Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1004630.1
Update Date:2010-08-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1004630.1 :   What is the Minimum Disk Drive Configuration for a Sun StorEdge[TM] A5X00?  


Related Items
  • Sun Storage A5000 Array
  •  
  • Sun Storage A5200 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
206419


Description
Below is the minimum disk configuration supported on the A5X00 disk
arrays


Steps to Follow
What is the Minimum Disk Drive Configuration for a Sun StorEdge[TM] A5X00?

14-slot array

In the minimum disk drive configuration for the 14-slot disk array,
disk drives are shipped in rear backplane slots 0, 3, and 6 as well
as front backplane slots 3 and 6.

22-slot array

In the minimum disk drive configuration for the 22-slot disk array,
disk drives are shipped in rear backplane slots 0, 3, 6, and 10 as well
as front backplane slot 0, 5, and 10.

How to Verify Minimum Config when remote from system:

1. luxadm probe <-This command will give you the enclosure name

 example# luxadm probe
Found Enclosure:
SENA               Name:Photon   Node WWN:50800200000685f0   Logical Path:/dev/es/ses

2. luxadm display enclosure_name

 example## luxadm display Photon
                                    SENA
DISK STATUS
SLOT   FRONT DISKS       (Node WWN)          REAR DISKS        (Node WWN)
0      On(O.K.)          200000203722c7be    On(O.K.)          200000203722d2e5
1      Not Installed                         Not Installed
2      Not Installed                         Not Installed
3      Not Installed                         On (O.K.)         200000203722ce33
4      Not Installed                         Not Installed
5      On  (O.K.)        200000203722c7be    Not Installed
6      Not Installed                         On (O.K.)         200000203722cd73
7      Not Installed                         Not Installed
8      Not Installed                         Not Installed
9      Not Installed                         Not Installed
10     On  (O.K.)        200000203722cfaa    On  (O.K.)200000203722cce7

NOTE:
From the "luxadm display" command you can see the it has 22 slots and contains the minimum config.

======================================================
DO NOT MOVE DISK DRIVES FROM THE MINIMUM CONFIGURATION
======================================================

For additional information, please see the Sun StorEdge A5000 Installation
and Service Manual, P/N 802-7573 Chapter 1.



Product
Sun StorageTek A5200 Array
Sun StorageTek A5100 Array
Sun StorageTek A5000 Array

minimum disk configuration, A5x00, photon, A5200, A5100, A5000
Previously Published As
20778

Change History
Date: 2005-02-11
User Name: 7058
Action: Approved
Comment: Activated STM to offset preformatted text and create underlines for the sections.
Review date OK.
OK to republish.
Version: 3
Date: 2005-02-11

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback