Solution Type Sun Alert Sure Solution 1001018.1 : Sun Ultra 20 and Sun Fire X2100 With Specific Configurations May Experience "Silent Data Corruption"
PreviouslyPublishedAs 201344 Product Sun Fire X2100 Server Sun Ultra 20 Workstation Bug Id <SUNBUG: 6505640> Date of Workaround Release 01-FEB-2007 Date of Resolved Release 07-JUN-2007 Impact On Sun Ultra 20 and Sun Fire X2100 systems with Opteron RevE CPU running Linux Operating Systems and configured with at least 4 GB unbuffered memory (or more), a "silent data corruption" issue may occur. Contributing Factors This issue can occur on the following platforms:
with the following configuration:
Note: Systems with 1GB or 2GB unbuffered memory, and other Operating Systems (i.e. Sun Solaris) are not known to be affected by this issue. Symptoms The data corruption is typically a 4K block that is completely "nulled out", and sometimes random data are inside this 4K block. This may happen randomly to any files of any size, and there is no indication that data corruption has occurred. Workaround To work around the described issue, add the kernel parameter "iommu=soft" to the kernel command line in the grub boot loader configuration "/boot/grub/grub.conf". Note: Allowing the Linux Kernel to do the software bounce buffering has a performance hit of 15% to 20% for I/O operations. Resolution This issue is addressed on the following platforms:
The BIOS versions can be upgraded from the "Tools & Drivers" CD V1.7, available for download at: For Ultra 20: http://www.sun.com/desktop/workstation/ultra20/downloads.jsp For Sun Fire X2100: http://www.sun.com/servers/entry/x2100/downloads.jsp Modification History Date: 07-JUN-2007
Previously Published As 102790 Internal Comments Internal Contributor/submitter [email protected] Internal Eng Business Unit Group SSG WGS (Workgroup Systems) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-20850221 Internal Sun Alert Kasp Legacy ID 102790 Internal Sun Alert & FAB Admin Info Critical Category: Data Loss Significant Change Date: 2007-02-01, 2007-06-07 Avoidance: Upgrade Responsible Manager: [email protected] Original Admin Info: [WF 01-Feb-2007, dave m: send for release] [Resubmitted 29-Jan-2007, dave m: redraft issue] [WF 26-Jan-2007, dave m: draft created, sending for review] Product_uuid 28c0502a-fd60-11d9-a8ca-080020a9ed93|Sun Fire X2100 Server 372415be-961d-11d9-9adf-080020a9ed93|Sun Ultra 20 Workstation Attachments This solution has no attachment |
||||||||||||
|