Solution Type Sun Alert Sure Solution 1000552.1 : Do Not Use Santricity Software to Manage the NAS SE5220/SE5310/SE5310C/SE5320/SE5320C Bundled Back-end Storage
PreviouslyPublishedAs 200698 Product Sun StorageTek 5320 NAS Appliance Sun StorageTek 5310 NAS Appliance Sun StorageTek 5220 NAS Appliance Bug Id <SUNBUG: 6559578> Date of Resolved Release 22-MAY-2007 Impact Using Santricity software to manage the NAS Sun StorEdgeTek 5220/5310/5310C/5320/5320C bundled back-end storage may result in data corruption and potential loss of data. Note: Santricity is not used to manage the back end storage ST6130 (CSM1) or ST6140 (CSM2) which was originally purchased with the Sun StorEdgeTek 5220/5310/5310/ST5320/5320c NAS heads. The RAID configuration information is stored differently than with Santricity, using the native in-band NAS RAID management GUI. Santricity will make adjustments when redistributing LUNs assigned to the NAS head (system board) resulting in possible data corruption and potential loss of data. Contributing Factors This issue can occur on the following platforms:
Note 1: This issue only occurs when using Santricity software to manage the bundled back end storage. Note 2: A gateway license key is required to access storage not bundled with the NAS head (system board). The gateway software key removes the ability for the NAS head to manage the un-bundled storage. Note 3: The gateway key will also prevent NAS head in-band management to the Sun StorEdge 6130/6140 arrays sold separately and attached to the NAS head with a gateway license key. Customers use the Sun CAMS software to manage the Sun StorEdge 6130/6140 arrays. Note 4: Customers with the StorageTek Flexline products can safely use Santricity along with a NAS gateway license key because all NAS head in-band management has been disabled and Santricity was originally bundled with the product. Symptoms Should the described issue occur, RAID configuration information and back-end storage features adjusted by Santricity while LUNs are assigned to the NAS head will cause NAS sfs2 filesytems to go offline and require a fsck(1M) to repair. Workaround To avoid the described issue, do not use Santricity to manage any back-end storage attached to the NAS SE5220/SE5310/SE5310C/SE5320/SE5320C which was originally bundled with the product. To work around this issue, use the native in-band NAS RAID management GUI stored on the NAS head compact flash. This is accessed by any web browser using the IP number assigned to the NAS. Example using ip number 192.168.0.50: http://192.168.0.50 RAID > Manage RAID
Resolution Please see the Relief/Workaround section above for the final resolution to this issue. Previously Published As 102915 Internal Comments Do not confuse Santricity and this alert with NRM (NAS Recovery Management). NRM is an internal NAS Sun management software used by Sun TSC service personal only for specific diagnostic purpose. This software is not permitted for resale. Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-21037694 Internal Sun Alert Kasp Legacy ID 102915 Internal Sun Alert & FAB Admin Info Critical Category: Data Loss Significant Change Date: 2007-05-22 Avoidance: Workaround Responsible Manager: [email protected] Original Admin Info: [WF 22-May-2007, Jeff Folla: Sent for release.] [WF19-May-2007, Jeff Folla: Sent for review.] [Resubmitted 19-May-2007, Jeff Folla: updated] [WF 11-May-2007, Jeff Folla: draft created] Product_uuid 27ca3082-cb13-11da-857a-080020a9ed93|Sun StorageTek 5320 NAS Appliance 63654ce5-f88d-11d8-ab63-080020a9ed93|Sun StorageTek 5310 NAS Appliance a656fa3d-fc97-11da-ac3d-080020a9ed93|Sun StorageTek 5220 NAS Appliance Attachments This solution has no attachment |
||||||||||||
|