Solution Type Sun Alert Sure Solution 1000528.1 : StorageTek 5210/5220/5310/5320 NAS Tape Library with Multiple Drives Sharing the Same Target IDs May Lose Drive Visibility to the NDMP Backup Module
PreviouslyPublishedAs 200673 Product Sun StorageTek 5310 NAS Appliance Sun StorageTek 5320 NAS Appliance Sun StorageTek 5220 NAS Appliance Sun StorageTek 5210 NAS Appliance Bug Id <SUNBUG: 6547423> Date of Workaround Release 01-JUN-2007 Date of Resolved Release 24-JUL-2007 Impact Tape drives may not be available for NDMP backups and restores. Contributing Factors This issue can occur in the following products:
This issue was introduced with the above firmware and prior releases are not affected. If multiple drives share the same scsi target ID (from the host's point of view). It this occurs only one drive will be visible to the backup software. Hooking a SCSI tape library with multiple drives to an FC HBA via an FC/SCSI switch is such an example. To determine an affected system, issue the 'version' cli command.The output will be similar to one of the following: NAS>version StorageTek Model 5210 NAS S/N SE52102005102101 Version 4.21 M0 (Build 123) StorageTek Model 5310 NAS S/N SE53102005102101 Version 4.21 M0 (Build 123) StorageTek Model 5310C NAS S/N SE5310C2005102101-H1 Version 4.21 M0 (Build 123) StorageTek Model 5220 NAS S/N SE52202005102101 Version 4.21 M0 (Build 123) StorageTek Model 5320 NAS S/N SE53202005102101 Version 4.21 M0 (Build 123) StorageTek Model 5320C NAS S/N SE5310C2005102101-H1 Version 4.21 M0 (Build 123)
Symptoms The command "ndmp devices" only shows the tape library and one tape drive, while multiple drives are expected. An error log similar to the following one will show up in the NAS syslog: 04/17/07 12:32:38 E scsi_sasd_symlink: /dev/isp2t7D1: error 17
Workaround Do not install NAS OS release 4.21 M0 as delivered in the above patches. Important Note: The above firmware patches mentioned in the Contributing Factors are still available on SunSolve. It was determined that due to other advantages of these patches they were not withdrawn from SunSolve. Resolution This issue is addressed in the following releases:
Modification History Date: 24-JUL-2007
References<SUNPATCH: 118216-13><SUNPATCH: 119351-12> <SUNPATCH: 119353-04> <SUNPATCH: 119352-07> Previously Published As 102944 Internal Comments NOTE: all questions on this Sun Alert should be directed to [email protected]. The software release with the fix is not yet available. The version will be 4.21 M1. Since the fix is not released, we do not have patch numbers for Pending Patches above. Internal Contributor/submitter [email protected] Internal Eng Business Unit Group SSG ES (Enterprise Systems) Internal Eng Responsible Engineer [email protected], [email protected] Internal Services Knowledge Engineer [email protected] Internal Resolution Patches 118216-13, 119351-12, 119353-04, 119352-07 Internal Sun Alert Kasp Legacy ID 102944 Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Regression Significant Change Date: 2007-06-01, 2007-07-24 Avoidance: Patch Responsible Manager: [email protected] Original Admin Info: null Internal SA-FAB Eng Submission -------- Original Message -------- Subject: Draft Sun Alert: Bug ID 6547423, tape library with multiple tape drives sharing the same target ids is connected to an ST5xxx NAS Date: Wed, 30 May 2007 14:34:36 -0600 From: [email protected] To: Karen Edwards Synopsis: When a tape library with multiple tape drives sharing the same target ids is connected to an ST5xxx NAS, only one drive may be visible to the NDMP backup module. Category: [x ] Availability [ ] Diagnosis [ ] HA-Failure [ ] Pervasive (Bug experienced by four or more external customers) [ x] Regression [ ] Severe [ ] Data Loss [ ] Security Product: StorEdge 5210 NAS StorEdge 5310 NAS StorageTek 5220 NAS StorageTek 5320 NAS BugID: 6547423 Avoidance: [ ] Workaround [ ] Binary [ ] T-Patch [ ] Patch [ x] Upgrade [ ] FCO [ ] HW [x ] None (Preliminary) State: [x ] Preliminary [ ] Workaround [x ] Resolved 1. Impact: The un-discovered tape drives are not available for NDMP backup/restore. 