Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1001259.1 : Sun StorEdge 3510 Fiber Channel Array May Lose In-band Connectivity After Generating an Internal Disk Drive Command Transaction Timeout
PreviouslyPublishedAs 201706 Product Sun StorageTek 3510 FC Array Bug Id <SUNBUG: 4892830> Date of Resolved Release 21-AUG-2003 Impact Sun StorEdge 3510 Fiber Channel (FC) array may lose connectivity from the host or a logical drive initialization may fail. Contributing Factors This issue can occur in the following releases: SPARC Platform
This issue only occurs after an internal disk drive command transaction timeout (error code "62F") has been generated. To verify the firmware version, use the "telnet" or serial interface to the Sun StorEdge 3510 and select "View System Information" from the main menu. Symptoms Should the described issue occur, messages similar to the following are logged in the "/var/adm/messages" file, or in the Sun StorEdge 3510 event log: SCSI Drive ALERT: Unexpected Sense Received (62F) Also, a logical drive initialization may fail with the same timeout error as shown above.
Workaround There is no workaround. Please see the "Resolution" section below. Resolution This issue is addressed in the following release: SPARC Platform
Modification History References<SUNPATCH: 113723-05>Previously Published As 101321 Internal Comments
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 545913, 546566 Internal Resolution Patches 113723-05 Internal Sun Alert Kasp Legacy ID 101321, 56420 (Sun Alert) Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Pervasive Significant Change Date: 2003-08-21 Avoidance: Patch Responsible Manager: [email protected] Original Admin Info: This document has been imported from KMS Creator and may need adjustment before re-publishing. This imported document has been reviewed/adjusted by: Review Name: Review Date: Original KMS Creator attributes below: --- PLEASE DO NOT MAKE ANY CHANGES BELOW THIS LINE! --- Sun Alert ID: 56420 Synopsis: Sun StorEdge 3510 Fiber Channel Array May Lose In-band Connectivity After Generating an Internal Disk Drive Command Transaction Timeout Category: Availability Product: Sun StorEdge 3510 FC array BugIDs: 4892830 Avoidance: Patch State: Resolved Date Released: 21-Aug-2003 Date Closed: 21-Aug-2003 Date Modified: Escalation IDs: 545913, 546566 Pending Patches: Resolution Patches: 113723-05 FIN: FCO: Date Submitted: 18-Aug-2003 Submitter: [email protected] Responsible Engineer: [email protected] Responsible Manager: [email protected] CTE group: CPRE NWS US Responsible Writer: [email protected] Distribution: Public SunSolve Workflow History: WF State: Issued, 21-Aug-2003, Jeff Folla WF Note: Signoff approved by jonathan. Sent for release. WF State: Draft, 21-Aug-2003, Jeff Folla WF Note: sent for signoff WF State: Draft, 21-Aug-2003, Jeff Folla WF Note: sent for review 8/20 WF State: Draft, 18-Aug-2003, Jeff Folla WF Note: Article created. Exported from KMS Creator Sat May 21 09:03:03 2005 GMT, [email protected] Internal SA-FAB Eng Submission Sun StorEdge 3510 Fiber Channel Array May Lose In-band Connectivity After Generating an Internal Disk Drive Command Transaction Timeout Product_uuid 58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array ReferencesSUNPATCH:113723-05Attachments This solution has no attachment |
||||||||||||
|