Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1000651.1
Update Date:2010-12-21
Keywords:

Solution Type  Sun Alert Sure

Solution  1000651.1 :   Sun StorageTek 6130/6140/6540 and Sun StorageTek Flexline 240/280/380 Arrays May Experience Loss of Network Access From Management Host  


Related Items
  • Sun Storage 6540 Array
  •  
  • Sun Storage Flexline 280 Array
  •  
  • Sun Storage 6130 Array
  •  
  • Sun Storage 6140 Array
  •  
  • Sun Storage Flexline 240 Array
  •  
  • Sun Storage Flexline 380 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
200861


Product
Sun StorageTek Flexline 380 Array
Sun StorageTek Flexline 240 Array
Sun StorageTek Flexline 280 Array
Sun StorageTek 6130 Array
Sun StorageTek 6140 Array
Sun StorageTek 6540 Array

Bug Id
<SUNBUG: 6583779>

Date of Workaround Release
04-SEP-2007

Date of Resolved Release
18-OCT-2007

Impact

Sun StorageTek 6130/6140/6540 and Sun StorageTek Flexline 240/280/380 arrays using either Common Array Manager (CAM) or SANtricity, may experience loss of network access from Management Host. Once the array network connection stops working, it is no longer possible for the Management Host to monitor or manage the array.

Access to data is not affected even if the Management Host is also a Data Host.


Contributing Factors

This issue can occur on the following platforms:

  • Sun StorageTek 6130 without array firmware 06.19.25.16
  • Sun StorageTek 6140 without array firmware 06.19.25.16
  • Sun StorageTek 6540 without array firmware 06.19.25.16
  • Sun StorageTek Flexline 240 without array firmware 06.19.25.26
  • Sun StorageTek Flexline 280 without array firmware 06.19.25.26
  • Sun StorageTek Flexline 380 without array firmware 06.19.25.26

with repeated gathering of supportData in Common Array Manager (CAM) or supportdata in SANtricity.


Symptoms

If the described issue occurs, from CAM's Browser User Interface Storage System Summary page, the Health of the array will say "Lost Communication" and it will not be possible to manage or monitor the array. In SANtriicty, you will be unable to connect. Attempts to ping either array controller will be unsuccessful. Attempts to use the Serial Service Interface appear to be unaffected.


Workaround

For immediate relief from this issue, power cycle the array.

If running any monitoring scripts in addition to the services offered by CAM or SANtricity that specifically call out the collection of the array supportData (see below), stop using them until a final resolution can be provided:

CAM - <fms_home>/bin/supportData -d <arrayname> -p <directory> -o <file_name>

    Solaris - fms_home = /opt/SUNWsefms
    Linux - fms_home = /opt/sun/cam/private/fms
    Windows - fms_home = C:\Program Files\Sun_Microsystems\StorageTek_Mgmt\Component\fms

SANtricity - <SMcli_home>\SMcli -n <arrayname> -c "save storageArray supportData file=\"supportdata.zip\";"

    Windows - SMcli_home = C:\Program Files\StorageManager\client
    Solaris/Linux - SMcli_home = /opt/SM9/client

A binary fix is available through normal support channels.


Resolution

This issue is addressed in the following releases:

  • Sun StorageTek 6130 with array firmware 06.19.25.16 or later
  • Sun StorageTek 6140 with array firmware 06.19.25.16 or later
  • Sun StorageTek 6540 with array firmware 06.19.25.16 or later
  • Sun StorageTek Flexline 240 with array firmware 06.19.25.26 or later
  • Sun StorageTek Flexline 280 with array firmware 06.19.25.26 or later
  • Sun StorageTek Flexline 380 with array firmware 06.19.25.26 or later

The firmware versions listed above are provided as part of the Sun StorageTek Common Array Manager 6.0 release bundle.



Modification History
Date: 18-OCT-2007
  • State: Resolved
  • Updated Contributing Factors and Resolution sections


Previously Published As
103059
Internal Comments


This issue can be verified by running "inetstatShow" from the debug port. In the output you should see a "LISTEN" state on TCP Proto for port 2463 in order for CAM or SANtricity to manage the array. If this port is not listening, you have encountered the issue.




    -> inetstatShow
    Active Internet connections (including servers)
    PCB Proto Recv-Q Send-Q Local Address Foreign Address (state)
    -------- ----- ------ ------ ------------------ ------------------ -------
    1ffcb538 TCP 0 0 192.168.64.10.513 192.168.64.150.1019 ESTABLISHED
    1ffcb220 TCP 0 0 0.0.0.0.2463 0.0.0.0.0 LISTEN
    1ffcb19c TCP 0 0 0.0.0.0.513 0.0.0.0.0 LISTEN
    1ffcb3ac UDP 0 0 0.0.0.0.2463 0.0.0.0.0
    1ffcb118 UDP 0 0 0.0.0.0.123 0.0.0.0.0
    1ffcb010 UDP 0 0 0.0.0.0.68 0.0.0.0.0
    value = 1 = 0x1
    ->


For CAM users, you will not be able to load the 6.19.25.14 firmware using the BUI, you will have to use "/opt/SUNWstksm/bin/csmservice" with the "-s" option.



For SANtricity users, there is no need to reload the NVSRAM file, only the 6.19.25.24 firmware.



Until the next version of CAM/SANtricity is released with this firmware, open a task to PTS to obtain it.


Internal Contributor/submitter
[email protected]

Internal Eng Business Unit Group
NWS (Network Storage)

Internal Eng Responsible Engineer
[email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Escalation ID
11059810, 65566078, 37850635, 37841306, 65548488

Internal Sun Alert Kasp Legacy ID
103059

Internal Sun Alert & FAB Admin Info
Critical Category: Availability ==> Pervasive
Significant Change Date: 2007-09-04, 2007-10-18
Avoidance: Upgrade, Workaround
Responsible Manager: [email protected]
Original Admin Info: [WF 18-Oct-2007, Jeff Folla: This is now resolved. Sent for re-release.]

[WF 04-Sep-2007, Jeff Folla: Sent for release.]

[WF 31-Aug-2007, Jeff Folla: Sent for review.]

Product_uuid
133a82c0-478b-11dc-9b8e-080020a9ed93|Sun StorageTek Flexline 380 Array
1fa39e9c-cff3-11da-a933-080020a9ed93|Sun StorageTek Flexline 240 Array
465d2e5d-41ff-11dc-9b8e-080020a9ed93|Sun StorageTek Flexline 280 Array
8252cb91-d771-11d8-ab52-080020a9ed93|Sun StorageTek 6130 Array
8ac7dca5-a8bd-11da-85b4-080020a9ed93|Sun StorageTek 6140 Array
e35cfcfc-a31a-11da-85b4-080020a9ed93|Sun StorageTek 6540 Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback