Solution Type Sun Alert Sure Solution 1017351.1 : Sun StorEdge 6920 DSP Firmware May Cause Data Avaiability Issue
PreviouslyPublishedAs 228410 Product Sun StorageTek 6920 System Bug Id <SUNBUG: 6451084> Date of Resolved Release 22-NOV-2006 Impact On the Sun StorEdge 6920 with Data Services Platform (DSP) firmware 2.2.1.182 installed, "Persistent Reservation" issues may cause DSP panics which could result in storage being unavailable. Contributing Factors This issue can occur on the following platform:
The following conditions must be present for this issue to occur:
Note: The above factors are not readily visible. Symptoms The DSP will panic with the following string: PANIC!!: file - isp_target.c line - 5148 MED_FREE_BUF - free pr/resv cmd when not finished, xsp = 0xXXXXXXXX Panic strings first show up on the console and then are recorded in the messages file (and in a core dump, if active). Workaround There is no workaround for this issue. Please see the Resolution section below. Resolution This issue is addressed on the following platform:
References<SUNPATCH: 118396-52>Previously Published As 102727 Internal Comments * "Command" referred to in Contributing Factors is to internal scsi commands, not something that is actively or overtly done by a user (ie: commands that can be found in scsi protocol). Examples would be Read/Write/Open/Close etc. The problem is only with UBR19 & UBR20. There was new functionality that was added in 19 (and migrated to 20 before it was caught) that caused the problem. The level of DSP code would be 02.02.01.182 is where the problem is. It's fixed in 02.02.01.189. See PTS website for details: http://pts-storage.west/products/SE6920/baseline_matrix.html Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-18423401, 1-18702805, 1-19457830 Internal Resolution Patches 118396-52 Internal Sun Alert Kasp Legacy ID 102727 Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Regression Significant Change Date: 2006-11-22 Avoidance: Upgrade Responsible Manager: [email protected] Original Admin Info: [WF 22-Nov-2006, dave m: review completed, send for release] [WF 20-Nov-2006, dave m: draft created, questions for eng] Product_uuid 67794720-356d-11d7-8ef2-ce2ac2bc9136|Sun StorageTek 6920 System ReferencesSUNPATCH:118396-52Attachments This solution has no attachment |
||||||||||||
|