Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1017360.1
Update Date:2011-02-25
Keywords:

Solution Type  Sun Alert Sure

Solution  1017360.1 :   On Sun Ultra 25/45, Upgrading OBP May Cause POST to Hang or OBP to Generate a RED STATE Exception Error  


Related Items
  • Sun Ultra 45 Workstation
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
228425


Product
Sun Ultra 45 Workstation

Bug Id
<SUNBUG: 6474536>

Date of Resolved Release
12-DEC-2006

Impact

With OBP parameter settings "diag-switch?=true" and "diag-level=max" set, upgrading the OBP (Standalone Flash Update) on Sun Ultra 25 or Sun Ultra 45 systems may cause POST to hang or OBP to generate a "RED STATE Exception" error. The system may also become unbootable.


Contributing Factors

This issue can occur on the following platforms:

  • Sun Ultra 25 with patch 121687-01 and without patch 121687-02
  • Sun Ultra 45 with patch 121686-01 and without patch 121686-02

Note: The issue is not with the OBP binaries within these patches. The issue is caused by a bug in the Standalone Flash update "Makefile," which builds the combined Standalone Flash-Update image integrating the OBP, POST and obdiag binaries. POST is not able to run because it is not properly configured in the PROM space.


Symptoms

Should the described issue occur, POST will hang or the system may generate a RED STATE Exception error. The system may become unbootable.


Workaround

Prior to running the standalone flash update utility, set the OBP parameters "diag-switch?=false" and "diag-trigger=none". After running the standalone flash update utility, POST will not run and OBP will boot normally.


Resolution

This issue is addressed on the following platforms:

  • Sun Ultra 25 with patch 121687-02 or later
  • Sun Ultra 45 with patch 121686-02 or later


References

<SUNPATCH: 121687-02>
<SUNPATCH: 121686-02>

Previously Published As
102750
Internal Comments


This regression was caused by the putback for CR6474536.



(Ultra 25 will be added to the "Product" Field as soon as it is added to the database).


Internal Contributor/submitter
[email protected]

Internal Eng Business Unit Group
SSG WGS (Workgroup Systems)

Internal Eng Responsible Engineer
[email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Resolution Patches
121687-02, 121686-02

Internal Sun Alert Kasp Legacy ID
102750

Internal Sun Alert & FAB Admin Info
Critical Category: Availability ==> Regression
Significant Change Date: 2006-12-12
Avoidance: Patch
Responsible Manager: [email protected]
Original Admin Info: [WF 12-Dec-2006, dave m: review ok, send for release]
[WF 11-Dec-2006, dave m: draft created, send for review]

Product_uuid
ef0ed4f2-685b-11da-b8a0-080020a9ed93|Sun Ultra 45 Workstation

References

SUNPATCH:121686-02
SUNPATCH:121687-02

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback