Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1004207.1 : C4 - "Broken" Pulley in Robotics Module
PreviouslyPublishedAs 205823
Applies to:Sun Storage C4 Tape LibraryAll Platforms Checked for relevance on 5-Jan-2011. GoalThe C4 tape library has been occasionally misdiagnosed with a broken drive belt pulley. In fact the pulley is designed with a cut out on it that is mistaken for a defect.SolutionSteps to FollowThe C4 tape library has a robot mechanism for handling the tape cartridges. One of the drive pulleys in that mechanism is designed with a notch on it. Some people have mistakenly thought that was a broken pulley, when in fact it is manufactured that way. The library is not defective and should not be replaced. Verify the operation of the library using local diagnostics if in doubt. Product Sun StorageTek C4 Tape Library Internal Comments Don't be swapping the robotics out for this notched pulley. This document is also available on the legacy STK support application Primus as ID: STKKB79427. c4, pulley, library, broken, belt Previously Published As 87969 Attachments This solution has no attachment |
||||||||||||
|