Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1004928.1
Update Date:2010-09-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1004928.1 :   Sun Fire[TM] V240: How to Identify Fans  


Related Items
  • Sun Fire V240 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
206913


Description
How to identify and locate fans on a V240.


Steps to Follow
On a V240 you will see the fans referred to as:
  F0.RS <- system fan 0
F1.RS <- system fan 1
F2.RS <- system fan 2
MB.P0.F0.RS or MB/P0/F0 <- motherboard fan 0 position 0
MB.P0.F1.RS or MB/P0/F1 <- motherboard fan 1 position 1
  MB.P1.F0.RS or MB/P1/F0 <- motherboard fan 0 position 0
MB.P1.F1.RS or MB/P1/F1 <- motherboard fan 1 position 1
    ex:  MB.P0.F0.RS would be cpu0's fan0 on the mb and not
one of the system fans

System Fans:

Looking down on the V240 with the cover removed, and the front to the
left, System fan 0 is on top, system fan 1 is in the middle and system
fan 2 is on the bottom.

See:

https://support.oracle.com/handbook_private/Systems/SunFireV240/component.top.html

CPU fans:

Looking down on the system board with the external connections at the
bottom:

MB.P0.F0.RS is the left fan of processor 0 (bottom processor) and
MB.P0.F1.RS is the right fan of processor 0 (bottom processor)
MB.P1.F0.RS is the left fan of processor 1 (top processor) and
MB.P1.F1.RS is the right fan of processor 1 (top processor).

See:

https://support.oracle.com/handbook_private/Devices/System_Board/SYSBD_SunFireV2x0_CPU.html



Product
Sun Fire V240 Server

Internal Comments
Audited/updated 12/02/09 - [email protected], Entry Level SPARC Content Team Member




V240, fan, F0.RS, F1.RS, MB.P0.F0.RS, MB.P0.F1.RS, MB.P1.F0.RS, MB.P1.F1.RS
Previously Published As
76689

Change History
Corrected the motherboard fan positions per [email protected] request on 6/4/09

should be:

MB.P0.F0.RS or MB/P0/F0 <- motherboard fan 0 position 0
MB.P0.F1.RS or MB/P0/F1 <- motherboard fan 1 position 1

MB.P1.F0.RS or MB/P1/F0 <- motherboard fan 0 position 0
MB.P1.F1.RS or MB/P1/F1 <- motherboard fan 1 position 1

Date: 2005-04-20
User Name: 97961
Action: Accept
Comment:
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.