Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1002807.1
Update Date:2011-03-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1002807.1 :   Sun SPARC[TM] Enterprise M4000 and M5000 Server Device Paths  


Related Items
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>OPL Servers
  •  

PreviouslyPublishedAs
203831


Applies to:

Sun SPARC Enterprise M4000 Server
Sun SPARC Enterprise M5000 Server
All Platforms

Goal

The intent of this document is to provide the reader with an overview of how the Sun SPARC(R) Enterprise M4000 and M5000 system device paths are arranged.

Solution

There are two attributes that impact how the Sun SPARC Enterprise M4000 and Sun SPARC Enterprise M5000 device paths are arranged. The attributes are the I/O architecture and the assignment of the Logical System Board (LSB). When allocating resources to a domain through the Domain Control List (DCL), OPL's access control list, these resources are also assigned to a Logical System Board (LSB).
More information on LSB's can be found in <Document 1011446.1> Sun SPARC Enterprise Mx000 Servers Logical System Board (LSB) and
Sun SPARC Enterprise M4000/M5000/8000/M9000 Server Administration Guide document body and Appendix A.

The following is a graphical representation of the Sun SPARC  Enterprise M4000 and Sun SPARC  Enterprise M5000 IOU0 device path layout:

|----- /pci@[LSB1]0,600000/pci@0 (Base Path)

     |-- ../pci@8/pci@0/scsi@1/disk0 IOU0 HD0

     |-- ../pci@8/pci@0/scsi@1/disk1 IOU0 HD1

     |-- ../pci@8/pci@0/scsi@1/disk3 DVD (IOU0 only)

     |-- ../pci@8/pci@0/scsi@1/tape DAT (IOU0 only)

     |-- ../pci@8/pci@0/network@2 BGE0 (IOU network connection)

     |-- ../pci@8/pci@0/network@2,1 BGE1 (IOU network connection)

     |-- ../pci@8/pci@0,1 Slot 0 (PCI-X)

     |-- ../pci@0/pci@9 Slot 1 (PCIe)

 |----- /pci@[LSB1]1,700000 Slot 2 (PCIe)

 |----- /pci@[LSB2]2,600000 Slot 3 (PCIe)

 |----- /pci@[LSB2]3,700000 Slot 4 (PCIe)


Note:  When a Physical System Board (PSB) is in UniMode, [LSB1]  it is the same as [LSB2].  When the PSB is placed in QuadMode, [LSB1] it is NOT the same as  [LSB2] when the resources are in the same domain.  It is possible however that when in QuadMode, [LSB1] could be the same as [LSB2] when the resources are in different domains.

The Sun SPARC  Enterprise M5000 IOU1 device path layout is very similar to the IOU0 device path with the exception that there is no DVD and DAT connected to IOU1.  The following is a graphical representation of the Sun SPARC  Enterprise M5000 IOU1 device path layout:

|----- /pci@[LSB3]0,600000/pci@0 (Base Path)

     |-- ../pci@8/pci@0/scsi@1/disk0 IOU1 HD2

     |-- ../pci@8/pci@0/scsi@1/disk1 IOU1 HD3

     |-- ../pci@8/pci@0/network@2 BGE0 (IOU network connection)

     |-- ../pci@8/pci@0/network@2,1 BGE1 (IOU network connection)

     |-- ../pci@8/pci@0,1 Slot 0 (PCI-X)

     |-- ../pci@0/pci@9 Slot 1 (PCIe)

 |----- /pci@[LSB3]1,700000 Slot 2 (PCIe)

 |----- /pci@[LSB4]2,600000 Slot 3 (PCIe)

 |----- /pci@[LSB4]3,700000 Slot 4 (PCIe)

 

Note:  Just as with IOU0, when a Physical System Board (PSB) is in UniMode, the IOU1 [LSB3]  is the same as [LSB4].  When the PSB is placed in QuadMode, IOU1 [LSB3] is NOT the same as  [LSB4] when the resources are in the same domain.  It is possible however that when in QuadMode, IOU1 [LSB3] could be the same as [LSB4] when the resources are in different domains.

