Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000526.1 : Upgrading Certain Sun Fire/Enterprise or Netra Systems to Firmware 6.4.4 Prior to OS Boot May Corrupt the Service Processor
PreviouslyPublishedAs 200669 Bug Id <SUNBUG: 6564792> Date of Workaround Release 19-JUL-2007 Date of Resolved Release 10-SEP-2007 Impact Installing firmware version 6.4.4 on new SunFire/Enterprise T1000 and T2000, Netra T2000 and Netra CP3060 servers prior to booting to the OS will cause the service processor to become corrupted. Once the service processor is corrupted, it goes into a continuous boot loop that cannot be broken without replacing the service processor. Contributing Factors This issue can occur on the following platforms: SPARC Platform
if the upgrade to firmware 6.4.4 has been performed prior to booting to the OS. Notes:
The series of events leading to this issue are as follows:
Symptoms After upgrading/flashupdate to firmware 6.4.4, then running 'resetsc' on the service processor, the system will go into a continuous boot loop. The sequence is as follows:
Workaround On a new system, upgrading the firmware directly to 6.4.6 (from 6.3 or earlier) will prevent this issue altogether. To avoid this issue when upgrading the firmware to 6.4.4 on a new system, make sure the system has first been booted completely to the OS prior to the firmware upgrade. (It is not required to run POST). Then the flashupdate to firmware 6.4.4 may be performed. Resolution This issue is addressed on the following platforms: SPARC Platform
Modification History Date: 10-SEP-2007
Product Sun Fire T2000 Server Sun Fire T1000 Server Sun Netra T2000 Server Netra CP3060 Board References<SUNPATCH: 126399-02><SUNPATCH: 126400-02> <SUNPATCH: 126401-02> <SUNPATCH: 126402-02> Previously Published As 103010 Internal Comments Internal Contributor/submitter [email protected] Internal Eng Business Unit Group SSG SW (Platform Software) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-21891401, 1-21908506 Internal Resolution Patches 126399-02, 126400-02, 126401-02, 126402-02 Internal Sun Alert Kasp Legacy ID 103010 Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Severe, Availability ==> Regression Significant Change Date: 2007-07-19, 2007-09-10 Avoidance: Patch Responsible Manager: [email protected] Original Admin Info: [WF 10-Sep-2007, dave m: patch released, rerelease] [WF 19-Jul-2007, dave m: review completed, send to publish] [WF 18-Jul-2007, dave m: draft created, sending for review] Product_uuid 41b7bc41-2581-11da-99bc-080020a9ed93|Sun Fire T2000 Server 79ad78b9-961d-11d9-9adf-080020a9ed93|Sun Fire T1000 Server 7ba6ed6a-ec35-11da-ac3d-080020a9ed93|Netra T2000 Server affee54e-2313-11db-a023-080020a9ed93|Netra CP3060 Board ReferencesSUNPATCH:126399-02SUNPATCH:126400-02 SUNPATCH:126401-02 SUNPATCH:126402-02 ReferencesSUNPATCH:126399-02SUNPATCH:126400-02 SUNPATCH:126401-02 SUNPATCH:126402-02 Attachments This solution has no attachment |
||||||||||||
|