Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1003656.1
Update Date:2010-07-06
Keywords:

Solution Type  Technical Instruction Sure

Solution  1003656.1 :   Sun Fire[TM] 1280,2900,3800,4800,4810,4900,6900: Action plan when a [DOM] message is reported by the System Controller  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 4810 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
205165


Description
Expected action plan when a [DOM] is reported by the System Controller from a Sun Fire[TM] [1280/2900/3800/4800/4810/4900/6900]

Steps to Follow
A FRU is expected to be repaired, review complete message to ensure correct FRU is identified and replaced.
Example 1:
[DOM] Event: SF6800.L2TAG.CE.17
CSN: 044M347B DomainID: A ADInfo: 1.SF-SOLARIS-DE.Trang
Time: Mon Jul 19 15:58:30 PDT 2004
FRU-List-Count: 1; FRU-PN: 5014362; FRU-SN: 004419; FRU-LOC: /N0/SB5/P3
Recommended-Action: Service action required
Action: Repair SB5 (P3 is not a FRU and is part of SB5)
Example 2:
[DOM] Event: SF6800.L2SRAM.SERD.f.1b.10040000000091.f4470000
CSN: 044M347B DomainID: A ADInfo: 1.SF-SOLARIS-DE.5_10_on10-gate:05/29/2003
Time: Mon Jun 02 23:34:59 PDT 2003
FRU-List-Count: 1; FRU-PN: 3704125; FRU-SN: 090K01; FRU-LOC: /N0/SB3/P3/E0
Recommended-Action: Service action required
Action: Repair SB3 (P3/E0 is not a FRU and is part of SB3)


Product
Sun Fire V1280 Server
Sun Fire E6900 Server
Sun Fire E4900 Server
Sun Fire E2900 Server
Sun Fire 6800 Server
Sun Fire 4810 Server
Sun Fire 4800 Server
Sun Fire 3800 Server

Internal Comments
Audited/updated 11/24/09 - [email protected], Mid-Range Server Content Team

DOM SERD L2TAB, DOM, dom, SC, system controller
Previously Published As
81300

Change History
Date: 2005-04-24
User Name: 71396
Action: Approved
Comment: Performed final review of article.

Updated product name and trademarking.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback