Solution  1019447.1 :   RAID 10 Migration with Sun StorageTek SAS RAID HBA may cause Data Integrity Issues  


Related Items
  • Sun Storage 3Gb SAS RAID HBA, Internal
  •  
  • Sun Storage 3Gb SAS RAID HBA, External
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Data Loss
  •  

PreviouslyPublishedAs
239766


Bug Id
<SUNBUG: 6720939>

Product
Sun StorageTek 3 Gb SAS RAID HBA, External
Sun StorageTek 3 Gb SAS RAID HBA, Internal

Date of Workaround Release
15-Jul-2008

Date of Resolved Release
05-Aug-2008

RAID 10 Migration with Sun StorageTek SAS RAID HBA may cause Data Integrity Issues

1. Impact

Attempting any RAID level migration to or from RAID 10 systems with Sun StorageTek SAS RAID HBAs (with firmware revision 15595 through 15816) may halt the RAID card and could result in loss of the logical drive and may cause data integrity issues.

2. Contributing Factors

This issue can occur on the following platform:

  • Sun StorageTek SAS RAID HBA with firmware versions 15595 through 15816

Notes:

  1. This issue only affects Sun StorageTek SAS RAID HBA 375-3536 with firmware versions 15595 through 15816.
  2. This issue only occurs when attempting a migration procedure to change the RAID level of an existing RAID set, either to or from RAID 10. If this procedure is not being initiated, this issue will not be present.
To determine the current firmware revision level, the following command can be run:

$ arcconf getversion

3. Symptoms

The system may experience immediate command failure, with possible loss of logical drive and loss of data integrity.

4. Workaround

To prevent this issue from occuring until the firmware can be updated, avoid the migration of an existing RAID set to or from RAID 10.

5. Resolution

This issue is addressed on the following platform:

  • Sun StorageTek SAS RAID HBA with firmware versions 15825 or later
which can be downloaded from the following site:
http://support.intel.com/support/go/sunraid.htm


This Sun Alert notification is being provided to you on an "AS IS" basis. This Sun Alert notification may contain information provided by third parties. The issues described in this Sun Alert notification may or may not impact your system(s). Sun makes no representations, warranties, or guarantees as to the information contained herein. ANY AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This Sun Alert notification contains Sun proprietary and confidential information. It is being provided to you pursuant to the provisions of your agreement to purchase services from Sun, or, if you do not have such an agreement, the Sun.com Terms of Use. This Sun Alert notification may only be used for the purposes contemplated by these agreements.

Copyright 2000-2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A. All rights reserved.


Modification History
05-Aug-2008: Updated Contributing Factors and Resolution sections; now Resolved


Internal Comments
Please send technical questions to the following email:
[email protected]
and CC the following persons:
Internal Contributor/Submitter
Internal Eng Responsible Engineer
Internal Services Knowledge Engineer


Firmware build 15825 will resolve this issue for both Internal/External
versions of the Sun StorageTek SAS RAID HBA, and will be available on
Intel's website Mid-to-End of July 08.
Internal Contributor/submitter
[email protected]

Internal Eng Responsible Engineer
[email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Eng Business Unit Group
NWS (Network Storage)

Internal Sun Alert & FAB Admin Info
14-Jul-2008, david m: draft created, send for 24hr review, next update ETA week of Jul 21 for FW update release 15825
15-Jul-2008, david m: review completed, send to publish
05-Aug-2008, david m: FW released, republish Resolved


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback