Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1000000.1
Update Date:2011-02-21
Keywords:

Solution Type  Sun Alert Sure

Solution  1000000.1 :   SCSI Enclosure Services (SES) Devices on a Sun Storage 3510 Array May Experience Unexpected Behavior  


Related Items
  • Sun Storage 3510 FC Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
200001


Applies to:

Sun Storage 3510 FC Array
All Platforms

Description


Description

SCSI Enclosure Services (SES) Devices on a Sun Storage  3510 array may experience unexpected behavior such as random LED activity, invalid events in the event log, and possible disk failures. Access from the Sun Storage 3510 array to the host may or may not be impacted when this behavior is observed.

Likelihood of Occurrence

This issue can occur on the following platform:

SPARC Platform

  • Sun Storage 3510 FC array at an SES Firmware lower than 1080.

Possible Symptoms


Symptoms

Should the described issue occur, the Sun Storage 3510 array may log critical events about battery, voltage, temperature and/or path failure. At the same time, the controller and drive LEDs may be inconsistent, such as all green, all amber, all OFF, or some combination.

Workaround or Resolution


Workaround

To recover from the described issue, power cycle the SE3510 array. This should resolve the availability issues, and return LEDs to their normal state.

Patches

Patches

-Sun Storage 3510 FC Array SES Firmware 1080 only Release: 113662-01. While this provides an SES firmware only patch, it is recommended to upgrade to the latest SES revision (currently 1106) included in the Sun Storage 3510 FC Array Firmware Release: 113723-21.

Modification History

References

SUNPATCH:113662-01

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.