Solution Type  Technical Instruction Sure

Solution  1003966.1 :   Performance Data Collection for Sun StorEdge[TM] 6130 and Sun StorageTek [TM] 6140/6540 Arrays  


Related Items
  • Sun Storage Flexline 380 Array
  •  
  • Sun Storage Flexline 240 Array
  •  
  • Sun Storage 2510 Array
  •  
  • Sun Storage 2540 Array
  •  
  • Sun Storage Flexline 280 Array
  •  
  • Sun Storage 6140 Array
  •  
  • Sun Storage Common Array Manager (CAM)
  •  
  • Sun Storage 2530 Array
  •  
  • Sun Storage 6540 Array
  •  
  • Sun Storage 6130 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage Software>Modular Disk Device Software
  •  

PreviouslyPublishedAs
205545


Applies to:

Sun Storage 6130 Array - Version: Not Applicable and later   [Release: N/A and later ]
Sun Storage 6140 Array - Version: Not Applicable and later    [Release: N/A and later]
Sun Storage 6540 Array - Version: Not Applicable and later    [Release: N/A and later]
Sun Storage 2510 Array - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Storage 2530 Array - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
All Platforms

Goal

Description

This document reviews methods for collecting performance statistics RAID Arrays
that can be managed using Sun StorageTek[TM] Common Array Manager (CAM).

It is intended to provide an overview of the statistics collected.

Solution


Steps to Follow
Please review the steps below to manage the performance collection.

Turning On Performance Collection

When turning on performance collection, there are three items to set:

Polling Interval:

Set for 1, 5, or 15 minutes. At this interval, the array will be contacted for new array data for all fields, and the management software will be updated with
the new statistics. Calculations for statistics will be made over this interval.

Data Retention Period:

Set for 1 hour, 2 hours, 4 hours, 1 day, or forever. This setting dictates how long the Peak data will be listed in the output collected. This only affects the collection of peak data until collection is turned off.

Baseline Time: (only for 2510 iSCSI based storage arrays with 7.35 firmware or later)

Clicking the Set Baseline button sets the baseline time to the current array system time, and the counters will display based on the values at that time.

Changing State via sscs CLI

sscs modify -a array --status on|off --poll 1|5|15 --retention forever|1HR|2R|4HR|1DAY performance

example:

sscs modify -a array --status on --poll 1 --retention 1HR

You can list these settings with :

sscs list -a array -T performance
Array: array
State: On
Polling Interval: 1 minute
Data Retention Period: 1 hour

Changing State via sscs CLI for iSCSI Performance

(2510 with 7.35 firmware or later)

sscs modify -a array --status on|off --poll 1|5|15 --retention forever|1HR|2R|4HR|1DAY --baseline true|false iperformance
NOTE: For 2510, both resource-type keyword "iperformance" and "performance" can be used to change state for data collection.

Example:

# sscs modify -a array --status on --poll 5 --retention forever --baseline true iperformance

You can list these settings with:

# sscs list -a array --settings iperformance
Array: array
  State:                  On
  Polling Interval:       5 minutes
  Data Retention Period:  Forever

ARRAY NAME: array
==================================================  
                                                    

BASELINE STATISTICS
======================                              
Controller A Baseline Time: March 3, 2010 2:28:38 PM EST
Controller B Baseline Time: March 3, 2010 2:29:14 PM EST

:
  : (etc...)
  :

Changing State via Browser

In the left-hand menu:
1) Expand Storage Systems
2) Expand Your Array Name
3) Expand Administration
4) Click Performance Monitoring

In the main window:
5) Check Performance Monitoring Enabled
6) Select Polling Interval
7) Select Data Retention Period
8) Click Save

NOTE: If array is 2510 iSCSI, click Set Baseline button to set baseline time in this window

Statistics Collection

Statistics can be collected at any time via any interface after monitoring
has been enabled, and at least one polling interval has gone by.

Statistics can be collected at the overall array level, per controller level, or per volume.

Array Statistics Collection

Collecting via Browser:

1) Expand Storage Systems
2) Expand Your Array Name
3) Expand Administration
4) Click Performance Monitoring

Collecting via sscs CLI

sscs list -a array --type array_stats performance

Collecting via sscs CLI for 2510

sscs list -a array --type array_stats --baseline true|false iperformance

Controller Statistics Collection

Collecting via Browser:

1) Expand Storage Systems
2) Expand Your Array Name
3) Expand Physical Devices
4) Click Controllers
5) Click View Performance Statistics button

 

sscs CLI

sscs list -a array --type controller_stats performance

Collecting via sscs CLI for 2510:

sscs list -a array --type controller_stats --baseline true|false iperformance

Volume Statistics Collection

Collecting via browser

1) Expand Storage Systems
2) Expand Your Array Name
3) Click Volumes
4) Click View Performance Statistics button

Collecting via sscs CLI:

sscs list -a array --type volume_stats -g hostgrp -h host -v volume performance

Collecting via sscs CLI for 2510:

sscs list -a array --type volume_stats -g hostgrp -h host -v volume --baseline true|false iperformance


NOTE: The hostgrp, volume, and host values may be comma delimited for listing multiple hosts, hostgroups, or specific volumes. Without these options, the output will list all array volumes and their performance statistics.

Available Statistics

The statistics available are the same for any collection. They are defined as
follows for a given object name for the given interval:

Statistic Definition
TOT IOPS Total IO's Per Second
READ % Percent of Total IOPS that were reads
WRITE% Percent of Total IOPS that were writes
TOT DATA Total Amount of Data transferred in KB
AVG R SIZE Average Read Size in KB
READS/s Number of Reads per second
PEAK R/s The highest number of Reads per Second during the retention period
AVG W SIZE Average Write size in KB
WRITES/s Number of Writes per second
PEAK W/s The highest number of Writes per Second during the retention period
CACHE% Read Cache Hit Percentage

Additional Statistics for 2510 Arrays

The following table describes the fields on the iSCSI Ethernet-MAC Performance Statistics page.

FieldIndicates
Controller A boot TimeDate and time when Controller A was last booted
Controller B boot TimeDate and time when Controller B was last booted
MAC Transmit Statistics
PortThe iSCSI port used to transmit and receive data
FFrame Count
B
Byte Count
MF
Multicast frame count
BF
Broadcast frame count
PF
Pause frame count
CF
Control frame count
FDF
Frame Deferral Count
FED
Frame excess deferral count
FLC
Frame late collisions count
FA
Frame abort count
FSC
Frame single collision count
FMC
Frame multiple collision count
FC
Frame collisions count
FDR
Frame Dropped Count
JF
Jumbo Frame count
MAC Receive Statistics
Port
iSCSI port used to transmit and receive data
F
Frame Count
B
Byte Count
MF
Multicast Frame Count
BF
Broadcast Frame Count
PF
Pause Frame Count
CF
Control Frame Count
FLE
Frame Length error count
FDR
Frame Dropped count
FCRCE
Frame CRC error count
FEE
Frame Encoding Error count
LFE
Large frame error count
SFE
Small frame error count
J
Jabber count
UCC
Unknown control frame count
CSE
Carrier Sense error count

Product

Sun StorageTek 6540 Array
Sun StorageTek 6140 Array
Sun StorageTek 6130 Array (SATA)
Sun StorageTek 6130 Array

Internal Comments
For internal Sun use only.

There is no user interface for real time collection of data. The
statistics are calculated based on the delta between the points of the
polling interval.
flx380, 2510, 2540, 2530, 2500, 6000, 6180, 6580, 6780, flx240, flx280, 6130, 6140, 6540, performance, sscs, CAM


Date: 2010-04-23
User: DeCotis
Comment: Changed Title. Updated product list and keywords. Added information about 2510 performance collections



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback