Goal
This document describes the three replacement methods and
provides information on which FRUs can be replaced using which
method(s). This document should be used to decide which
method is best to utilize given the system configuration and the
FRU which requires service.
Solution
Description
Field Replaceable Units (FRUs) can be replaced on Sun SPARC Enterprise[TM] Mx000 systems using one of three possible replacement methods:
Cold Replacement
-
Hot Replacement
-
Active Replacement
This document is
Step 5
of Document 1002526.1 Sun SPARC Enterprise
Mx000: Field Replaceable
Unit (FRU) Service Action Plan Reference.
Regarding Hard Disk Drive (HDD) Replacement Methods
If the HDD is the boot device, it will have to
be replaced using cold replacement procedures. However, active
replacement can be used if the boot disk can be isolated from the
Oracle Solaris OS by disk mirroring software and other software.
Steps to Follow
Cold Replacement Method requires all domains and the entire platform be shut down and powered off in order to replace the FRU. Every FRU in Mx000 platforms can be Cold Replaced, but some must be replaced using this method.
Cold Replacement Method
The components which must be Cold Replaced
on M3000 are:
MBU_A MBU_A_2 DIMM PCIe HDDBP
PSU DVDU FAN_A FANBP_B OPNL
The components which must be Cold Replaced on M4000/M5000 are:
MBU_A MBU_B CMU_A MEMB DIMM
DDC_A DDC_B XSCFU IOU DDCR
FANBP_A FANBP_B FANBP_C BPU_A BPU_B
HDDBP TAPEBP DVD DVDBP_A DVDBP_B
OPNL
The components
which must be Cold Replaced on M8000/M9000 are:
XBU_B CLKU_B OPNL SNSU ACS_A
ACS_B ACS_C ACS_D ACSTPH_A ACSTPH_B
ACSTPH-C ACSTPH-D BP_A BP_B PSUBP_A
PSUBP_B FANBP_A FANBP_B FANBP_C MEDBP
SWBP RDPF
The following
steps are simply a reference to make one aware of what is involved in
the Cold Replacement Method process, but the Service Manual is the
authoritative resource for the actual process to be followed.
Shut down
all applications (if running) on all domains on platform.
Shut down
all domains.
Power off
the platform.
Unplug
the power cords (Make sure to be at the same potential as the
system).
Initiate
FRU replacement.
Power on
the platform and verify FRU replacement is successful.
Bring
domains and applications back online.
Hot Replacement Method
Hot Replacement Method requires that the domain(s) containing the
faulty FRU be shut down in order to replace it. The remainder
of the platform can stay in operation during the service period. Fans
and PSUs are not part of domains and can therefore be replaced while
all domains are running. Special rules apply for these FRUs to
guarantee redundancy during the replacement operation, they are
described later in this document.
The components which can be Hot Replaced on M3000 are:
FAN_A HDD PSU
The components which can be Hot Replaced on M4000/M5000 are:
FAN_A FAN_B PSU
The components which can be Hot Replaced on M8000/M9000 are:
CMU CPUM_A CPUM_B DIMM IOU
HDD PCICS IOUA PCIB-EX XSCFU_B
XSCFU_C PSU FAN_A FAN_B DDC_A
DVDU TAPEU
The following steps are simply a reference to make one aware of what
is involved in the Hot Replacement Method process, but the Service
Manual is the authoritative resource for the actual process to be
followed.
Shut down applications (if running) on domains that contain the FRU.
Shut down domains that contain the FRU.
Initiate FRU replacement.
Verify FRU replacement is successful.
Bring affected domains and applications back online.
Active Replacement Method
Active Replacement Method can only be used on redundantly configured
FRUs that can be Dynamically Reconfigured (DR) into or out of a
domain. No interruption to domain or platform operations will
occur when utilizing this method. Fans and PSUs are not part of
domains and can therefore be replaced while all domains are running
NOTE: Active Replacement was not
available until
XCP 1050.
The components which can be Active Replaced on M3000 are:
HDD PSU FAN_A
The components which can be Active Replaced on M4000/M5000 are:
PCICS HDD TAPE
The components which can be Active Replaced on M8000/M9000 are:
CMU CPUM_A CPUM_B DIMM IOU
HDD PCICS IOUA PCIB-EX XSCFU_B
XSCFU_C DVDU TAPEU PSU FAN_A
FAN_B DDC_A
The following steps are simply a reference to make one aware of what
is involved in the Active Replacement Method process, but the Service
Manual is the authoritative resource for the actual process to be
followed.