2. Contributing Factors: If multiple drives share the same scsi target ID (from the host's point of view), only one drive will be visible to the backup software. Hooking a SCSI tape library with multiple drives to an FC HBA via an FC/SCSI switch is such an example. 3. Symptoms: Command "ndmp devices" only shows the tape library and one tape drive, while multiple drives are expected. An error log similar to the following one will show up in the NAS syslog: 04/17/07 12:32:38 E scsi_sasd_symlink: /dev/isp2t7D1: error 17 4. Relief/Workaround: Do not install NAS OS release 4.21 or Upgrade NAS OS to release 4.21 M1 5. Resolution: Upgrade NAS OS to release 4.21 M1 6. Internal Section: Escalation IDs: N/A Pending Patches: The affected software release is 4.21 B123 (for all platforms) with the following patch ids: StorEdge 5210 NAS software update - 118216-12 StorEdge 5310 NAS software update - 119351-11 StorageTek 5220 NAS software update - 119353-03 StorageTek 5320 NAS software update - 119352-06 The software release with the fix is not yet available. The version will be 4.21 M1 Since the fix is not released, we do not have patch ids. Normally the last number of the patch id is incremented by one (ie for 5320 it would be 119352-07). However this could change if for some reason there is a problem with the patch release process and a respin of the patch is required. Resolution Patches: FIN: N/A FCO: N/A Submitter: [email protected] Responsible Engineer: [email protected] Responsible Manager: [email protected] PTS/Engineering organization: NAS/Systems [ ] SSG WGS (Workgroup Systems) [ ] SSG NSN (Netra Systems and Networking) [ x] SSG ES (Enterprise Systems) (also used for OPL Systems) Distribution: [x ] Public SunSolve [ ] Contract SunSolve Comments: PTS Reviewer (approved by): Peter Quinto -------- Original Message -------- Subject: Re: [Fwd: Re: Draft Sun Alert: Bug ID 6547423, tape library with multiple tape drives sharing the same target ids is connected to an ST5xxx NAS] Date: Wed, 30 May 2007 15:29:50 -0700 From: William Krier Reply-To: [email protected] To: [email protected] CC: Peter Quinto References: <[email protected]> Cliff, The only affected patches are: StorEdge 5210 NAS software update - 118216-12 StorEdge 5310 NAS software update - 119351-11 StorageTek 5220 NAS software update - 119353-03 StorageTek 5320 NAS software update - 119352-06 Customers can determine if they are running the affected patches by issuing the 'version' cli command. The output will be similar to one of the following on affected systems NAS>version StorageTek Model 5210 NAS S/N SE52102005102101 Version 4.21 M0 (Build 123) StorageTek Model 5310 NAS S/N SE53102005102101 Version 4.21 M0 (Build 123) StorageTek Model 5310C NAS S/N SE5310C2005102101-H1 Version 4.21 M0 (Build 123) StorageTek Model 5220 NAS S/N SE52202005102101 Version 4.21 M0 (Build 123) StorageTek Model 5320 NAS S/N SE53202005102101 Version 4.21 M0 (Build 123) StorageTek Model 5320C NAS S/N SE5310C2005102101-H1 Version 4.21 M0 (Build 123) --Bill Product_uuid 63654ce5-f88d-11d8-ab63-080020a9ed93|Sun StorageTek 5310 NAS Appliance 7656ca7b-9cd4-11da-85b4-080020a9ed93|Sun StorageTek 5320 NAS Appliance a656fa3d-fc97-11da-ac3d-080020a9ed93|Sun StorageTek 5220 NAS Appliance d4e4fc3d-7c3f-11d8-9e3a-080020a9ed93|Sun StorageTek 5210 NAS Appliance ReferencesSUNPATCH:118216-13SUNPATCH:119351-12 SUNPATCH:119352-07 SUNPATCH:119353-04 Attachments This solution has no attachment |
||||||||||||
|