The following table represents the same device path information presented in a table format along with the UniMode and QuadMode assignments:

Sun SPARC  Enterprise M4000 and Sun SPARC  Enterprise M5000 IOU0 Table:

Device

Type

UniMode

QuadMode

Device Path

IOU0 HD0

SAS/SATA

XSB XX-0

XSB XX-0

/pci@[LSB1]0,600000/pci@0/pci@8/pci@0/scsi@1/disk0

IOU0 HD1

SAS/SATA

XSB XX-0

XSB XX-0

/pci@[LSB1]0,600000/pci@0/pci@8/pci@0/scsi@1/disk1

CD/DVD

SCSI

XSB XX-0

XSB XX-0

/pci@[LSB1]0,600000/pci@0/pci@8/pci@0/scsi@1/disk3

DAT

SCSI

XSB XX-0

XSB XX-0

/pci@[LSB1]0,600000/pci@0/pci@8/pci@0/scsi@1/tape

BGE0

10/100/1000 HDX/FDX

XSB XX-0

XSB XX-0

/pci@[LSB1]0,600000/pci@0/pci@8/pci@0/network@2

BGE1

10/100/1000 HDX/FDX

XSB XX-0

XSB XX-0

/pci@[LSB1]0,600000/pci@0/pci@8/pci@0/network@2,1

IOU Slot 0

PCI-X

XSB XX-0

XSB XX-0

/pci@[LSB1]0,600000/pci@0/pci@8/pci@0,1

IOU Slot 1

PCIe

XSB XX-0

XSB XX-0

/pci@[LSB1]0,600000/pci@0/pci@9

IOU Slot 2

PCIe

XSB XX-0

XSB XX-0

/pci@[LSB1]1,700000

IOU Slot 3

PCIe

XSB XX-0

XSB XX-1

/pci@[LSB2]2,600000

IOU Slot 4

PCIe

XSB XX-0

XSB XX-1

/pci@[LSB2]3,700000

Sun SPARC  Enterprise M5000 IOU1 Table:

Device

Type

UniMode

QuadMode

Device Path

IOU1 HD2

SAS/SATA

XSB XX-0

XSB XX-0

/pci@[LSB3]0,600000/pci@0/pci@8/pci@0/scsi@1/disk0

IOU1 HD3

SAS/SATA

XSB XX-0

XSB XX-0

/pci@[LSB3]0,600000/pci@0/pci@8/pci@0/scsi@1/disk1

BGE0

10/100/1000 HDX/FDX

XSB XX-0

XSB XX-0

/pci@[LSB3]0,600000/pci@0/pci@8/pci@0/network@2

BGE1

10/100/1000 HDX/FDX

XSB XX-0

XSB XX-0

/pci@[LSB3]0,600000/pci@0/pci@8/pci@0/network@2,1

IOU Slot 0

PCI-X

XSB XX-0

XSB XX-0

/pci@[LSB3]0,600000/pci@0/pci@8/pci@0,1

IOU Slot 1

PCIe

XSB XX-0

XSB XX-0

/pci@[LSB3]0,600000/pci@0/pci@9

IOU Slot 2

PCIe

XSB XX-0

XSB XX-0

/pci@[LSB3]1,700000

IOU Slot 3

PCIe

XSB XX-0

XSB XX-1

/pci@[LSB4]2,600000

IOU Slot 4

PCIe

XSB XX-0

XSB XX-1

/pci@[LSB4]3,700000

A significant piece of the understanding the complete device path is knowing which LSB the XSB resource has been assigned.  Allowing a XSB resource to be part of a domain through the DCL at the same time assigning the resource to a LSB has the following impact on device path numbering (ie. the  [LSB1]  and  [LSB2]  values of the device path):

LSB Assignment

LSB1-4 Value

LSB Assignment

LSB1-4 Value

0

No Value

8

8

1

1

9

9

2

2

10

a

3

3

11

b

4

4

12

c

5

5

13

d

6

6

14

e

7

7

15

f

For more information on Sun SPARC  Enterprise M8000/M9000 device paths, see <Document 1004116.1>Sun SPARC Enterprise M8000 and M9000 Device Paths.
For more information on External I/O Expansion Unit device paths, see <Document 1005313.1> Sun SPARC External I/O Expansion Unit Device Paths.

Actual device paths may be seen using some of the following methods:
OBP:    show-devs command
Solaris: /etc/path_to_inst file
Solaris: prtpicl command
Solaris: prtdiag -v  command




To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - M Series Servers

References

<NOTE:1004116.1> - Sun SPARC(R) Enterprise M8000 and M9000 Device Paths
<NOTE:1005332.1> - Sun SPARC(R) External I/O Expansion Unit Device Paths
<NOTE:1011446.1> - Sun SPARC Enterprise Mx000 Servers : Logical System Board (LSB)
<NOTE:1019730.1> - Sun SPARC(R) Enterprise M3000 Server Device Paths
http://download.oracle.com/docs/cd/E19170-01/821-2794-10/index.html

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback