Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1004261.1 : Sun Fire[TM] X4600 M2 Server: Some 8xDIMM CPU Books have their DIMMs installed in incorrect location
PreviouslyPublishedAs 205889 Description Disclaimer: Opening and examining cards and moving DIMMs will not void warranty when conforming with the instructions of this technical instruction. Instead of correctly populating DIMMs in pairs starting from white DIMM slots furthermost from the CPU (DIMM 6 and 7), DIMM pairs were incorrectly populated in manufacturing starting from black DIMM slots closest to the CPU (DIMM 0 and 1). Incorrectly populated DIMMs have not been verified to work stably by Engineering and should be avoided. Steps to Follow Affected part number: All x4600(M2) 8xDIMM CPU Book Configurations. Serial Number range: Contact Sun support for more information. Symptom: Systems may experience intermittent power downs or panics when DIMMs are installed incorrectly. Corrective Action: Ensure all CPU Books have DIMMs populated in pairs starting from white DIMM pair furthermost from CPU. Reference docs: Sun Fire X4600 and Sun Fire X4600 M2 Servers Service Manual (819-4342) - Appendix F
Disclosure:
Product Sun Fire X4600 M2 Server Internal Comments Audited/updated 20/11/09 - [email protected], x64 Content Team Member x4600, 8 dimm, reboot, intermitant, dimm, configuration Previously Published As 91304 Change History Date: 2007-12-03 User Name: 97961 Action: Approved Comment: - Added disclaimer according to words in the comments area Version: 5 Date: 2007-12-03 Attachments This solution has no attachment |
||||||||||||
|