Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1019006.1 : Collecting Support Data Using Common Array Manager while Drives are Bypassed May Cause Controllers to Reboot
PreviouslyPublishedAs 231802 Bug Id <SUNBUG: 6649629> Product Sun StorageTek 6130 Array Sun StorageTek 6140 Array Sun StorageTek 6540 Array Sun StorageTek Flexline 240 Array Sun StorageTek Flexline 280 Array Sun StorageTek Flexline 380 Array Sun StorageTek Common Array Manager Software 6.0 Date of Workaround Release 15-Feb-2008 Date of Resolved Release 04-Mar-2008 Collecting Support Data Using Common Array Manager While Drives are Bypassed May Cause Controllers to Reboot 1. ImpactSun StorageTek 6130, 6140, and 6540 (with firmware 06.19.25.16) and Flexline 240, 280, and 380 arrays (with firmware 06.19.25.26) and collecting support data using Common Array Manager (CAM) 6.0 while drives are bypassed may cause controllers to reboot without warning. This may cause device path failovers or a loss of access due to both primary and secondary paths to a device being inaccessible.2. Contributing FactorsThis issue can occur on the following platforms:
3. SymptomsAt minimum, systems will experience device path fail-overs. At worst, there will be a loss of access due to both primary and secondary paths to a device being inaccessible.This issue can only occur during array support data collection (see Contributing Factors). The system must also have at least one drive in a "Bypassed" state. This condition can be reviewed by looking at the following: Browser: CAM->Array_Name->Physical
Devices->Disks
SSCS: sscs list -a <array> disk
Host message events showing SCSI or Fibre Channel messages indicating loss of access to one or both array controllers are the most common symptom associated with this issue. Hosts can also log path failovers as one or both controllers go through the boot cycle. CAM may throw an error during collection, similar to the following: Exception while accessing hids,108 on Controller A:This can be found during the collection using the Service Advisor, or by reviewing the "stateCaptureData.dmp" file included in the support data collection. 4. WorkaroundThis issue can be avoided by not collecting support data when you know that a drive has been removed or bypassed by the storage subsystem. For this case, you can collect the data using the "service" command.The following CLI commands can be run to obtain support data for CAM: service -d <array_name> -c print -t arrayprofile > arrayProfileSummary.txt service -d <array_name> -c print -t mel > majorEventLog.txt service -d <array_name> -c read -q nvsram region=0xEE > NVSRAMdata.txt service -d <array_name> -c print -t rls > readLinkStatus.csv sscs list alarm > alarms.txt 5. ResolutionThis issue is addressed in the following release:
CAM 6.0.1 is available for download at: https://cds.sun.com/is-bin/INTERSHOP.enfinity/WFS/CDS-CDS_SMI-Site/en_US/-/USD/ViewProductDetail-Start?ProductRef=SSTKCAM-6.0.1.11-OTH-G-F@CDS-CDS_SMI This Sun Alert notification is being provided to you on an "AS IS" basis. This Sun Alert notification may contain information provided by third parties. The issues described in this Sun Alert notification may or may not impact your system(s). Sun makes no representations, warranties, or guarantees as to the information contained herein. ANY AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This Sun Alert notification contains Sun proprietary and confidential information. It is being provided to you pursuant to the provisions of your agreement to purchase services from Sun, or, if you do not have such an agreement, the Sun.com Terms of Use. This Sun Alert notification may only be used for the purposes contemplated by these agreements. Copyright 2000-2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A. All rights reserved. Modification History 04-Mar-2008: Updated Resolution section, RESOLVED 26-mar-2008: Updated Workaround section 10-Jul-2008: Updated Workaround for clarification Internal Comments Please send technical questions to the following email: [email protected] and CC the following persons: Internal Contributor/Submitter Internal Eng Responsible Engineer Internal Services Knowledge Engineer Pending release on the SDLC, CAM 6.0.1.11 will have the "hids 108" command removed from the support data collection. Avoid running 'hids' altogether during serial sessions, especially when any drive is in a non-optimal state. The excLogShow will show: ---- Log Entry #29 JAN-11-2008 09:13:02
AM ---- Exception: Data Abort cpsr: a0000013 pc: 0x01348d50 toString__CQ23hid2LUi + 0x5a4 Alignment Fault fsr: f3 far: e7fddf0a biusr: 10000059 bear: ffffe1ac Registers: r0 = 0 r1 = 9 r2 = a280244 r3 = e7fddefe r4 = 0 r5 = a280244 r6 = 9a28a00 r7 = a35c7d8 r8 = 5 r9 = a35c7d8 r10 = a28022c r11/fp = a280498 r12/ip = a280154 r13/sp = a280154 r14/lr = 1348d28 pc = 1348d50 cpsr = a0000013 Stack Trace: ======== STACK SHOW ======== Showing for task id = 0xa280840 (symTask2), Running FP=0xa280498, SP=0xa280154, PC=0x1348d50 Current executing task id = 0xa280840 (symTask2); not interrupted Frame Ptr Ret Addr Return Name + Offset Called Name + Offset ========== ========== ================================ ======================== 0x0a2807f0 0x00139bc8 vxTaskEntry + 0x2c vkiTask 0x0a28078c 0x0005d824 vkiTask + 0xd4 srcOpTask 0x0a280748 0x012f29c0 srcOpTask + 0x120 cmdProcess 0x0a280730 0x014e5dbc cmdProcess + 0x74 symSYMbolCommandHandler 0x0a2806e0 0x016caa8c symSYMbolCommandHandler + 0x54 svciov_dispatch 0x0a280630 0x016dc3b4 svciov_dispatch + 0x3ec stateCapture_1 0x0a280610 0x016c8ac8 stateCapture_1 + 0x38 systemStateCapture 0x0a280530 0x0171e8c0 systemStateCapture + 0x5a0 hids 0x0a280510 0x01355f44 hids + 0x4c show__Q23hid10HidManagerUlUlUl 0x0a2804e8 0x01356048 show__Q23hid10HidManagerUlUlUl + 0x90 showFunc__Q23hid10HidManagerP9HIDS_INFO 0x0a2804d0 0x013530e4 showFunc__Q23hid10HidManagerP9HIDS_INFO + 0x2ac traverseSingleList__Q23hid10HidManagerP9HIDS_INFO 0x0a2804a8 0x013539b8 traverseSingleList__Q23hid10HidManagerP9HIDS_INFO + 0xe4 show__CQ23utl14ShowableObjecti 0x0a28048c 0x0182e138 show__CQ23utl14ShowableObjecti + 0xcc toString__CQ23hid2LUi 0x01348d50 toString__CQ23hid2LUi + 0x5a4 ******** Task Id: 0xa280840 Name: "symTask2" Status: 0x00 (ready) Options: 0x0004 (dealloc_stk) Priority: 125 Stack base: 0xa280840 Stack end: 0xa27cea4 (adjusted for name) Stack size: 0x399c (14748) Stack margin: 0x1708 (5896) Stack limit: 0xa27ceb0 Pend queue: 0x98c1b10 Last errno: 0x1c0001 Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected], [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Escalation ID 1-23211257 Internal Sun Alert & FAB Admin Info WF 15-Feb-2008, david m: send for release WF 14-Feb-2008, david m: draft created Attachments This solution has no attachment |
||||||||||||
|