Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1002468.1 : Verify Battery
PreviouslyPublishedAs 203443 Description In order to provide you the most accurate fix, please validate that each statement under the symptoms below is true for your environment. These symptoms will hyperlink you into a relevant content that will - tell you how to validate the listed symptom and - how to fix the symptom if it is true for your environment. The listed symptoms are ordered in the most appropriate sequence to isolate the issue and be certain about the related fix. Please do not skip a step. Symptoms:
- Failed battery - Refreshing battery - Expired battery - Writethrough cache Steps to Follow Verify Battery NOTE: This is a sub-set of <Document: 1018272.1> : "Troubleshooting Sun StorEdge[TM] T3 hardware." The steps below will help to verify and resolve battery problems. POWER STATUS STATE SOURCE OUTPUT BATTERY TEMP FAN1 FAN2 ------ ------- --------- ------ ------ ------- ------ ------ ------ u1pcu1 ready enabled line normal normal normal normal normal u1pcu2 ready enabled line normal normal normal normal normal u2pcu1 ready enabled line normal normal normal normal normal u2pcu2 ready enabled line normal normal normal normal normal 1. Verify the battery is not refreshing by using the "refresh -s" command. Example for FW 2.x and below: purple15:/:<9>refresh -s
No battery refreshing Task is currently running.
PCU1 PCU2 ----------------------------------------------------------------- U1 Normal Normal U2 Normal Normal Current Time Mon Mar 26 10:16:28 2001 Next Refresh Fri Mar 30 14:00:00 2001 Example for FW 3.1.x and above: storage-t3b:/:<3>refresh -s
Current Date and Time: Mon Aug 14 09:42:34 GMT 2006
Next Scheduled Refresh: Mon Aug 28 02:00:25 GMT 2006
Battery State Last Health Check Warranty Expiration ------- ------- ---------------------------- ---------------------------- u1b1 normal Tue Jul 25 18:47:10 GMT 2006 Fri Aug 17 08:47:10 GMT 2007 u1b2 normal Tue Jul 25 22:38:15 GMT 2006 Thu Apr 26 13:38:15 GMT 2007 u2b1 normal Tue Jul 25 18:45:57 GMT 2006 Fri Apr 06 17:45:57 GMT 2007 u2b2 normal Tue Jul 25 22:38:34 GMT 2006 Thu Apr 26 13:38:34 GMT 2007 NOTE: Both examples do not have a refresh running. Product Sun StorageTek T3+ Array Sun StorageTek T3 Array Internal Comments Place Sun Internal-Use Only content here. This content will be published to internal SunSolve only. This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: [email protected] The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK. 2. If a refresh is not occurring, refer to <Document: 1017436.1> : "PREVENTIVE MAINTENANCE: Procedure for 3. If the battery is faulted and <Document: 1017436.1> : "PREVENTIVE MAINTENANCE: Procedure for 4. The Complete Guide to Battery Management for the Sun StorEdge T3, T3+, battery, fault, refresh, expired, failed, audited, normalized Previously Published As 86650 Change History Date: 2007-11-13 User Name: 7058 Action: Approved Comment: Reference to internal link in external section. Fixed. Version: 9 Date: 2007-11-13 User Name: 7058 Action: Update Started Comment: Fixing links pre-IBIS migration. Version: 0 Date: 2007-07-16 User Name: 7058 Action: Approved Comment: OK to publish. Dependencies fixed. Version: 8 Date: 2007-07-16 User Name: 88218 Action: Approved Comment: Document Technically Correct Version: 0 Attachments This solution has no attachment |
||||||||||||
|