Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000678.1 : Deleting a StorEdge 6920 Snapshot Volume May Render the Primary Volume Inaccessible
PreviouslyPublishedAs 200890 Product Sun StorageTek 6920 System Bug Id <SUNBUG: 6273019> Date of Workaround Release 29-AUG-2005 Date of Resolved Release 20-OCT-2005 Impact When a snapshot volume is deleted from the Data Services Platform (DSP-1000) component of the Sun StorEdge (SE) 6920 array, the primary volume may become inaccessible. Contributing Factors This issue can occur on the following platforms:
Symptoms The primary volume will be unavailable to the host. This condition can be seen by running the format(1M) command, which will show the corresponding disk as inaccessible, as in the following example: before deletion of the snapshot volume: # format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c1t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107> /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w210000203784453e,0 1. c1t1d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107> /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000020378423ce,0 2. c9t600015D0000246000000000000000F0Dd0 <SUN-SE6920-0201 cyl 1278 alt 2 hd 32 sec 512> /scsi_vhci/ssd@g600015d0000246000000000000000f0d after deletion of the snapshot volume: # format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c1t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107> /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w210000203784453e,0 1. c1t1d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107> /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000020378423ce,0 2. c9t600015D0000246000000000000000F0Dd0 <drive type unknown> /scsi_vhci/ssd@g600015d0000246000000000000000f0d Workaround Access to the volume can be restored by unmapping and remapping the DSP volume to the host, as in the following example: # ./sscs unmap -S testdomain -i s4u-280ra-HBA0 volume volsource # ./sscs map -P readwrite -i s4u-280ra-HBA0 -S testdomain volume volsource (In the example above, the volume is "volsource," mapped to the host s4u-280ra-HBA0) Resolution This issue is resolved on the following platform:
For more information on all 6920 procedures and using the sscs(1M) commands, please see the "Sun StorEdge System Getting Started Guide" at http://docs.sun.com/app/docs?q=sscs and the "Sun StorEdge System 6920 Release Notes" at http://www.sun.com/products-n-solutions/hardware/docs/pdf/817-5229-14.pdf. Modification History Date: 20-OCT-2005 20-Oct-2005:
Previously Published As 101898 Internal Comments Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-9619015 Internal Sun Alert Kasp Legacy ID 101898 Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> HA-Failure Significant Change Date: 2005-08-29, 2005-10-20 Avoidance: Upgrade, Workaround Responsible Manager: [email protected] Original Admin Info: [WF 20-Oct-2005, Dave M: upgrade released, sending for rerelease] [WF 29-Aug-2005, Dave M: review complete, sending for release] [WF 26-Aug-2005, Dave M: sending for tech review] [WF 23-Aug-2005, Dave M: draft created] Product_uuid 67794720-356d-11d7-8ef2-ce2ac2bc9136|Sun StorageTek 6920 System Attachments This solution has no attachment |
||||||||||||
|