Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1001589.1
Update Date:2009-09-22
Keywords:

Solution Type  Technical Instruction Sure

Solution  1001589.1 :   PGX Framebuffer  


Related Items
  • Sun Ultra 5 Workstation
  •  
  • Sun Ultra 10 Workstation
  •  
Related Categories
  • GCS>Sun Microsystems>Desktops>Workstations
  •  

PreviouslyPublishedAs
202169


Steps to Follow
The PGX framebuffer card is an 8-bit, PCI-based, 2-D acceleration graphics
card that supports the following resolutions:
- 1600 x 1000, 76 Hz refresh rate, single buffered
		  66 Hz
- 1440 x  900, 76 Hz refresh rate, single buffered
- 1280 x  800, 76 Hz refresh rate, single buffered
		  75 Hz
		  67 Hz
		  60 Hz
- 1152 x  900, 76 Hz refresh rate
		  66 Hz
- 1024 x  768, 75 Hz refresh rate
		  70 Hz
		  60 Hz
-  800 x  600, 75 Hz refresh rate
-  768 x  575, 50 Hz refresh rate
-  640 x  480, 60 Hz refresh rate
In order to change the resolution, you need to issue the m64config command.
For most installations, the M64 Frame Buffer card will automatically configure
itself to the proper screen resolution and refresh rate for your monitor.
However, if a non-Sun monitor is connected to the M64 Frame Buffer, the monitor
may come up in the wrong screen resolution.
To see which resolutions are supported on your system for the card, issue the
command
	/usr/sbin/m64config -res \?
If the command cannot be found on the system, make sure that SUNWm64cf is
installed.
When installed, the PGX framebuffer will show up as /dev/m640.
The card is not supported on the Ultra1[TM] and Ultra2[TM] or any other SuperSPARC(R)
based systems.  It'll work on any PCI equipped Sun system and is standard
on the Ultra 5 and Ultra 10 motherboards.


Product
Ultra 5 Workstation
Ultra 10 Workstation

Previously Published As
16609

Change History
Date: 2006-07-03
User Name: 95826
Action: Update Canceled
Comment: *** Restored Published Content *** canceling update as per updater s agreement
Version: 0
Date: 2006-07-03
User Name: 95826
Action: Reassign
Comment: reassigning document as per updater s agreement
Version: 0
Date: 2004-02-12
User Name: 92422
Action: Updated
Comment:
Version: 0
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : Daniel Nault
comment : reworking document
date : Mar 12, 2003



updated by : John Knudsen
comment : admin cleanup, ok, tm
date : Jun 28, 2002



updated by : Thom Chumley
comment : No comment
date : Mar 2, 1998
Version: 0
Product_uuid
29f1cd04-0a18-11d6-9b05-e83e08f6e600|Ultra 5 Workstation
29f5233c-0a18-11d6-99d6-d97e56fb5daf|Ultra 10 Workstation

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.