Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000934.1 : On StorEdge 5210/5310 and StorageTek 5220/5320 NAS, a Panic May Occur When Backing Up Directories Containing Long File Names
PreviouslyPublishedAs 201250 Product Sun StorageTek 5310 NAS Appliance Sun StorageTek 5320 NAS Appliance Sun StorageTek 5220 NAS Appliance Sun StorageTek 5210 NAS Appliance Bug Id <SUNBUG: 6592230> Date of Resolved Release 30-OCT-2007 Impact The NAS head may panic resulting in the NDMP backup job not completing. Contributing Factors This issue occurs on the following releases:
This issue occurs during back up of directories consisting of files with long filenames. This issue is found in releases 4.21 M0 and 4.21 M1 of the StorageTek NAS OS. The NAS OS version can be found on the main panel of the Web Admin or by issuing the 'version' command from the console. Symptoms The NAS head will panic and reboot. The following can be observed in the "dbglog" file. eip 00000000 eflags 00010246 ..R...I..Z.P. vec 22 Stack overflow eax 00000000 ebx 00000000 ecx 003D6320 edx 00000000 edi 00000000 esi 00000000 ebp 00000000 esp 104B0050 000000 (bad) The following stack trace messages have also been observed in the system log. 08/13/07 11:30:17 I ndmp: [369][ndmpd_api_file_history_dir_v3:651]: 08/13/07 11:30:17 I ndmp: name "aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa ... 08/13/07 11:30:17 I ndmp: [369][ischngd:2039]: 08/13/07 11:30:17 I ndmp: stp is NULL 08/13/07 11:30:17 I isp1: SUSPEND I/O... 08/13/07 11:30:17 I isp2: SUSPEND I/O... 08/13/07 11:30:17 I isp3: SUSPEND I/O... 08/13/07 11:30:17 I isp4: SUSPEND I/O...
Workaround Do not back up directories consisting of files with long filenames until the resolution below can be implemented. Resolution This issue is addressed in the following releases:
The above patches deliver NAS OS 4.21 M2. See also, Sun StorageTek NAS OS Administration Guide (819-4284-11) Page 191: Upgrading NAS Software. References<SUNPATCH: 118216-14><SUNPATCH: 119351-13> <SUNPATCH: 119353-05> <SUNPATCH: 119352-08> Previously Published As 103133 Internal Comments Release 4.21 M2 (which contains the fix for this issue) has already been posted on sunsolve with the above patch numbers. A new release of 4.21 M2 is in the process of being posted on sunsolve. This release contains the same version of the NAS OS (4.21 M2) but is bundled with a new version of the CSM firmware. Root Cause - The cause of the panic is due to a buffer overrun during NDMP_FILE_HISTORY processing. The code has been modified to prevent overrunning the file name buffer while processing NDMP_FILE_HISTORY. Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Resolution Patches 118216-14, 119351-13, 119353-05, 119352-08 Internal Sun Alert Kasp Legacy ID 103133 Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Regression Significant Change Date: 2007-10-30 Avoidance: Patch Responsible Manager: [email protected] Original Admin Info: WF 26-Oct-2007 created and will send for review karen. Then i saw this was a patch regression and converted it to a Sun Alert. Releasing. Internal SA-FAB Eng Submission -------- Original Message -------- Subject: Draft Field Action Bulletin / Possible NAS panic when backing up directories containing, files with long filenames. Date: Thu, 25 Oct 2007 14:59:25 -0700 From: William Krier Reply-To: [email protected] To: [email protected] Field Action Bulletin (FAB) BLANK Submittal Template For Preliminary, Non-Hardware and Hardware FABs -- After following instructions for drafting a Field Action Bulletin, send this ASCII Text filled-in template to: [email protected] The email Subject line should be similar to the following: Draft Field Action Bulletin / Synopsis ... --------------------------------------------------------------- Synopsis: Possible NAS panic when backing up directories containing files with long filenames. Avoidance: [ ] Binary [ ] T-Patch [ ] Patch [ ] Firmware [ ] Hardware [X] Upgrade [ ] Workaround [ ] Reconfiguration [ ] Service Procedure [ ] None [ ] Hardware Replacement (Must follow SMI FCO Process) * * Note:Please follow the below link for details on how to submit an FCO; http://sunwebcollab.central.sun.com/gm/folder-1.11.811470 Implementation: [X] Reactive (Upon Failure) [ ] Controlled Proactive (H/W FABs require Customer List and Customer Letter) [ ] Mandatory (Requires Customer List and Customer Letter) Product: (Mktg Part Number / Description) StorEdge 5210 NAS StorEdge 5310 NAS StorageTek 5220 NAS StorageTek 5320 NAS Affected X-Options: (Xoption Part Number / Description) Affected Parts: (FRU/CRU Part Number / Description) Issue Description: Impact The NAS head will panic and reboot and the NDMP backup job will not complete. Contributing Factors The panic will occur if the backup job consists of directories that contain files with names longer than 255 characters. Symptoms The NAS head will panic and reboot. The following has been observed in the dbglog file. eip 00000000 eflags 00010246 ..R...I..Z.P. vec 22 Stack overflow eax 00000000 ebx 00000000 ecx 003D6320 edx 00000000 edi 00000000 esi 00000000 ebp 00000000 esp 104B0050 000000 (bad) FF 0x0 STACK TRACE: The following messages have also been observed in the system log. 08/13/07 11:30:17 I ndmp: [369][ndmpd_api_file_history_dir_v3:651]: 08/13/07 11:30:17 I ndmp: name "aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa 08/13/07 11:30:17 I ndmp: [369][ischngd:2039]: 08/13/07 11:30:17 I ndmp: stp is NULL 08/13/07 11:30:17 I isp1: SUSPEND I/O... 08/13/07 11:30:17 I isp2: SUSPEND I/O... 08/13/07 11:30:17 I isp3: SUSPEND I/O... 08/13/07 11:30:17 I isp4: SUSPEND I/O... Root Cause The cause of the panic is due to a buffer overrun during NDMP_FILE_HISTORY processing. The code has been modified to prevent overrunning the file name buffer while processing NDMP_FILE_HISTORY. The issue was resolved with a maintenance release of the StorageTek NAS OS. (4.21 M2) Corrective Action: Supported Workaround (if available) There is no workaround short of not backing up directories consisting of files with long filenames. Final Resolution Upgrade NAS OS to release 4.21 M2 Sun StorageTek NAS OS Administration Guide (819-4284-11) Page 191: Upgrading NAS Software Identification of Affected Parts (how to): This issue is found in releases 4.21 M0 and 4.21 M1 of the StorageTek NAS OS. The NAS OS version can be found on the main panel of the Web Admin or by issuing the 'version' command from the console. Hardware Remediation and Material Availability Details: (For Hardware FABs only) Not Applicable Comments: [List anything specific to this asset that isn't already listed above.] References: * BugID: 6592230 * Escalation ID: * Sun Alert: * Pending Patches: * Resolution Patches: StorageTek 5320 NAS 119352-09 StorageTek 5220 NAS 119353-06 StorEdge 5310 NAS 119351-14 StorEdge 5210 NAS 118216-14 * Other References: * Reference Manual: * Related URL(s): * ECO: * GSAP: * WW Stop Ship: * Radiance ID: Contacts: * Contributor: * Responsible Engineer: [email protected] * Responsible Manager: [email protected] * Business Unit Group: [ ] SSG WGS (Workgroup Systems) [ ] SSG NSN (Netra Systems and Networking) [ ] SSG ES (Enterprise Systems) [ ] SSG SW (Platform Software) [ ] SSG PNP (Processor) [ ] NSG (Network Systems Group) [X] NWS (Network Storage) [ ] OP/N1 RPE (Operating Platforms/N1 Revenue Product Engin.) [ ] JPSE (Java Platform Sustaining Engineering) [ ] JWSSE (Java Web Services Sustaining Engineering) [ ] USG (User Software Group) [ ] Other - Please specify Product_uuid 63654ce5-f88d-11d8-ab63-080020a9ed93|Sun StorageTek 5310 NAS Appliance 7656ca7b-9cd4-11da-85b4-080020a9ed93|Sun StorageTek 5320 NAS Appliance a656fa3d-fc97-11da-ac3d-080020a9ed93|Sun StorageTek 5220 NAS Appliance d4e4fc3d-7c3f-11d8-9e3a-080020a9ed93|Sun StorageTek 5210 NAS Appliance ReferencesSUNPATCH:118216-14SUNPATCH:119351-13 SUNPATCH:119352-08 SUNPATCH:119353-05 Attachments This solution has no attachment |
||||||||||||
|