Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1002712.1
Update Date:2010-08-27
Keywords:

Solution Type  Technical Instruction Sure

Solution  1002712.1 :   Validating Sun StorEdge[TM] 6920 Profile Deletion  


Related Items
  • Sun Storage 6920 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
203721


Description
The purpose of this document is to provide basic steps for profile deletion for the 6920 array, via the Browser User Interface(BUI) or sscs Command Line Interface(CLI).

Content will be limited to a basic usage using the CLI or BUI interfaces
for deleting profiles, and provide help with some usage failure scenarios
for this activity. Consider reviewing some of the following documents if you
are looking to perform actions beyond the scope of this document:



Steps to Follow
Validating Sun StorEdge[TM] 6920 Profile Deletion:

A. Validate that the profile is not a factory profile

Verify the type of profile. If it is listed as a Type of Factory, it cannot be deleted from the system. Reference document document <Document: 1007159.1> Validating Profile State and Status on a StorEdge 6920 [TM]

If the type of the profile is not Factory, continue to Step B.

B. Validate that the profile is not In Use

Verify the status of the profile. Reference document <Document: 1007159.1> Validating Profile State and Status on a StorEdge 6920 [TM]

If the Status shows In Use, then there is at least one Storage Pool
still using the profile, and must be deleted before the profile can be removed.

Reference document <Document: 1009823.1> Validating StorEdge(TM) 6920 Pool Deletion

If the Profile Status is Not In Use, continue Step C.

C. Profile Deletion Procedure

SSCS

usage;
sscs delete profile <string[,string...]>

  1. ./sscs delete profile test-profile
    You will not get any messages  if the deletion was successful.

BUI

  1. Click on Sun StorEdge(TM) Configuration Services link.
  2. Click on Logical Storage.
  3. Click on Profiles.
  4. Click on Test-Profile link.
  5. Click on Delete tab.
  6. Click on OK.
     You should now get the message "The Storage Profile test-profile was
deleted".

If you received a failure message, please go to Step D.

D. Deletion Failure

BUI
Message:
<profile> - Operation not supported

Action:
You attempted to delete a factory profile. See Step A.

Message:
<profile> - Item is in use

Action:
You attempted to delete an In Use profile. See Step B

Message:

E. Data Collection

  • 6920 Solution Extract, reference document <Document: 1003756.1> How to collect an extractor from a Sun StorEdge[TM] 6920 (2.x and 3.x)
  • The message given by SSCS or BUI(screen capture if possible)
  • The command used, if by SSCS
  • The input and selections for the new volume wizard in the BUI
  • The following sscs output:

sscs list profile
sscs list profile <profile_name>
sscs list pool
sscs list pool <pool name> (needed for sizing issues)

and contact Sun Support



Product
Sun StorageTek 6920 System

Internal Comments
Sun Support

This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

[email protected]


F. Validate that services are running properly on the SP


Reference document <Document: 1007129.1> Validating Services on a Sun StorEdge 6920 Service Processor



G. Escalate


Provide the following:



  • Description of what is not being displayed properly

  • Results of Step F.

  • Location of everything in Step E

The Knowledge Work Queue for this article is
KNO-STO-MIDRANGE_DISK

6920, delete, profile, normalized, Audited
Previously Published As
90542

Change History
Date: 2007-09-28
User Name: 7058
Action: Approved
Comment: Links OK.
metadata OK.
OK to publish.
Version: 4
Date: 2007-09-20
User Name: 85390
Action: Approved
Comment: I have corrected the ##### and populated it with the correct Info number and title.
Donald Masters
Version: 0
Date: 2007-09-20
User Name: 7058
Action: Rejected
Comment: I cannot publish this document for 2 reasons.
1. doc id 89105 is still in draft. Once that document is done with tech review, please resubmit and I will publish them together.
2. I cannot publish any doc with links to "#####" That is incomplete, and will frustrate customers. Please resubmit this doc once ##### is actually populated with document ID numbers and any interdependently linked docs are all in final review.


Attachments