Asset ID: |
1-71-1003749.1 |
Update Date: | 2009-11-18 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1003749.1
:
Sun Fire[TM] V20z and V40z server: SP and onboard NIC LEDs status information
Related Items |
- Sun Fire V20z Server
- Sun Fire V40z Server
|
Related Categories |
- GCS>Sun Microsystems>Servers>x64 Servers
|
PreviouslyPublishedAs
205282
DescriptionThis document details the following SP and onboard network interface card(NIC) LED status information, for both the Sun Fire[TM] V20z and V40z servers:
Network Interface Ports:
Network Activity
Gigabit indication
100Mb indication
Link Status indication
Service Processor Management Ports:
FDX/Collision
Link Speed
Steps to FollowRefer to the "Sun Fire Quick Reference" label glued to the underside of the top
chassis cover, for more details:
- The "Motherboard Indicators, Switches, and Jumpers" section: shows the
approximate location of the LEDs.
- The "Power Indicators" section: gives a short description of the LED status.
Gigabit 0 connector, bottom, viewed from rear
|
Description |
Right |
Traffic/Activity |
Left |
Gigabit indicator |
LED indicators on Motherboard |
D34 |
100Mbps indicator |
D35 |
Link indicator |
Gigabit 1 connector, top, viewed from rear
|
Description |
Right |
Traffic/Activity |
Left |
Gigabit indicator |
LED indicators on Motherboard |
D36 |
100Mbps indicator |
D37 |
Link indicator |
Traffic/Activity: On = traffic is occurring.
Gigabit indicator: On = Gigabit mode is active.
100Mbps indicator: On = 100 Megabit mode is active.
Link indicator: On = active link is established.
MGMT connector, Port 1 (top), viewed from rear
|
Description |
Right |
FDX/Collision |
Left |
Link Speed |
MGMT connector, Port 2 (bottom), viewed from rear
|
Description |
Right |
FDX/Collision |
Left |
Link Speed |
FDX/Collision Indicator LED:
On = Link operation in full-duplex mode
Blinking = Link operating in half-duplex mode with collisions detected
Off = Link inoperative or operating in half-duplex mode with no collisions dected
Link Speed Indicator LED:
On = Link operating at 100 Mbps
Off = Line inoperative or operating at 10 Mbps
ProductSun Fire V20z Server
Sun Fire V40z Server
Internal Comments
Audited/updated 11/17/09 -
[email protected], x64 Content Team
link status, 100Mb, 1Gb, network activity, LED, SP
Previously Published As
83146
Change History
Date: 2006-03-07
User Name: 25440
Action: Approved
Comment: Minor changes (MbpS -> Mbps throughout for consistency). Publishing.
Version: 6
Date: 2006-03-07
User Name: 25440
Action: Accept
Product_uuid
1acc55b3-4b82-11d8-99fc-080020a9ed93|Sun Fire V20z Server
4726b78d-56d2-11d8-9e3a-080020a9ed93|Sun Fire V40z Server
Attachments
This solution has no attachment