Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1002189.1
Update Date:2009-01-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  1002189.1 :   Sun Fire[TM] and Netra[TM]: SC reported range error  


Related Items
  • Sun Fire V240 Server
  •  
  • Sun Fire V250 Server
  •  
  • Sun Fire V440 Server
  •  
  • Sun Fire V210 Server
  •  
  • Sun Netra 440 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>NEBS-Certified Servers
  •  
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
203099


Description
While upgrading Sun[TM] Advanced Lights Out Management (ALOM) software on Sun Fire[TM] or Netra[TM] systems, the error message "scadm: download failed, SC reported range error" may indicate a corrupt file.


Steps to Follow
Upgrading the ALOM on Sun Fire[TM] V210, V240, V250, V440, Netra[TM] 240 servers requires the use of two firmware files.
alombootfw

alommainfw

If either file is corrupt or if the boot option is used while upgrading alommainfw; the following error will occur.

scadm: download failed, SC reported range error

After issuing the scadm commands;
/usr/platform/`uname -i`/sbin/scadm download boot alombootfw
/usr/platform/`uname -i`/sbin/scadm download alommainfw

The following messages should be received after successfully completing each command.

/usr/platform/`uname -i`/sbin/scadm download boot alombootfw
.................... (100%)
Download completed successfully

Please wait for verification

...
Complete

/usr/platform/`uname -i`/sbin/scadm download alommainfw

.................... (100%)
Download completed successfully

Please wait for verification

...
Complete

If the correct command syntax has been used then the firmware should be retrieved again from www.sun.com/download -> select Downloads A-Z -> ALOM



Product
Sun Fire V210 Server
Sun Fire V440 Server
Sun Fire V240 Server
Sun Fire V250 Server
Netra 440 Server
Netra 240 Server

LOM, ALOM, SERIAL, MGT, password, tip, console, hardwire, sc, system, controller, v210, v240, v250, v440, 210, 240, 250, 440
Previously Published As
81641

Change History
Date: 2006-01-19
User Name: 7058
Action: Update Canceled
Comment: *** Restored Published Content *** SSH AUDIT
Version: 0
Date: 2006-01-19
User Name: 7058
Action: Update Started
Comment: SSH AUDIT
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback