Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000849.1 : SunFire V20z/ V40z With LSI MegaRaid (Cache Enabled) May Hang During I/O
PreviouslyPublishedAs 201130 Product Sun Fire V20z Server Sun Fire V40z Server Bug Id <SUNBUG: 6310808> Date of Workaround Release 06-DEC-2005 Date of Resolved Release 03-Apr-2008 Sun Fire V20z and V40z systems running Solaris 10 x86 with the LSI MegaRaid ... see below: 1. Impact Sun Fire V20z and V40z systems running Solaris 10 x86 with the LSI MegaRaid (SCSI) card and the accompanying "amr" driver (with the RAID caching feature enabled) may experience a hang or disruption of system I/O. 2. Contributing Factors This issue can occur on the following platforms:
Notes:
To determine if the system is using the "amr" driver, the following command can be run: # modinfo | grep -i amr 24 fffffffffbac0060 44b0 40 1 amr (AMR Driver V1.5) 3. Symptoms Should the described issue occur, "amr warning" messages similar to the following may be output to the "/var/adm/messages" log file and system console: Aug 13 14:26:45 va64-v40za amr: WARNING: timed out package detected, sc = ffffffff809fc000, pkt = ffffffff872f5080, index = 0, ac = ffffffff872f50e0 Aug 13 14:26:45 va64-v40za scsi: WARNING: /pci@0,0/pci1022,7450@a/pci1014,1a7@5/pci1000,532@0/sd@1,0 (sd17): Aug 13 14:26:45 va64-v40za SCSI transport failed: reason 'timeout': retrying command Aug 13 14:26:45 va64-v40za amr: WARNING: timed out package detected, sc = ffffffff809fc000, pkt = ffffffff83a0c040, index = 1, ac = ffffffff83a0c0a0 Aug 13 14:26:45 va64-v40za scsi: WARNING: /pci@0,0/pci1022,7450@a/pci1014,1a7@5/pci1000,532@0/sd@0,0 (sd1): Aug 13 14:26:45 va64-v40za SCSI transport failed: reason 'timeout': retrying command 4. Workaround To work around the described issue, use one of the following options: 1. Set the LSI MegaRaid caching feature to default values in the LSI MegaRaid configuration utility (CTRL-M). All defined LUNs should have the following caching parameter values: Read Policy = Normal Write Policy = Writethru Cache Policy = Direct I/O Note: Setting the caching parameters to default values may impact system I/O performance. Or: 2. Replace the the orginal LSI "amr" driver with the "lsimega" driver by downloading the file "solsimega.zip" from http://www.sun.com/download/products.xml?id=431fd1be Instructions for installing the new driver are included in the download file. (A Sun account for login is required to download this file). Note: The "lsimega" driver will be bundled with Solaris 10 x86 Update 1, scheduled for release in January 2006. 5. Resolution There are no further updates planned for this Sun Alert document. IfThis Sun Alert notification is being provided to you on an "AS IS" basis. This Sun Alert notification may contain information provided by third parties. The issues described in this Sun Alert notification may or may not impact your system(s). Sun makes no representations, warranties, or guarantees as to the information contained herein. ANY AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This Sun Alert notification contains Sun proprietary and confidential information. It is being provided to you pursuant to the provisions of your agreement to purchase services from Sun, or, if you do not have such an agreement, the Sun.com Terms of Use. This Sun Alert notification may only be used for the purposes contemplated by these agreements. Copyright 2000-2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A. All rights reserved. Modification History 03-Apr-2008: no further updates. Resolved Previously Published As 102059 Internal Comments Internal Contributor/submitter [email protected] Internal Eng Business Unit Group SSG WGS (Workgroup Systems) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-10468594 Internal Sun Alert Kasp Legacy ID 102059 Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> HA-Failure Significant Change Date: 2005-12-06 Avoidance: Workaround Responsible Manager: [email protected] Original Admin Info: [WF 05-Dec-2005, Dave M: xtra time give for multiple eng groups review, completed, sending for release] [WF 30-Nov-2005, Dave M: HOLIDAY break past, sending for review] [WF 22-Nov-2005, Dave M: draft created] Product_uuid 1acc55b3-4b82-11d8-99fc-080020a9ed93|Sun Fire V20z Server 4726b78d-56d2-11d8-9e3a-080020a9ed93|Sun Fire V40z Server Attachments This solution has no attachment |
||||||||||||
|