Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1151715.1 : Running the 'setnetwork' or 'setupplatform' Command on Sun SPARC Enterprise Mx000 Servers with XCP 1092 Firmware Fails with Error Message
In this Document
Applies to:Sun SPARC Enterprise M3000 Server - Version: Not ApplicableSun SPARC Enterprise M4000 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun SPARC Enterprise M5000 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun SPARC Enterprise M8000 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun SPARC Enterprise M9000-32 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun SPARC Sun OS _________________ _________________ Date of Workaround release: 16-Jul-2010 _________________________________ Date of Resolved Release: 03-Aug-2010 DescriptionOn Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 servers with XCP 1092 firmware, the 'setnetwork' or 'setupplatform' commands may fail with: "An internal error has occurred", and will not configure the XSCFU external network interfaces. ('setnetwork' and 'setupplatform' are XSCF commands).Note: The XSCF firmware is a single centralized point for the management of hardware configuration, control of hardware monitoring, cooling system (fan units), domain status monitoring, power on and power off of peripheral devices, and error monitoring. Please see the "Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide" at http://docs.sun.com/app/docs/coll/m4000-sw for more information.
Likelihood of OccurrenceThis issue can occur on the following platforms:SPARC Platform
XCP 1092 output will appear similar to the following:XSCF> version -c xcp XSCF#0 (Active ) Possible SymptomsWhen running either of the following commands:orXSCF> setnetwork xscf#0-lan#0 -m 255.255.255.0 10.210.17.130 The following error will be returned:XSCF> setupplatform An internal error has occurred. Please contact your system administrator. Workaround or ResolutionTo work around this issue, configure the Domain to Service Processor Communications Protocol (DSCP) network before running 'setnetwork', as in the following example:XSCF> setdscp -i 192.168.224.0 -m 255.255.255.0 This issue is addressed in the following releases: SPARC Platform XCP 1093 Firmware for M3000 through M9000 Servers can be downloaded from the following site: http://www.oracle.com/technetwork/server-storage/sun-sparc-enterprise/downloads/index.html PatchesModification History16-Jul-2010: Date of Workaround release:03-Aug-2010: Date of Resolved release - XCP 1093 Firmware release, issue is Resolved This issue is a regression caused by the putback for CR 6861630. Responsible Engineer: [email protected] Please send technical questions to the following: [email protected] and copy the Responsible Engineer Oracle knowledge analyst: [email protected] References<SUNBUG:6952185>Attachments This solution has no attachment |
|||||||||||||||||||||
|