Verify the FRU is redundantly configured in all
domains in which this FRU is configured.
Verify the FRU and all dependent hardware on the FRU (I/O
adapters, etc) are inactive.
Verify that resources are switched to alternate paths (I/O,
network, etc) if necessary. This may include breaking disk
mirrors or utilizing multi-pathing software to perform the actions.
Initiate FRU replacement utilizing Dynamic Reconfiguration.
Verify FRU replacement is successful.
Verify that any inactivated paths are re-enabled for all
affected domains. This may include syncing disk mirrors or
utilizing multi-pathing software to perform the actions.
Verify that the affected domains and applications are all
still online without issues.
FRU List Tables
Sun SPARC Enterprise M3000
|
FRU |
Description |
Cold Replacement |
Hot Replacement |
Active Replacement |
MBU_A |
Motherboard Unit (M3000) |
Yes |
No |
No |
Dimm |
Main Memory DIMM |
Yes |
No |
No |
PCIe |
PCIe Card |
Yes |
No |
No |
HDD |
Hard Disk Drive |
Yes |
Yes |
Yes if Mirrored |
HCCBP |
Hard disk drive backplane |
Yes |
No |
No |
DVDU |
CD-RW/DVD-RW drive unit |
Yes |
No |
No |
PSU |
Power Supply Unit |
Yes |
Yes |
Yes |
FAN_A |
Fan |
Yes |
Yes |
Yes |
FANBP_B |
Fan backplane |
Yes |
No |
No |
OPNL |
Operator Panel |
Yes |
No |
No |
Sun SPARC Enterprise M4000/M5000
|
FRU
|
Description
|
Cold Replacement
|
Hot Replacement
|
Active Replacement
|
MBU_A
|
Motherboard Unit (M4000)
|
Yes
|
No
|
No
|
MBU_B
|
Motherboard Unit (M5000)
|
Yes
|
No
|
No
|
DDC_A
|
DC-DC Converter (Motherboard and IO Unit)
|
Yes
|
No
|
No
|
DDC_B
|
DC-DC Converter with metal heatsink (Motherboard and IO Unit)
|
Yes
|
No
|
No
|
CMU_A
|
CPU Module Unit
|
Yes
|
No
|
No
|
MEMB
|
Memory Board
|
Yes
|
No
|
No
|
DIMM
|
Main Memory DIMM (1, 2, or 4GB)
|
Yes
|
No
|
No
|
XSCFU
|
eXtended System Control Facility Unit
|
Yes
|
No
|
No
|
IOU
|
I/O Unit
|
Yes
|
No
|
No
|
DDCR
|
I/O DC Riser
|
Yes
|
No
|
No
|
PCIC
|
PCI Cassette (including PCI card)
|
Yes
|
No
|
Yes
|
FAN_A
|
172mm Fans
|
Yes
|
Yes, One unit at a time to support redundancy
|
No
|
FAN_B
|
60mm Fan (M4000)
|
Yes
|
Yes, One unit at a time to support redundancy
|
No
|
FANBP_A
|
172mm Fan Backplane (M4000)
|
Yes
|
No
|
No
|
FANBP_B
|
60mm Fan Backplane (M4000)
|
Yes
|
No
|
No
|
FANBP_C
|
172mm Fan Backplane (M5000)
|
Yes
|
No
|
No
|
PSU
|
Power Supply Unit
|
Yes
|
Yes, One unit at a time to support redundancy
|
No
|
BPU_A
|
I/O Backplane / Power Backplane (M4000)
|
Yes
|
No
|
No
|
BPU_B
|
Bus Bar / I/O Backplane / Power Backplane (M5000)
|
Yes
|
No
|
No
|
HDD
|
73GB Hard Disk Drive
|
Yes
|
Yes
|
Yes, if mirrored
|
HDDBP
|
Hard Disk Drive backplane
|
Yes
|
No
|
No
|
TAPE
|
DAT Tape Drive (Optional)
|
Yes
|
No
|
Yes
|
TAPEBP
|
DAT Tape Drive Backplane
|
Yes
|
No
|
No
|
DVD
|
DVD Drive
|
Yes
|
No
|
No
|
DVDBP_A
|
DVD Drive Backplane (M4000)
|
Yes
|
No
|
No
|
DVDBP_B
|
DVD Drive Backplane (M5000)
|
Yes
|
No
|
No
|
OPNL
|
Operator Panel
|
Yes
|
No
|
No
|
The information in the table above comes from the Sun SPARC
Enterprise M4000/M5000 Servers Service Manual, Appendix C.
