Solution Type Sun Alert Sure Solution 1019470.1 : Security Vulnerability in Firmware for T5220, T5140 and T5240 Systems May Allow a Denial of Service (DoS)
PreviouslyPublishedAs 239930 Bug Id <SUNBUG: 6710098> Product Sun Netra T5220 Server Sun SPARC Enterprise T5140 Server Sun SPARC Enterprise T5240 Server Date of Resolved Release 05-Aug-2008 Security Vulnerability in Firmware for T5220, T5140 and T5240 Systems May Allow a Denial of Service (DoS) 1. Impact A security vulnerability in the firmware for Sun Netra T5220 systems and SPARC Enterprise T5140 and T5240 systems may allow a local unprivileged user to panic the system, which is a type of Denial of Service (DoS). 2. Contributing Factors This issue can occur on the following platforms: SPARC Platform
To determine the firmware version on the system, log in to the service processor and run the 'showhost' command as in the following example (from the T5220): sc> showhost 3. Symptoms The system will panic or produce unpredictable results. The panic string will include "BAD TRAP type=33" or "BAD TRAP type=34". User applications may fail with a segmentation fault (SIGSEGV) and may also write a core file, depending on the user's privileges and the system-wide coreadm(1M) settings. 4. Workaround There is no workaround for this issue. Please see the Resolution section below. 5. Resolution This issue is addressed on the following platforms: SPARC Platform
Modification History 28-Aug-2008: Updated Products, Impact, Contributing Factors and Resoluton sections References<SUNPATCH: 136934-03><SUNPATCH: 136936-06> Internal Comments Please send technical questions to the following email: [email protected] and CC the following persons: Internal Contributor/Submitter Internal Eng Responsible Engineer Internal Services Knowledge Engineer NOTE CP3260 is not affected by this issue even though there is a patch for CP3260 which lists this bug. Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group SSG NSN (Netra Systems and Networking) Internal Resolution Patches 136934-03, 136936-06 Internal Sun Alert & FAB Admin Info 24-Jul-2008, david m: draft created, send for 24hr Security review, hold for patch release 05-Aug-2008, david m: patch released, signoff OK, send to publish ReferencesSUNPATCH:136934-03SUNPATCH:136936-06 Attachments This solution has no attachment |
||||||||||||
|