Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1002176.1
Update Date:2009-08-03
Keywords:

Solution Type  Technical Instruction Sure

Solution  1002176.1 :   ARCHIVE - Updating BIOS/Firmware error on Sun Fire[TM] v20z/v40z error: Port out of range...please select a valid port( 49152 - 65535 )  


Related Items
  • Sun Fire V20z Server
  •  
  • Sun Fire V40z Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>x64 Servers
  •  

PreviouslyPublishedAs
203085


Description
This Read Me provides instructions on updating the BIOS and SP firmware for the Sun Fire[TM] V20z and Sun Fire[TM] V40z servers.
PDF: 819-2714-14 SP and BIOS Update ReadMe -  November 2006

Steps to Follow
This document contains instructions on how to update the BIOS and SP firmware in
the Sun Fire[TM] V20z and Sun Fire V40z servers.
Please note on page 11 (Page 14 in Acrobat Reader) and page 18 (Page 22 in Acrobat Reader) of the 819-2714-14.pdf that you should use port 50000 instead of port 1234:

Page 10:

Sun Fire V20z server:

java -jar /export/home/v20z/update_server/V2.2.0.6/updateServer.jar -f /export/home/v20z/sw_images/sp/spbase/V2.2.0.18/install.image -p 50000

Sun Fire V40z server:

java -jar /export/home/v40z/update_server/V2.2.0.6/updateServer.jar -f /export/home/v40z/sw_images/sp/spbase/V2.2.0.18/install.image -p 50000

sp update flash all -i <ip_address_solaris_machine> -p 50000

Page 18:

Sun Fire V20z server:

java -jar /export/home/v20z/update_server/V2.2.0.6/updateServer.jar -f /export/home/v20z/sw_images/sp/spbase/V2.2.0.18/install.image -p 50000
 

Sun Fire V40z server:

java -jar /export/home/v40z/update_server/V2.2.0.6/updateServer.jar -f /export/home/v40z/sw_images/sp/spbase/V2.2.0.18/install.image -p 50000

sp update flash all -i <ip_address_linux_machine> -p 50000

Using port 1234 will give this error message:

Error. Port out of range...please select a valid port (49152 - 65535).

Product
Sun Fire V20z Server
Sun Fire V40z Server

port, nsv, firmware, update, 2.2.0.18, NSV
Previously Published As
81421

Change History
Date: 2005-05-13
User Name: 7058
Action: Approved
Comment: Typo fixed.
OK to republish.
Version: 5
Date: 2005-05-10
User Name: 7058
Action: Accept
Comment:
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.