Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000551.1 : Sun Fire X4100/X4200 Servers with AMD8131 Chipset May Require New I/O Card Drivers to Address AMD "errata 62"
PreviouslyPublishedAs 200697 Bug Id <SUNBUG: 6426312>, <SUNBUG: 6534498>, <SUNBUG: 6483985>, <SUNBUG: 6399981>, <SUNBUG: 6531645>, <SUNBUG: 6532156> Product Sun Fire X4100 Server Sun Fire X4200 Server Date of Workaround Release 24-JUL-2007 Date of Resolved Release 29-Aug-2008 Under highly specific conditions, the AMD-8131 PCI-X tunnel may provide stale data to the PCI-X card: Impact Under highly specific conditions, the AMD-8131 PCI-X tunnel may provide stale data to the PCI-X card. The system will then become non-responsive, panic or target abort. Note: AMD has issued "Errata #62" detailing this condition. This is available at: http://www.amd.com/us-en/assets/content_type/white_papers_and_tech_docs/26310_AMD-8131_HyperTransport_PCI-X_Tunnel_Revision_Guide_rev_3_18.pdfContributing Factors This issue can occur on the following platforms:
Note 1: This issue only occurs when using large block size during writes. Note 2: Other PCI-X Cards affected by the AMD8131 Erratum 62 may include but is not limited to: 10GBE (Kirkwood, X5544A-4) Symptoms If the described issue occurs, data corruption, non-responsive system, target abort, and infinite retry of the PCI-X bus may be experienced. WorkaroundTo work around the described issue, limit the transaction length via driver programming of the PCI-X card to 1K bytes or fewer. ResolutionThis issue is addressed in the following releases: Emulex, BugID 6534498: x86 Platform
Linux Platform Linux 2.4 (Version 7.3.6_x1: RHEL 3, SLES 8)
Linux 2.6 (Version 8.0.16.32: RHEL 4u6+, SLES9 sp4+)
Windows Platform
The above fixes are available at: QLogic BugID 6426312: x86 Platform
Windows Platform
Windows driver Version 1.4.4.0 is available for download at: 10GBE ethernet NIC: BugIDs 6531645 and 6399981 (Kirkwood, X5544A-4) ethernet NIC: x86 Platform
Windows Platform
Mellanox IB, BugID 6532156 (IB-HCA, X1236A-Z: Windows Platform
Drivers that address this issue are available through normal support channels for the following releases: (Emulex) Linux 2.6 (Version 8.1.10.5: RHEL 5u1+, SLES10 sp1+)Modification History 29-Aug-2008: Updated Resolution section State: Resolved References<SUNPATCH: 120223-16><SUNPATCH: 119131-26> <SUNPATCH: 125913-01> Previously Published As 103017 Internal Comments Please send technical questions to the following email: [email protected] and CC the following persons: Internal Contributor/Submitter Internal Eng Responsible Engineer Internal Services Knowledge Engineer Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group NSG (Network Systems Group) Internal Resolution Patches 120223-16, 119131-26, 125913-01 Internal Sun Alert Kasp Legacy ID 103017 ReferencesSUNPATCH:119131-26SUNPATCH:120223-16 SUNPATCH:125913-01 Attachments This solution has no attachment |
||||||||||||
|