Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1002199.1 : problems with ftp to Sun StorEdge[TM] T3/6120 after fw upgrade
PreviouslyPublishedAs 203111 Description After upgrading the firmware using the t3.sh/6120.sh script, ftp to the array is not in interactive mode or fails with a "Macro definition missing null line terminator" error. Steps to Follow When ftping to the array it looks like it is still attempting to run the upgrade script and user cannot login. # ftp 10.0.0.36 Connected to 10.0.0.36. 220 10.0.0.36 T300 FTP server ready. Name (10.0.0.36:root): 331 Password required for root. Password: 230 User root logged in. bin 200 Type set to I. prompt Interactive mode off. cd / 250 CWD command successful. lcd /tmp/upload.27957 /tmp/upload.27957: No such file or directory mkdir etc 550 etc: file exists. mkdir web 550 web: file exists. mkdir web/snmp 550 web/snmp: file exists. mput ep*.bin mput v118*.bin mput lpc*.* cd etc 250 CWD command successful. lcd files/etc files/etc: No such file or directory rename schd.conf sch_old.conf 350 File exists, ready for destination name 550 rename: file exists. put schd.conf schd.conf: No such file or directory cd ../web 250 CWD command successful. lcd ../web ../web: No such file or directory mput * cd snmp 250 CWD command successful. lcd snmp snmp: No such file or directory mput * quit 221 Goodbye. You may also receive the following error when attempting to ftp to your array: Connected to t3b0. 220 192.168.0.40 pSOSystem FTP server (@(#)(#)pVER IA/MIPS, Version 3.1.0, Built on 12/03/1999) ready. Macro definition missing null line terminator. 221 Goodbye. ftp> It is possible that the script did not correctly clean up the .netrc file used to upgrade the firmware. Check for the file in /.netrc or ~/.netrc and remove it. Login as the same user used to run the script # cd # ls -a .net* If this returns "No match" then the file does not exist. If this returns ".netrc", remove the file # rm .netrc Product Sun StorageTek T3+/6X20 Controller Firmware 3.1 Sun StorageTek T3+ Array Controller FW 2.1 Sun StorageTek T3+ Array Sun StorageTek T3 Multi-Platform 1.1 Sun StorageTek T3 Array Sun StorageTek 6120 Array T3, t3.sh, firmware, fw, upgrade, ftp, interactive, login, Macro, definition Previously Published As 81841 Change History Date: 2005-10-11 User Name: 7058 Action: Approved Comment: Enabled STM for clarity. Updated review date. OK to republish. Version: 8 Date: 2005-10-11 User Name: 7058 Action: Accept Comment: Version: 0 Date: 2005-10-11 User Name: 37842 Action: Approved Comment: looks good. Version: 0 Product_uuid 62772b5a-05c6-11d8-84cb-080020a9ed93|Sun StorageTek T3+/6X20 Controller Firmware 3.1 231f0a60-146b-11d7-8cdc-f4071bf80989|Sun StorageTek T3+ Array Controller FW 2.1 2a714b10-0a18-11d6-86e2-d56b387d4fbf|Sun StorageTek T3+ Array bd277b78-24f2-11d7-98bd-a9b094d535c2|Sun StorageTek T3 Multi-Platform 1.1 2a6d7d50-0a18-11d6-8e0b-f0bd33b24928|Sun StorageTek T3 Array 2cd2e7d2-2980-11d7-9c3f-c506fe37b7ef|Sun StorageTek 6120 Array Attachments This solution has no attachment |
||||||||||||
|