Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1004453.1 : Sun Enterprise[TM] 10000: How to run hpost on system board with no I/O configured
PreviouslyPublishedAs 206148 Description How to run hpost on system board with no I/O configured. Steps to Follow When running hpost on a standalone system board which doesn't have any Sbus cards, hpost will fail as follows : phase iom_probe: I/O module type probe... To allow the system board to run without any I/O, simply add the following entry to the .postrc file for the domain. no_scards_ok This file is located in /var/opt/SUNWssp/etc/<platform>/<domain>/.postrc. Similar issues with system boards without memory can be avoided by adding the entry to the .postrc file: no_memory_ok Product Sun Enterprise 10000 Server Internal Comments For internal Sun use only. Document still valid E10000, hpost, ecode 76, .postrc, unable, configure bootable system, post, failure Previously Published As 19897 Change History Date: 2009-11-18 User Name: Volkmar Grote 117021 Action: Reviewed for Content Team Comment: no change Version: Date: 2004-09-20 User Name: 18392 Action: Approved Comment: Turned on STM formatting for readability Version: 3 Date: 2004-09-20 User Name: 18392 Action: Accept Comment: Version: 0 Date: 2004-09-20 User Name: 119729 Action: Approved Comment: Looks good. Version: 0 Date: 2004-09-20 User Name: 119729 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|