Sun SPARC Enterprise M8000/M9000 FRU Replacement Options
|
FRU
|
Description
|
Cold Replacement
|
Hot Replacement
|
Active Replacement
|
CMU
|
CPU Memory Board Unit
|
Yes
|
Yes
|
Yes
|
CPUM_A
|
CPU Module
|
Yes
|
Yes
|
Yes
|
CPUM_B
|
CPU Module
|
Yes
|
Yes
|
Yes
|
DIMM
|
Main Memory DIMM
|
Yes
|
Yes
|
Yes
|
IOU
|
I/O Unit
|
Yes
|
Yes
|
Yes, when redundantly configured. (Uses DR)
|
HDD
|
Hard Disk Drive
|
Yes
|
Yes
|
Yes, if mirrored
|
PCICS
|
PCI Cassette (including PCI board)
|
Yes
|
Yes
|
Yes, when multi path is configured.
|
IOUA
|
On board Device Card
|
Yes
|
Yes
|
Yes, if boot disks are mirrorred and multipathed
|
PCIB-EX
|
I/O Box Down Link Card
|
Yes
|
Yes
|
Yes
|
XBU_B
|
Crossbar Units
|
Yes
|
No
|
No
|
CLKU_B
|
Clock Control Units
|
Yes
|
No
|
No
|
XSCFU_B
|
XSCF Units (Base Cabinet)
|
Yes
|
Yes
|
Yss
|
XSCFU_C
|
XSCF Unit (M9000 Expansion Cabinet)
|
Yes
|
Yes
|
Yes
|
DVDU
|
DVD Drive Unit
|
Yes
|
Yes
|
Yes
|
TAPEU
|
Tape Drive Unit
|
Yes
|
Yes
|
Yes
|
OPNL
|
Operator Panel
|
Yes
|
No
|
No
|
SNSU
|
Sensor Unit
|
Yes
|
No
|
No
|
PSU
|
Power Supply Unit
|
Yes
|
Yes, One unit at a time to support redundancy
|
Yes, One unit at a time to support redundancy
|
ACS_A
|
AC Section Single Phase (M8000)
|
Yes
|
No
|
No
|
ACS_B
|
AC Section Single Phase (M9000) and Optional Dual
Power Feed Power Cabinet
|
Yes
|
No
|
No
|
ACS_C
|
AC Section Single Phase Dual Power Feed Option (M8000)
|
Yes
|
No
|
No
|
ACS_D
|
AC Section (3-Phase Dual Power Feed)
|
Yes
|
No
|
No
|
ACSTPH_A
|
M8000 3-Phase Delta Dual feed
|
Yes
|
No
|
No
|
ACSTPH_B
|
M8000 3-Phase Star Dual feed
|
Yes
|
No
|
No
|
ACSTPH_C
|
M9000 3-Phase Delta Dual feed
|
Yes
|
No
|
No
|
ACSTPH_D
|
M9000 3-Phase Star Dual feed
|
Yes
|
No
|
No
|
FAN_A
|
3 Fan Unit
|
Yes
|
Yes, One unit at a time to support redundancy
|
Yes, One unit at a time to support redundancy
|
FAN_B
|
2 Fan Unit
|
Yes
|
Yes, One unit at a time to support redundancy
|
Yes, One unit at a time to support redundancy
|
BP_A
|
Backplane (M8000)
|
Yes
|
No
|
No
|
DDC_A
|
DC-DC Converter (only found in M8000)
|
Yes
|
Yes
|
Yes
|
BP_B
|
Backplane (M9000)
|
Yes
|
No
|
No
|
PSUBP_A
|
PSU Backplane (M9000)
|
Yes
|
No
|
No
|
PSUBP_B
|
PSU Backplane (M8000)
|
Yes
|
No
|
No
|
FANBP_A
|
Fan Backplane (M9000)
|
Yes
|
No
|
No
|
FANBP_B
|
Fan Backplane (M9000)
|
Yes
|
No
|
No
|
FANBP_C
|
Fan Backplane (M8000)
|
Yes
|
No
|
No
|
MEDBP
|
Media Backplane
|
Yes
|
No
|
No
|
SWBP
|
Switch Backplane
|
Yes
|
No
|
No
|
RDPF
|
Rack Mountable Dual Feed Option (M8000)
|
Yes
|
No
|
No
|