migrate Previously Published As 81145 Change History Date: 2005-05-05 User Name: 25440 Action: Approved Comment: Publishing. Version: 3 Date: 2005-05-05 User Name: 25440 Action: Accept Comment: Version: 0 Date: 2005-05-05 Attachments This solution has no attachment |
||||||||||||
|