Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1019814.1 : An IP(7P) Spoofing Security Vulnerability in Mid-range Sun Fire Server's Firmware May Allow Unauthorized Access to System Controllers
PreviouslyPublishedAs 246746 Bug Id <SUNBUG: 6707931> Date of Resolved Release 12-Dec-2008 An IP(7P) spoofing security vulnerability in certain midrange Sun Fire Server's firmware: 1. Impact An IP(7P) spoofing security vulnerability in certain Mid-range Sun Fire Server's firmware may allow a remote privileged/unprivileged user to gain unauthorized access to the System Controller (SC). Such users may also gain access to the system console and possibly the host operating system running on these servers.This may allow such users to power off or reset the system which is a type of Denial of Service (DoS). 2. Contributing Factors This issue can occur in the following releases: SPARC Platform
To determine the version of ScApp on a system, the following command can be run (from sc0:SC>): sc0:SC> showscNote: This issue only impacts systems that have a System Controller V2 without SSH enabled. To determine if a system has System Controller V2, the following command can be run (from the platform shell): sc0:SC> showscTo determine if SSH is configured on the System Controller, please see the documentation regarding configuring of network parameters in the System Administration Guide for these servers. 3. Symptoms There are no reliable symptoms that would indicate the described issues have been exploited. 4. Workaround To work around the described issue, one of the following options can be used:
5. Resolution This issue is addressed in the following releases: SPARC Platform
Product Sun Fire 3800 Server Sun Fire 4800 Server Sun Fire 4810 Server Sun Fire 6800 Server Sun Fire E2900 Server Sun Fire E4900 Server Sun Fire E6900 Server Sun Fire V1280 Server Netra 1280 Server Sun Netra 1290 Server References<SUNPATCH: 114527-12>Internal Comments Please send technical questions to the following email: [email protected] and CC the following persons: Internal Contributor/Submitter Internal Eng Responsible Engineer Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group SSG ES (Enterprise Systems) Internal Resolution Patches 114527-12 Internal Sun Alert & FAB Admin Info ReferencesSUNPATCH:114527-12ReferencesSUNPATCH:114527-12ReferencesSUNPATCH:114527-12Attachments This solution has no attachment |
||||||||||||
|