Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1002664.1
Update Date:2011-04-13
Keywords:

Solution Type  Technical Instruction Sure

Solution  1002664.1 :   Sun StorEdge[TM] 6130 Firmware Matrix  


Related Items
  • Sun Storage 6130 Array
  •  
  • Sun Storage Common Array Manager (CAM)
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
203667
This article documents Sun StorEdge[TM] 6130 Array's components firmware baseline bundled in each corresponding CAM release and patched versions.

In this Document
  Goal
  Solution


Applies to:

Sun Storage 6130 Array
Sun Storage Common Array Manager (CAM) - Version: 5.0 and later    [Release: 5.0 and later]
All Platforms

Goal

This article documents Sun StorEdge[TM] 6130 Array's components firmware baseline bundled in each corresponding CAM release and patched versions.

This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware and management software compatibility.

For instructions to download CAM, please refer to <Document 1296274.1> How to Download Common Array Manager (CAM) Software and Patches.

Solution

Baseline / CAM Release Sun StorEdge 6130 Firmware
Patch Controller Expansion
Firmware NVSRAM CSM100 FC CSM100 SATA CSM200 FLA200 FC FLA300 FC FLC200 dSATA FLC200 iSATA
1.0 117856-10 06.10.09.15 N2882-610843-012 9627 no support no support no support
1.1 117856-14 06.10.09.16 N2882-610843-013 9627 9718
1.1 119513-01   9630  
1.2 117856-15 06.12.03.12 N2882-612843-003 9627 9721
1.2 controlled 06.12.03.14+ N2882-612843-003+ 9627 9722
1.3 117856-17 06.12.09.10 N2882-612843-003 9631 9722
1.3 117856-18
118185-14
06.12.09.10 N2882-612843-006a 9631 9722
1.3 117856-19
118185-15
06.12.10.11 N2882-612843-003a 9631 9722
2.0 117856-26 06.12.09.10b N2882-612843-003b 9631 9722
2.1 117856-27 06.12.09.10b N2882-612843-003b 9631 9722
Naming convention changed. Version following 2.1 is 5.0. There was no 3.x or 4.x.
5.0 117856-35 06.12.27.10 N2882-612843-008 9631 9726
5.0.1 117856-35 06.12.27.10 N2882-612843-008 9631 9726
5.0.2 117856-35 06.12.27.10 N2882-612843-008 9631 9726
5.1.0.10 117856-37 06.19.23.10c N2882-619843-001c 9643 9726 9884
5.1.0.11 117856-37 06.19.25.10d N2882-619843-001 9643 9726 9884
5.1.2.2 117856-37 06.19.25.10 N2882-619843-001 9643 9726 9884
5.1.3.2 117856-37 06.19.25.10 N2882-619843-001 9643 9726 9884
5.1.3.2 controlled 06.19.25.13e  
5.1.3.2 controlled 06.19.25.14e  
6.0.0.10 n/a 06.19.25.16 N2882-619843-001 9643 9726 9887 9330 9643 9565 9726
6.0.1.11 n/a 06.19.25.16 N2882-619843-001 9643 9726 9887 9330 9643 9565 9726
6.1.0.16 n/a 06.60.11.10f N288X-660843-003 9643 9726 98B4 9330 9643 9565 9726
6.1.1.16 n/a 06.60.11.10 N288X-660843-003 9643 9726 98B4 9330 9643 9565 9726
6.1.2.8 n/a 06.60.11.10 N288X-660843-003 9643 9726 98B4 9330 9643 9565 9726
6.2.0.13   06.60.11.10 N288X-660843-003 9681 9728 98C1 9330 9681 9566 9728
6.3.0   (CAM 6.3 was never released.)
6.4.0.10   06.60.11.10 N288X-660843-003 9681 9728 98C4 9330 9681 9566 9728
6.4.1.5   06.60.22.10 N288X-660843-003 9682 9728 98C4 9330 9682 9566 9728
6.5.0.10   06.60.22.10 N288X-660843-003 9682 9728 98C4 9330 9682 9566 9728
6.5.0.x controlled   N288X-660843-039g  
6.6.0.11h   06.60.22.10 N288X-660843-003 9682 9728 98D0 9330 9682 9566 9728
6.7.0.12   06.60.22.10 N288X-660843-003 9682 9728 98D0 9330 9682 9566 9728
6.7.0.13 (Windows Only) 144861-01 (CAM core patch for Windows only. Fixes CR6968739 J4410 reporting incorrect chassis serial number; and CR6972298 Win2008 undefined constant.)
Baseline / CAM Release Patch Firmware NVSRAM CSM100 FC CSM100 SATA CSM200 FLA200 FC FLA300 FC FLC200 dSATA FLC200 iSATA
Controller Expansion
Sun StorEdge 6130 Firmware
NOTE: Firmware shown as "controlled" are not publicly available and is only provided on a case-by-case basis as deemed necessary by support services.

+ Enables Remote Volume Mirror (RVM) feature. For approved config only. Requires 118164-04 and 118165-04.
a 117856-18 was needed for Sun StorEdge 5000 NAS Gateway Support, 117856-19 does not support it. However, mixing 06.12.10.11 (117856-19) and N2882-612843-006 (117856-18) is not supported bec. it was not tested for Sun Alert 102191.
b Baseline 2.0 and 2.1 incorrectly bundled the older 6130 firmware 06.12.09.10 and NVSRAM N2882-612843-003. If a 6130 array already has the newer 06.12.10.11 firmware or the newer NVSRAM N2882-612843-006, simply choose "Do Not Upgrade" when registering the array.
c Some interim build before 06.19.23.10 may have been released to some customers as temporary fix, these should be updated to 5.1 baseline or later ASAP.
d Sun StorEdge 5000 NAS Gateway bug fix.
e 06.19.25.13/23 and 06.19.25.14/.24 were early access releases of .16/26. Customers with this firmware should be updated to .16/26. Note that .14 contains all fixes in .13 and supersedes it.
f SE6130 (288X controller) does not support 7.10 firmware; 6.60 is the last release for this controller.
g Temporary fix in NVSRAM for CR6704575 PFA issue.
h CAM 6.6.0.11 host types do not match array's host region (CR6935284), affecting 2500, 6140, 6180, 6540, 6580/6780. This may result in either new mappings selecting the wrong host region, or user confused by the display and change existing mappings which was correct, to become wrong. CAM 6.6.0.12 through patch 14147[456]-01 was specifically released to resolve this bug.



Internal website for CAM supported array firmware matrix.
http://tsc-storage.us/products/CAM/matrix.html
This site is typically updated first before being edited for public consumption.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback