Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000000.1 : SCSI Enclosure Services (SES) Devices on a Sun Storage 3510 Array May Experience Unexpected Behavior
PreviouslyPublishedAs 200001
Applies to:Sun Storage 3510 FC ArrayAll Platforms DescriptionDescription SCSI Enclosure Services (SES) Devices on a Sun Storage 3510 array may experience unexpected behavior such as random LED activity, invalid events in the event log, and possible disk failures. Access from the Sun Storage 3510 array to the host may or may not be impacted when this behavior is observed. Likelihood of OccurrenceThis issue can occur on the following platform: SPARC Platform
Possible SymptomsSymptoms Should the described issue occur, the Sun Storage 3510 array may log critical events about battery, voltage, temperature and/or path failure. At the same time, the controller and drive LEDs may be inconsistent, such as all green, all amber, all OFF, or some combination. Workaround or ResolutionWorkaround To recover from the described issue, power cycle the SE3510 array. This should resolve the availability issues, and return LEDs to their normal state. PatchesPatches-Sun Storage 3510 FC Array SES Firmware 1080 only Release: 113662-01. While this provides an SES firmware only patch, it is recommended to upgrade to the latest SES revision (currently 1106) included in the Sun Storage 3510 FC Array Firmware Release: 113723-21. Modification HistoryReferencesSUNPATCH:113662-01Attachments This solution has no attachment |
||||||||||||
|