Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000753.1 : Certain FCAL Disk Drives For the Sun StorEdge T3+ Array May Go Offline
PreviouslyPublishedAs 201000 Product Sun StorageTek T3 Array Sun StorageTek T3+ Array Bug Id <SUNBUG: 5065023> Date of Resolved Release 30-NOV-2004 Impact In the Sun StorEdge T3+ array with drive firmware version 1504, disk types MAN3367FC (36.4GB FCAL) and MAN3735FC (73.4GB FCAL) may go offline. Contributing Factors This issue can occur on the following drive types:
on the following platform:
If a disk has gone offline, messages similar to the following will be reported in "/var/adm/messages": Nov 23 03:54:59 seine-t3-12 LPCT[1]: N: u1d07: Not ready on loop 1 Nov 23 03:55:00 seine-t3-12 LPCT[1]: N: u1d07: Not ready on loop 2 Nov 23 03:55:15 seine-t3-12 ISR1[1]: W: u1d07 SVD_PATH_FAILOVER: path_id = 0 Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18c9f4c) Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4 Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18c87ec) Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4 Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 sid 287454 stype 4003 disk error 4 Nov 23 03:55:47 seine-t3-12 ISR1[1]: W: u1d07 SVD_PATH_FAILOVER: path_id = 1 Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18c7b2c) Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4 Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18d010c) Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4 Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 sid 287454 stype 4003 disk error 4 Nov 23 03:56:05 seine-t3-12 ANNT[1]: W: u1d07: Failed Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 sid 287455 stype 4003 disk error 3 Nov 23 03:56:08 seine-t3-12 LPCT[1]: N: u1d07: Bypassed on loop 1 Nov 23 03:56:09 seine-t3-12 LPCT[1]: N: u1d07: Bypassed on loop 2 Nov 23 03:56:12 seine-t3-12 LT00[1]: N: u1d07 Reconstruction to standby disk started Nov 23 03:56:12 seine-t3-12 LT00[1]: N: u1d07 Reconstruction to standby drive failed Symptoms The drive will go offline and will no longer be available to the system. There are no other indications that this condition has occurred. Workaround There is no workaround for this issue. Please see the "Resolution" section below. Resolution This issue is resolved on the following drive types:
on the following platform:
Note: Only the single patch listed is necessary to resolve this issue, as the firmware for both the drives and controllers are embedded in the controller firmware on the T3+ platform. Modification History References<SUNPATCH: 115180-07>Previously Published As 101601 Internal Comments
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-4607316, 1-4556720, 1-4094779 Internal Resolution Patches 115180-07 Internal Sun Alert Kasp Legacy ID 101601, 57681 (Sun Alert) Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Pervasive Significant Change Date: 2004-11-30 Avoidance: Patch Responsible Manager: Verrapan Nachiappan Original Admin Info: This document has been imported from KMS Creator and may need adjustment before re-publishing. This imported document has been reviewed/adjusted by: Review Name: Review Date: Original KMS Creator attributes below: --- PLEASE DO NOT MAKE ANY CHANGES BELOW THIS LINE! --- Sun Alert ID: 57681 Synopsis: Certain FCAL Disk Drives For the Sun StorEdge T3+ Array May Go Offline Category: Availability Product: Sun StorEdge T3+ array, Disks: MAN3367FC (36.4GB FCAL), MAN3735FC (73.4GB FCAL) BugIDs: 5065023 Avoidance: Patch State: Resolved Date Released: 30-Nov-2004 Date Closed: 30-Nov-2004 Date Modified: Escalation IDs: 1-4607316, 1-4556720, 1-4094779 Pending Patches: Resolution Patches: 115180-07 FIN: FCO: Date Submitted: 15-Nov-2004 Submitter: [email protected] Responsible Engineer: [email protected] Responsible Manager: Verrapan Nachiappan CTE group: NWS Responsible Writer: [email protected] Distribution: Public SunSolve Workflow History: WF State: Issued, 30-Nov-2004, David Mariotto WF Note: sending for release WF State: Draft, 30-Nov-2004, David Mariotto WF Note: fianl approval OK, release today. WF State: Draft, 30-Nov-2004, David Mariotto WF Note: README is fixed, sent final copy to submitter for approval to release. WF State: Draft, 29-Nov-2004, David Mariotto WF Note: waiting for README to be fixed, then OK to release, review has been completed. WF State: Draft, 29-Nov-2004, David Mariotto WF Note: patch released, BugID not shown in patch README, email submitter for correction WF State: Draft, 22-Nov-2004, David Mariotto WF Note: patch is not found...hold WF State: Draft, 19-Nov-2004, David Mariotto WF Note: sending for review, 3pm WF State: Draft, 15-Nov-2004, David Mariotto WF Note: waiting response/comments from sub. eng WF State: Draft, 15-Nov-2004, David Mariotto WF Note: Article created. Exported from KMS Creator Sat May 21 09:14:35 2005 GMT, [email protected] Internal SA-FAB Eng Submission Certain FCAL Disk Drives For the Sun StorEdge T3+ Array May Go Offline Product_uuid 2a6d7d50-0a18-11d6-8e0b-f0bd33b24928|Sun StorageTek T3 Array 2a714b10-0a18-11d6-86e2-d56b387d4fbf|Sun StorageTek T3+ Array ReferencesSUNPATCH:115180-07Attachments This solution has no attachment |
||||||||||||
|