Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1003330.1 : Sun Fire[TM] V480/V880 Firmware Error: RAM-CRC COPY FAILURE
PreviouslyPublishedAs 204622 Description Sun Fire[TM] V480/V880 Firmware Error: RAM-CRC COPY FAILURE Steps to Follow Some customers receive the following error on reboot after upgrading either POST or OBP (but not both, although they are included in the same patch): RAM-CRC COPY FAILURE This error is generated when the Open Boot Prom tries to verify proper installation of its matching POST image but the POST image currently installed is NOT from the same installation and therefore fails the CRC check. The OBP and POST/OBDiag firmware is contained in the same patch. During installation, the script will ask if it should upgrade both OBP and POST. If the customer answers 'no', only the OBP upgrade will take place which causes the OBP firmware and POST firmware to be mismatched, thus failing the CRC check upon reboot after patch installation. If the customer answers 'yes' to this question, both OBP and POST/OBDiag will be upgraded and the CRC check will pass on reboot. The current patch number to upgrade OBP/POST is 113034 for a V480, and 112186 for a V880.
Product Sun Fire V880 Server Sun Fire V480 Server Internal Comments The following is strictly for the use of Sun employees: firmware, upgrade, POST, OBP Previously Published As 49112 Change History Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : Robin Dole comment : No comment date : Jan 9, 2003 Attachments This solution has no attachment |
||||||||||||
|