Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1003656.1 : Sun Fire[TM] 1280,2900,3800,4800,4810,4900,6900: Action plan when a [DOM] message is reported by the System Controller
PreviouslyPublishedAs 205165 Description Expected action plan when a [DOM] is reported by the System Controller from a Sun Fire[TM] [1280/2900/3800/4800/4810/4900/6900] Steps to Follow A FRU is expected to be repaired, review complete message to ensure correct FRU is identified and replaced. Example 1: [DOM] Event: SF6800.L2TAG.CE.17 CSN: 044M347B DomainID: A ADInfo: 1.SF-SOLARIS-DE.Trang Time: Mon Jul 19 15:58:30 PDT 2004 FRU-List-Count: 1; FRU-PN: 5014362; FRU-SN: 004419; FRU-LOC: /N0/SB5/P3 Recommended-Action: Service action required Action: Repair SB5 (P3 is not a FRU and is part of SB5) Example 2: [DOM] Event: SF6800.L2SRAM.SERD.f.1b.10040000000091.f4470000 CSN: 044M347B DomainID: A ADInfo: 1.SF-SOLARIS-DE.5_10_on10-gate:05/29/2003 Time: Mon Jun 02 23:34:59 PDT 2003 FRU-List-Count: 1; FRU-PN: 3704125; FRU-SN: 090K01; FRU-LOC: /N0/SB3/P3/E0 Recommended-Action: Service action required Action: Repair SB3 (P3/E0 is not a FRU and is part of SB3) Product Sun Fire V1280 Server Sun Fire E6900 Server Sun Fire E4900 Server Sun Fire E2900 Server Sun Fire 6800 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Internal Comments Audited/updated 11/24/09 - [email protected], Mid-Range Server Content Team DOM SERD L2TAB, DOM, dom, SC, system controller Previously Published As 81300 Change History Date: 2005-04-24 User Name: 71396 Action: Approved Comment: Performed final review of article. Updated product name and trademarking. Attachments This solution has no attachment |
||||||||||||
|