Solution Type Sun Alert Sure Solution 1019715.1 : Restart of VTL Services May be Required After Daylight Saving Time (DST) Change
PreviouslyPublishedAs 244446 Bug Id <SUNBUG: 6763139> Product Sun StorageTek Virtual Tape Library Plus Storage Appliance 1.0 Sun StorageTek Virtual Tape Library Plus Storage Appliance 2.0 Date of Workaround Release 27-Oct-2008 Date of Resolved Release 27-Oct-2008 Restart of VTL Services May be Required After Daylight Saving Time (DST) Change 1. Impact Any Sun StorageTek Virtual Tape Library (VTL) system that has “time based” policies configured (i.e., Automated Tape Caching, Replication) will need to restart the VTL services after the time change for Daylight Saving Time (DST). Failure to restart VTL services may cause the schedule for the time based VTL jobs to be off one hour after the time change, until the next restart of VTL services. 2. Contributing Factors This issue can occur on the following platforms:
3. Symptoms After the server time changes, the VTL time based policy scheduled jobs (i.e., ATC migration jobs) may happen plus/minus the difference from the actual time. The schedule for the time based VTL jobs will be off until the next restart of VTL services. 4. Workaround To work around this issue, stop/suspend backup/migration jobs and restart VTL services. VTL services can be restarted via VTL Console (right click server name -> System Maintenance -> Restart VTL) or from a command line: # vtl restart Notes: 1. For HA configurations, either first initiate manual failover of one node prior to restarting VTL services (then repeat for other node), OR suspend failover on both nodes, then restart VTL services on both nodes and resume failover on both nodes when done. 2. Backup jobs directed at VTL are handled by the Backup Application/Server and do not require VTL restart. If no time based policies are configured in VTL the restart of VTL is not necessary. 5. Resolution Please see the Work Around section above. Modification History 11-Aug-2010: No further updates. Republished Resolved. Internal Comments Please send technical questions to the following email: [email protected] and CC the following persons: Internal Eng Responsible Engineer Internal Services Knowledge Engineer VTL patch is targeted for 1QCY2009, so that the restart of VTL services will not be needed for server time changes. Internal Contributor/submitter [email protected] Internal Services Knowledge Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Sun Alert & FAB Admin Info 24-Oct-2008, david m: Originally drafted as FAB, now SA - Completed draft and sent to Review 27-Oct-2008, david m: review completed, send to publish Attachments This solution has no attachment |
||||||||||||
|