Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1003250.1
Update Date:2010-09-16
Keywords:

Solution Type  Technical Instruction Sure

Solution  1003250.1 :   Dual hosting a Sun StorEdge[TM] A3x00 array  


Related Items
  • Sun Storage A3000 Array
  •  
  • Sun Storage A3500 SCSI Array
  •  
  • Sun Storage A3500 FC Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
204466


Steps to Follow

If your customer is attempting to dual host a A3x00 array in a 1X5 configuration, the 2 controllers in the array module must be set to independent mode. You can check this by running the following command after the RAID Manager (RM6) software is installed.

# storutil -c nasc_001 -d
nasc_001:
Controller A: 1T71525033 ( c3t5d0 )
Controller B: 1T93500060 ( c2t4d1 )
Independent Controller Configuration: OFF

To make changes to this configuration you use the same command with different options.

#storutil -c nasc_001 -i on
storutil succeeded!


Product
Sun StorageTek A3500 Array
Sun StorageTek A3000
Sun StorageTek A3500 FC Array

Internal Comments

Previously Published As
26823

Change History
Date: 2006-01-19
User Name: 31620
Action: Update Canceled
Comment: *** Restored Published Content *** SSH AUDIT
Version: 0
Date: 2006-01-19
User Name: 31620
Action: Update Started
Comment: SSH AUDIT
Version: 0
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : George Bolduc
comment : Looks fine.
date : May 10, 2001



updated by : Tim Warembourg
comment : This was written after a problem he helped me with
date : May 9, 2001



updated by : Mike Young
comment : No comment
date : May 8, 2001



updated by : Mike Young
comment : Article created.
date : May 7, 2001
Version: 0
Product_uuid
2a8022d4-0a18-11d6-8043-ee5a180fdb7f|Sun StorageTek A3500 Array
2a7ca41a-0a18-11d6-82f2-e96014c515ea|Sun StorageTek A3000
b648cdf0-efb8-4d4f-93d4-b17c1baf1935|Sun StorageTek A3500 FC Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback