Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1002211.1
Update Date:2010-07-06
Keywords:

Solution Type  Technical Instruction Sure

Solution  1002211.1 :   Serial Cable Pin-outs Between Annex[TM] and Certain Sun[TM] Hardware including SF6800  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Enterprise 220R Server
  •  
  • Sun Fire V1280 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
203126


Description
Serial cable pin-outs needed while utilizing an Annex[TM] Terminal Server to capture console output from T300, T3+, ALOM (eg. Netra[TM] 240), RJ45 serial port (eg. V1280) or RSC (Remote System Controle) (eg. Sun Enterprise[TM] 220R).

Steps to Follow
Pin-outs between an Annex and a T300:
 Annex RJ45              T300 RJ11
TXD 3 ----------------- 5 RXD
RXD 5 ----------------- 6 TXD
GND 6 ----------------- 4 GND
NB: set the port on the Annex to SOFTWARE HANDSHAKE instead of hardware handshake. Otherwise you will not get a connection.
__________________________________________________________________________
Pin-outs between an Annex and a T3+, ALOM or RJ45 serial port:
Annex RJ45              T3+ RJ45
RTS 1 ----------------- 8 CTS
DTR 2 ----------------- 7 DSR
TXD 3 ----------------- 6 RXD
DCD 4 ----|
RXD 5 ----------------- 3 TXD
GND 6 ----------------- 5 GND
DSR 7 ----------------- 2 DTR
CTS 8 ----------------- 1 RTS
NB: the cable is not symmetrical. One end is dedicated for the T3+ while the other can only be connected to the Annex.
__________________________________________________________________________
Pin-outs between an Annex and an RSC board:
Annex RJ45              RSC RJ45
RTS 1 ----------------- 8 CTS
DTR 2 ----------------- 7 DSR
TXD 3 ----------------- 6 RXD
DCD 4 ----|
RXD 5 ----------------- 3 TXD
GND 6 ----------------- 4 GND
DSR 7 ----------------- 2 DTR
CTS 8 ----------------- 1 RTS
NB: the cable is not symmetrical. One end is dedicated for the RSC while the other can only be connected to the Annex.


Product
Netra 240 Server
Sun Enterprise 220R Server
Sun Fire V1280 Server
Sun Fire E6900 Server
Sun Fire 6800 Server

annex, serial, pin layout, terminal concentrator, tc, ntc, rsc, alom
Previously Published As
78940

Change History
Date: 2008-01-08
User Name: 95826
Action: Update Canceled
Comment: *** Restored Published Content *** canceling update to allow migration to IBIS
Version: 0
Date: 2008-01-08
User Name: 95826
Action: Reassign
Comment: reassigning document to release it in order to allow migration to IBIS
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback