Solution Type Technical Instruction Sure Solution 1001960.1 : Sun StorEdge[TM] 9900: Setting Queue Depth Parameters on AIX
PreviouslyPublishedAs 202728 Description When attaching a 99x0 array to an IBM AIX server, queue depths need to be configured correctly. Below are 2 ways to configure this: via command-line and SMIT. According to the HDS knowledge article HDS17320, the following will apply if the AIX settings are not the same for each AIX host attached to the same port. SSB - D052 means incorrect AIX configuration The error paramchgnotify can potentially cause significant host performance degradation SSB error code D052 afcuaext paramchgnotify This is created when the port detects an AIX Host access to a LUN and the AIX Host has different AIX Characteristics Parameters than the last AIX Host access down this port. This situation arises when multiple AIX Hosts can access the same port (SAN Switched environment), but the Hosts have not been setup properly with identical AIX Characteristics Parameters. The AIX Characteristics Parameters are: 1. Q-Depth 2. Q-Type 3. R/W-TOV 4. Q-Err bit There is a fair amount of overhead in the routines associated with adapting from one set of Host parameters to another which can lead to significant Host Performance Degradation. After adding disks to an AIX server you should ensure that the QDEPTH, QTYPE and TIMEOUT value are correctly set. Please refer to the current server / storage configuration guide to find out the correct values and how to set them in the server. These values MUST be consistent per port and per volume group. Steps to Follow To change the device parameters using SMIT?: 1. Enter smit on the command line to start SMIT?. 2. On the SMIT? System Management panel, select Devices to bring up the Devices panel. 3. Select Fixed Disk to bring up the Fixed Disk panel. 4. Select Change/Show Characteristics of a Disk to bring up the Disk panel. 5. Select the desired device from the Disk menu to bring up the Change/Show Characteristics of a Disk panel. 6. Enter the desired queue depth, queue type [simple], and read/write time-out value [60]. Press Enter to complete the parameter changes. 7. Repeat steps 5 and 6 for each new device on the 9900V subsystem. 8. Verify that the parameters for all devices were successfully changed by entering the following command: #lsattr -E -1 hdiskx Example of SMIT: Change/Show Characteristics of a Disk Type or select values in entry fields. Press Enter AFTER making all desired changes. [MORE...4] Status Location Parent adapter Connection address Physical volume IDENTIFIER ASSIGN physical volume identifier no Queue DEPTH [8] Queuing TYPE [simple] Use QERR Bit [yes] Device CLEARS its Queue on Error [no] READ/WRITE time out value [60] START unit time out value [60] REASSIGN time out value [120] APPLY change to DATABASE only no F1=Help F2=Refresh F3=Cancel F4=List F5=Reset F6=Command F7=Edit F8=Image F9=Shell F10=Exit Enter=Do To change the device parameters from the AIX? command line: 1. To display the parameters for the specified device, at the AIX? command line prompt, enter: #lsattr -E -l hdiskx Note: hdiskx is the device file name, for example, hdisk2. #lsattr -E -1 hdisk1 scsi_id 0xef lun_id 0x0 location ww_name 0x500490e802757500 pvid 000432871c6bbceb0000000000000000 queue_depth 2 q_type simple q_err yes clr_q no rw_timeout 60 start_timeout 60 reassign_to 120 2. Change the device parameters by using: #chdev -l hdiskx -a rw_timeout= 60 -a q_type= simple -a queue_depth= x Note: x is used to indicate the desired queue depth 3. Repeat steps (1) and (2) for each new device on the 9900. 4. Verify that the parameters for all devices were successfully changed by entering the following command: #lsattr -E -1 hdiskx Product Sun StorageTek 9900V Series Array Sun StorageTek 9910 Sun StorageTek 9960 System Sun StorageTek 9970 System Sun StorageTek 9980 System Internal Comments Reference the 99x0 Configuration Guide for IBM AIX 9900, 9900V, 9910, 9960, 9970, 9980, 99x0, AIX, queue depth, throttle, max throttle, SMIT, lsattr Previously Published As 76927 Change History Date: 2007-10-01 User Name: 29589 Action: Approved Comment: Minor formatting changes. Does not appear that the changes Renee intended to make were ever done. This should be revisited post-migration to determine whether the update should be added. Version: 3 Date: 2007-10-01 User Name: 29589 Action: Accept Comment: Version: 0 Date: 2007-10-01 User Name: 124974 Action: Approved Comment: Done Version: 0 Product_uuid f55c65ae-16a0-11d7-82ad-99701a4c6e31|Sun StorageTek 9900V Series Array 2a918ae2-0a18-11d6-834a-c679537eebe7|Sun StorageTek 9910 2a94fb3c-0a18-11d6-90a8-c9c08656284f|Sun StorageTek 9960 System 4ea4b951-9fc9-4f1f-b64e-69572a400fb4|Sun StorageTek 9970 System c2428fbe-8ab7-41d0-8b6e-ab489823c9d4|Sun StorageTek 9980 System Attachments This solution has no attachment |
||||||||||||
|