Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1019253.1 : Expansion of Snapshot Repository on Sun StorageTek 6140 and 6540 Arrays May Freeze and Result in Write Cache Becoming Disabled
PreviouslyPublishedAs 237744 Bug Id <SUNBUG: 6697651> Product Sun StorageTek 6140 Array Sun StorageTek 6540 Array Date of Workaround Release 14-May-2008 Date of Resolved Release 05-May-2009 Expansion of Snapshot Repository on Sun StorageTek 6140 and 6540 Arrays May Freeze and Result in Write Cache Becoming Disabled 1. Impact For Sun StorageTek 6140 and 6540 arrays with firmware 07.10.25.10, an expansion of a snapshot repository may freeze and result in write cache becoming disabled. As a consequence of this Bug, it may be necessary to wipe the array configuration and recreate it. 2. Contributing Factors This issue can occur on the following platforms:
# /opt/SUNWsesscs/cli/bin/sscs list array <array_name> 3. Symptoms When attempting to expand a snapshot volume, the expansion never completes and performance drops due to the cache becoming disabled. Note: A SupportData collection for the array must be obtained in order to confirm this issue. 4. Workaround To avoid this issue, do not expand a snapshot repository if the array has firmware 07.10.25.10. If a snapshot repository expansion is performed and this issue is encountered, it will be necessary to contact Sun Support Services for the proper recovery procedure. 5. Resolution This issue is addressed on the following platforms:
This Sun Alert
notification is being provided to you on
an "AS IS"
basis. This Sun Alert notification may contain information provided by
third parties. The issues described in this Sun Alert notification may
or may not impact your system(s). Sun makes no representations,
warranties, or guarantees as to the information contained herein. ANY
AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR
NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU
ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT,
INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT
OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This
Sun Alert notification contains Sun proprietary and confidential
information. It is being provided to you pursuant to the provisions of
your agreement to purchase services from Sun, or, if you do not have
such an agreement, the Sun.com Terms of Use. This Sun Alert
notification may only be used for the purposes contemplated by these
agreements.
Modification History 05-May-2009: Updated Resolution section; issue Resolved 29-Sep-2009: Updated Impact section Internal Comments Please send technical questions to the following email: [email protected] and CC the following persons: Internal Contributor/Submitter Internal Eng Responsible Engineer Internal Services Knowledge Engineer Field and Solution Center Engineers are required to open an escalation with TSC Storage Backline (former PTS Storage) for the proper corrective action and reference this Sun Alert. Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Sun Alert & FAB Admin Info 13-May-2008, david m: draft created, send for review 14-May-2008, david m: review completed, send to publish 05-May-2009, david m: CAM 6.4 released, update Resolution, republish resolved 29-Sep-2009, david m: update Impact section Attachments This solution has no attachment |
||||||||||||
|