Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1000551.1
Update Date:2011-01-05
Keywords:

Solution Type  Sun Alert Sure

Solution  1000551.1 :   Sun Fire X4100/X4200 Servers with AMD8131 Chipset May Require New I/O Card Drivers to Address AMD "errata 62"  


Related Items
  • Sun Fire X4100 Server
  •  
  • Sun Fire X4200 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
200697


Bug Id
<SUNBUG: 6426312>, <SUNBUG: 6534498>, <SUNBUG: 6483985>, <SUNBUG: 6399981>, <SUNBUG: 6531645>, <SUNBUG: 6532156>

Product
Sun Fire X4100 Server
Sun Fire X4200 Server

Date of Workaround Release
24-JUL-2007

Date of Resolved Release
29-Aug-2008

Under highly specific conditions, the AMD-8131 PCI-X tunnel may provide stale data to the PCI-X card:

Impact

Under highly specific conditions, the AMD-8131 PCI-X tunnel may provide stale data to the PCI-X card. The system will then become non-responsive, panic or target abort.

Note: AMD has issued "Errata #62" detailing this condition. This is available at:

http://www.amd.com/us-en/assets/content_type/white_papers_and_tech_docs/26310_AMD-8131_HyperTransport_PCI-X_Tunnel_Revision_Guide_rev_3_18.pdf
Contributing Factors

This issue can occur on the following platforms:

  • Sunfire X4100 servers with a 2/4Gb FC PCI-X HBA (both Emulex & QLogic)
  • Sunfire X4200 servers with a 2/4Gb FC PCI-X HBA (both Emulex & QLogic)

Note 1: This issue only occurs when using large block size during writes.

Note 2: Other PCI-X Cards affected by the AMD8131 Erratum 62 may include but is not limited to:

    10GBE (Kirkwood, X5544A-4)
    SCSI (Meteor, SGXPCI1SCSILM320-Z)
    Mellanox IB (IB-HCA, X1236A-Z)

 Symptoms

If the described issue occurs, data corruption, non-responsive system, target abort, and infinite retry of the PCI-X bus may be experienced.

Workaround

To work around the described issue, limit the transaction length via driver programming of the PCI-X card to 1K bytes or fewer.

Resolution

This issue is addressed in the following releases:

Emulex, BugID 6534498:

x86 Platform

  • Solaris 10 patch 120223-16 or later

Linux Platform

Linux 2.4 (Version 7.3.6_x1: RHEL 3, SLES 8)

  • lpfc_2.4_driver_kit-7.3.6_x1-1.tar.gz: Linux 2.4
  • PyramidE-fw.zip: Pyramid-E firmware for AMD 8131 fix
  • Rainbow-fw.zip: Rainbow firmware for AMD 8131 fix

Linux 2.6 (Version 8.0.16.32: RHEL 4u6+, SLES9 sp4+)

  • 8.0.16.27_x1.tar.gz: Linux 2.6

Windows Platform

  • Win 2K3 32-bit binary: elxstorinstall5120x3.zip
  • Win 2K3 64-bit binary: elxstorinstall7120x3.zip

The above fixes are available at:

QLogic BugID 6426312:

x86 Platform

  • Solaris 10 patch 119131-26 or later

Windows Platform

  • Win 2K3 32-bit/64-bit: PCI-X Hot Plug Driver Version 1.4.4.0 from AMD

Windows driver Version 1.4.4.0 is available for download at:

10GBE ethernet NIC: BugIDs 6531645 and 6399981 (Kirkwood, X5544A-4) ethernet NIC:

x86 Platform

  • Solaris 10 patch 125913-01 or later

Windows Platform

  • Win 2K3 32-bit/64-bit: PCI-X Hot Plug Driver Version 1.4.4.0 from AMD

Mellanox IB, BugID 6532156 (IB-HCA, X1236A-Z:

Windows Platform

  • Win 2K3 32-bit/64-bit: PCI-X Hot Plug Driver Version 1.4.4.0 from AMD

Drivers that address this issue are available through normal support channels for the following releases:

    (Emulex) Linux 2.6 (Version 8.1.10.5: RHEL 5u1+, SLES10 sp1+)
    (QLogic) Linux 2.4
    (QLogic) Linux 2.6
Modification History
29-Aug-2008: Updated Resolution section
State: Resolved


References

<SUNPATCH: 120223-16>
<SUNPATCH: 119131-26>
<SUNPATCH: 125913-01>

Previously Published As
103017
Internal Comments
Please send technical questions to the following email:
[email protected]
and CC the following persons:
Internal Contributor/Submitter
Internal Eng Responsible Engineer
Internal Services Knowledge Engineer
Internal Contributor/submitter
[email protected]
Internal Eng Responsible Engineer
[email protected]
Internal Services Knowledge Engineer
[email protected]
Internal Eng Business Unit Group
NSG (Network Systems Group)
Internal Resolution Patches
120223-16, 119131-26, 125913-01
Internal Sun Alert Kasp Legacy ID
103017

References

SUNPATCH:119131-26
SUNPATCH:120223-16
SUNPATCH:125913-01

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.