Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1003696.1 : Sun Fire[TM] v60/v65 memory DIMM InfoDoc
PreviouslyPublishedAs 205214 Description This document contains information for diagnosing, testing, and resolving memory related issues in Sun Fire[TM] v60/65x systems. Steps to Follow Causes and Solutions Fault : Not all RAM can be seen by the system. Cause 1 : The system has disabled the bank during its first ever POST, but it can be cleared by doing the procedure below. Cause 2 : Must have 2 x 512mb DIMMs installed in bank 1. Cause 3 : Faulty DIMMs permanently disabling a DIMM socket. Cause 4 : Faulty DIMM sockets on system board. Resolution Solution 1 : Power on system Press F2 <setup> when logo appears Select - Advanced Select - Memory Configuration you should see which banks are installed and if they have been disabled. Select - Change 'Extended Memory Test' to every location and 'Memory Retest' to enabled. Press F10 to save and exit, then power cycle the system. The system will retest all installed RAM and should enable the previously disabled RAM banks. Solution 2: Install memory in pairs, beginning with Bank 1, Slots 1A and 1B. Solution 3: Replace DIMM. Some DIMMs can cause the system board slot which they have been installed into to be become permanently faulty. Solution 4: Replace system board. General Info Install memory in pairs, beginning with Bank 1, Slots 1A and 1B. DIMM failure LEDs are located between the DIMM sockets and CPU 1. An illuminated LED indicates a double-bit DIMM error. Product Sun Fire V65x Server Sun Fire V60x Server Sun Fire V60x Compute Grid Rack System sunfire, v60, v65, memory, faults, troubleshooting Previously Published As 78463 Change History Date: 2004-10-07 User Name: 7058 Action: Approved Comment: replaced all occurrences of dimm with DIMM, ram with RAM, etc. Corrected typos and minor grammar errors. Fixed &andash problem Trademarks in place. OK to publish now. Version: 4 Date: 2004-10-07 User Name: 7058 Action: Accept Comment: Version: 0 Date: 2004-10-07 User Name: 87288 Action: Approved Comment: Document has been evaluated. it is OK. Version: 0 Product_uuid 079e9bbc-0ee3-11d7-8c50-f1061905b56f|Sun Fire V65x Server 03728cec-0ee3-11d7-9be8-dd41f651e0a3|Sun Fire V60x Server 6a386040-356d-11d7-989c-cd4a3a4ab304|Sun Fire V60x Compute Grid Rack System Attachments This solution has no attachment |
||||||||||||
|