Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1002939.1 : How to check if the platform is system powered on, Sun Fire[TM] X2100 Servers
PreviouslyPublishedAs 204042 Description Description Summary: This document describes how to check if the is system is powered on via ipmitool and if you are local to the server. Symptoms:
Status of power in question Steps to Follow Steps to Follow Note: This document uses the optional service processor SMDC (Service Management Daughter Card) to get information of the system with the help of IPMI (Intelligent Platform Management Interface). Therefore this card needs to be installed and configured to follow the steps within this document. To get information on how to install and configure the optional SMDC, please refer to Sun Fire X2100 Server User Guide, Part No. 819-3721, Appendix C "Using the Optional Service Processor" Available at: http://www.oracle.com/technetwork/documentation/oracle-x86-servers-190077.html 1. Verify system power status is ON via ipmitool.
# ipmitool -I lanplus -U Admin -H <SMDC IP address> chassis status System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : always-off Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false
2. Verifying system power if you are local to the server.
For further Information about LED states refer to Sun Fire X2100 Server Getting Started Guide, Part No. 819-3720, Chapter 1.6 "Powering On the Server" Available at: http://www.oracle.com/technetwork/documentation/oracle-x86-servers-190077.html Product Sun Fire X2100 Server Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the "Document Feedback" alias(es) listed below:
Normalization team alias: [email protected] x64, normalized, X2100, Power Previously Published As 91577 Change History Date: 2007-12-21 User Name: 31620 Action: Approved Product_uuid 28c0502a-fd60-11d9-a8ca-080020a9ed93|Sun Fire X2100 Server Attachments This solution has no attachment |
||||||||||||
|