Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1003101.1
Update Date:2010-09-13
Keywords:

Solution Type  Technical Instruction Sure

Solution  1003101.1 :   Sun StorEdge[TM] A3000/A3500: Correct power down, power up order  


Related Items
  • Sun SPARCstorage RSM Array 2000
  •  
  • Sun Storage A3000 Array
  •  
  • Sun Storage A3500 SCSI Array
  •  
  • Sun Storage A3500 FC Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
204246


Description
The Sun StorEdge[TM] A3000 (formerly called the RSM 2000) and Sun StorEdge[TM] A3500 arrays must be powered down and powered up in a specific order so as not to cause a channel failure or loss of configuration.


Steps to Follow
It is imperative that whenever the need arises to power cycle an entire array, the following steps are followed.
  1. Place the attached host system(s) at the ok prompt, with init 0 and power off.

  2. Power down the RDAC module (the part that contains the array's controllers).

  3. Power down the disk trays.

  4. Do whatever work is required on the array.

  5. Power up the disk trays and leave them running for 30 seconds.

  6. Power up the RDAC module.

  7. Power up the host system.

If the RDAC module is powered on before the disks are spun up, you run the risk of the disks reporting themselves with a 'Replaced' status.



Product
SPARCstorage RSM
Sun StorageTek A3500 Array
Sun StorageTek A3000
Sun StorageTek A3500 FC Array

Internal Comments
None.



power, RSM 2000, StorEdge A3000, A3500
Previously Published As
26929

Change History
Date: 2006-01-18
User Name: 31620
Action: Update Canceled
Comment: *** Restored Published Content *** SSH AUDIT
Version: 0
Date: 2006-01-18
User Name: 31620
Action: Update Started
Comment: SSH AUDIT
Version: 0
Date: 2005-08-05
User Name: 71396
Action: Approved
Comment: Performed final review of article.
Product_uuid
2a5b102a-0a18-11d6-85d3-d27213c4a92c|SPARCstorage RSM
2a8022d4-0a18-11d6-8043-ee5a180fdb7f|Sun StorageTek A3500 Array
2a7ca41a-0a18-11d6-82f2-e96014c515ea|Sun StorageTek A3000
b648cdf0-efb8-4d4f-93d4-b17c1baf1935|Sun StorageTek A3500 FC Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback