Solution Type  Sun Alert Sure

Solution  1019253.1 :   Expansion of Snapshot Repository on Sun StorageTek 6140 and 6540 Arrays May Freeze and Result in Write Cache Becoming Disabled  


Related Items
  • Sun Storage 6540 Array
  •  
  • Sun Storage 6140 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
237744


Bug Id
<SUNBUG: 6697651>

Product
Sun StorageTek 6140 Array
Sun StorageTek 6540 Array

Date of Workaround Release
14-May-2008

Date of Resolved Release
05-May-2009

Expansion of Snapshot Repository on Sun StorageTek 6140 and 6540 Arrays May Freeze and Result in Write Cache Becoming Disabled

1. Impact

For Sun StorageTek 6140 and 6540 arrays with firmware 07.10.25.10, an expansion of a snapshot repository may freeze and result in write cache becoming disabled. As a consequence of this Bug, it may be necessary to wipe the array configuration and recreate it.

2. Contributing Factors

This issue can occur on the following platforms:
  • Sun StorageTek 6140 Array with firmware 07.10.25.10
  • Sun StorageTek 6540 Array with firmware 07.10.25.10
The current firmware version can be determined by using the CAM GUI or by using the the 'sscs' CLI, as in the following example:
# /opt/SUNWsesscs/cli/bin/sscs list array <array_name>
Array: <array_name>
Array Type:          6140
Serial Number:       xxxxxxxxxxxxxxx
Firmware Version:    07.10.25.10
[...]

3. Symptoms

When attempting to expand a snapshot volume, the expansion never completes and performance drops due to the cache becoming disabled.

Note: A SupportData collection for the array must be obtained in order to confirm this issue.

4. Workaround

To avoid this issue, do not expand a snapshot repository if the array has firmware 07.10.25.10.

If a snapshot repository expansion is performed and this issue is encountered, it will be necessary to contact Sun Support Services for the proper recovery procedure.

5. Resolution

This issue is addressed on the following platforms:
  • Sun StorageTek 6140/6540 Arrays with firmware 07.50.08.10 or later (as bundled with CAM release 6.4.0)
CAM 6.4.0 can be downloaded from the Sun Download Center at the StorageTek Common Array Manager URL.

This Sun Alert notification is being provided to you on an "AS IS" basis. This Sun Alert notification may contain information provided by third parties. The issues described in this Sun Alert notification may or may not impact your system(s). Sun makes no representations, warranties, or guarantees as to the information contained herein. ANY AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This Sun Alert notification contains Sun proprietary and confidential information. It is being provided to you pursuant to the provisions of your agreement to purchase services from Sun, or, if you do not have such an agreement, the Sun.com Terms of Use. This Sun Alert notification may only be used for the purposes contemplated by these agreements.

Copyright 2000-2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A. All rights reserved.


Modification History
05-May-2009: Updated Resolution section; issue Resolved
29-Sep-2009: Updated Impact section


Internal Comments
Please send technical questions to the following email:
[email protected]
and CC the following persons:
Internal Contributor/Submitter
Internal Eng Responsible Engineer
Internal Services Knowledge Engineer

Field and Solution Center Engineers are required to open an escalation
with TSC Storage Backline (former PTS Storage) for the proper
corrective action and reference this Sun Alert.


Internal Contributor/submitter
[email protected]

Internal Eng Responsible Engineer
[email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Eng Business Unit Group
NWS (Network Storage)

Internal Sun Alert & FAB Admin Info
13-May-2008, david m: draft created, send for review
14-May-2008, david m: review completed, send to publish
05-May-2009, david m: CAM 6.4 released, update Resolution, republish resolved
29-Sep-2009, david m: update Impact section


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback