Solution Type Sun Alert Sure Solution 1019313.1 : For Sun StorageTek 5210, 5310, 5220, and 5320 NAS Appliances with NAS OS 4.22, NAS Clients May Experience Intermittent I/O Issues
PreviouslyPublishedAs 238410 Bug Id <SUNBUG: 6697883> Product Sun StorageTek 5210 NAS Appliance Sun StorageTek 5220 NAS Appliance Sun StorageTek 5310 NAS Appliance Sun StorageTek 5320 NAS Appliance Date of Preliminary Release 02-Jun-2008 Date of Resolved Release 23-Oct-2008 For Sun StorageTek 5210, 5310, 5220, and 5320 NAS Appliances with NAS OS 4.22, NAS Clients May Experience Intermittent I/O Issues 1. Impact For Sun StorageTek 5210, 5310, 5220, and 5320 NAS Appliances with NAS OS 4.22(M0), NAS NFS/CIFS clients may experience intermittent I/O errors during certain operations. This may cause applications to unexpectedly fail or exit. 2. Contributing Factors This issue can occur on the following platforms:
Notes:
To determine if a system is affected, issue the "version" cli command. The output will be similar to one of the following: NAS> version 3. Symptoms Clients may receive spurious I/O errors (EOI). One or more messages similar to the following may appear in the NAS Appliance system log: 05/05/08 18:09:13 E /d: too many xa_n_op, shrink failed, n_op These messages can be viewed using the "logtail" CLI or via the NAS OS Web Admin: View System Events -> Display
System Log
4. Workaround There is no workaround for this issue. Please see the Resolution section below. 5. Resolution This issue is addressed in the following release:
This Sun Alert
notification is being provided to you on
an "AS IS"
basis. This Sun Alert notification may contain information provided by
third parties. The issues described in this Sun Alert notification may
or may not impact your system(s). Sun makes no representations,
warranties, or guarantees as to the information contained herein. ANY
AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR
NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU
ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT,
INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT
OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This
Sun Alert notification contains Sun proprietary and confidential
information. It is being provided to you pursuant to the provisions of
your agreement to purchase services from Sun, or, if you do not have
such an agreement, the Sun.com Terms of Use. This Sun Alert
notification may only be used for the purposes contemplated by these
agreements.
Modification History 23-Oct-2008: Updated Contributing Factors and Resolution sections, now Resolved References<SUNPATCH: 119352-11>Internal Comments Please send technical questions to the following email: [email protected] and CC the following persons: Internal Contributor/Submitter Internal Eng Responsible Engineer Internal Services Knowledge Engineer Expected to be fixed in 4.22M1 (not yet released) An IDR, 4.22M0IDR7R5, is in the works. Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Resolution Patches 119352-11 Internal Escalation ID 1-23929107, 70257876, 1-23847450, 1-23787239, 1-23799862, 1-2379065 Internal Sun Alert & FAB Admin Info 30-May-2008, david m: draft created, send for review 02-Jun-2008, david m: review completed, send to publish 23-Oct-2008, david m: received update from submitter, patch released, issue resolved ReferencesSUNPATCH:119352-11Attachments This solution has no attachment |
||||||||||||
|